The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Transcatheter Aortic Valve Implantation: Durability of Clinical and Hemodynamic Outcomes Beyond 3 Years in a Large Patient Cohort
Abstract
Background—: Although short- and medium-term outcomes after transcatheter aortic valve implantation are encouraging, long-term data on valve function and clinical outcomes are limited. Methods and Results—: Consecutive high-risk patients who had been declined as surgical candidates because of comorbidities but who underwent successful transcatheter aortic valve implantation with a balloon-expandable valve between January 2005 and December 2006 and survived past 30 days were assessed. Clinical, echocardiographic, and computed tomographic follow-up examinations were performed. Seventy patients who underwent successful procedures and survived longer than 30 days were evaluated at a minimum follow-up of 3 years. At a median follow-up of 3.7 years (interquartile range 3.4 to 4.3 years), survival was 57%. Survival at 1, 2, and 3 years was 81%, 74%, and 61%, respectively. Freedom from reoperation was 98.5% (1 patient with endocarditis). During this early procedural experience, 11 patients died within 30 days, and 8 procedures were unsuccessful. When these patients were included, overall survival was 51%. Transaortic pressure gradients increased from 10.0 mm Hg (interquartile range 8.0 to 12.0 mm Hg) immediately after the procedure to 12.1 mm Hg (interquartile range 8.6 to 16.0 mm Hg) after 3 years ( P =0.03). Bioprosthetic valve area decreased from a mean of 1.7±0.4 cm 2 after the procedure to 1.4±0.3 cm 2 after 3 years ( P <0.01). Aortic incompetence after implantation was trivial or mild in 84% of cases and remained unchanged or improved over time. There were no cases of structural valvular deterioration, stent fracture, deformation, or valve migration. Conclusions—: Transcatheter aortic valve implantation demonstrates good medium- to long-term durability and preserved hemodynamic function, with no evidence of structural failure. The procedure appears to offer an adequate and lasting resolution of aortic stenosis in selected patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frailty in Older Adults: Evidence for a Phenotype
Fried, L. P., Tangen, C. M., Walston, J., Newman, A. B., Hirsch, C., Gottdiener, J., Seeman, T., Tracy, R., Kop, W. J., Burke, G., et al. (2001) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/56.3.m146 · Cited by 24,907
Levey, A. S., Bosch, J. P., Lewis, J. B., Greene, T., Rogers, N., Roth, D., & for the Modification of Diet in Renal Disease Study Group* (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-6-199903160-00002 · Cited by 15,079
Zoghbi, W. A., Enriquez-Sarano, M., Foster, E., Grayburn, P. A., Kraft, C. D., Levine, R. A., Nihoyannopoulos, P., Otto, C. M., Quinones, M. A., Rakowski, H., et al. (2003) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(03)00335-3 · Cited by 4,044
Webb, J. G., Pasupati, S., Humphries, K., Thompson, C., Altwegg, L., Moss, R., Sinhal, A., Carere, R. G., Munt, B., Ricci, D., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.698258 · Cited by 1,016
Self-citationPercutaneous Aortic Valve Implantation Retrograde From the Femoral Artery
Webb, J. G., Chandavimol, M., Thompson, C. R., Ricci, D. R., Carere, R. G., Munt, B. I., Buller, C. E., Pasupati, S., & Lichtenstein, S. (2006) · Circulation · doi:10.1161/circulationaha.105.582882 · Cited by 900
Self-citationEvaluation of aortic insufficiency by Doppler color flow mapping
Perry, G. J., Helmcke, F., Nanda, N. C., Byard, C., & Soto, B. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80254-1 · Cited by 882
Treatment of Calcific Aortic Stenosis With the Percutaneous Heart Valve
Cribier, A., Eltchaninoff, H., Tron, C., Bauer, F., Agatiello, C., Nercolini, D., Tapiero, S., Litzler, P.-Y., Bessou, J.-P., & Babaliaros, V. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.01.049 · Cited by 715
Transcatheter Aortic Valve Implantation: Impact on Clinical and Valve-Related Outcomes
Webb, J. G., Altwegg, L., Boone, R. H., Cheung, A., Ye, J., Lichtenstein, S., Lee, M., Masson, J. B., Thompson, C., Moss, R., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.837807 · Cited by 589
Self-citationTransapical Transcatheter Aortic Valve Implantation in Humans: Initial Clinical Experience
Lichtenstein, S. V., Cheung, A., Ye, J., Thompson, C. R., Carere, R. G., Pasupati, S., & Webb, J. G. (2006) · Circulation · doi:10.1161/circulationaha.106.632927 · Cited by 561
Self-citationNoninvasive Evaluation of the Aortic Root With Multislice Computed Tomography
Tops, L. F., Wood, D. A., Delgado, V., Schuijf, J. D., Mayo, J. R., Pasupati, S., Lamers, F. P. L., van der Wall, E. E., Schalij, M. J., Webb, J. G., et al. (2008) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2007.12.006 · Cited by 518
Self-citationGuidelines for Reporting Mortality and Morbidity After Cardiac Valve Interventions
Akins, C. W., Miller, D. C., Turina, M. I., Kouchoukos, N. T., Blackstone, E. H., Grunkemeier, G. L., Takkenberg, J. J. M., David, T. E., Butchart, E. G., Adams, D. H., et al. (2008) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2007.12.082 · Cited by 481
Clavel, M.-A., Webb, J. G., Pibarot, P., Altwegg, L., Dumont, E., Thompson, C., De Larochellière, R., Doyle, D., Masson, J.-B., Bergeron, S., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.01.060 · Cited by 389
Self-citationNg, A. C. T., Delgado, V., van der Kley, F., Shanks, M., van de Veire, N. R. L., Bertini, M., Nucifora, G., van Bommel, R. J., Tops, L. F., de Weger, A., et al. (2010) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.109.885152 · Cited by 373
Jamieson, W. R. E., Rosado, L. J., Munro, A. I., Gerein, A. N., Burr, L. H., Miyagishima, R. T., Janusz, M. T., & Tyers, G. F. O. (1988) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(10)65888-2 · Cited by 191
Role of Multislice Computed Tomography in Transcatheter Aortic Valve Replacement
Wood, D. A., Tops, L. F., Mayo, J. R., Pasupati, S., Schalij, M. J., Humphries, K., Lee, M., Al Ali, A., Munt, B., Moss, R., et al. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2009.01.034 · Cited by 176
Self-citationLate incidence and determinants of reoperation in patients with prosthetic heart valves
Ruel, M. (2004) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2003.12.013 · Cited by 170
Ye, J., Cheung, A., Lichtenstein, S. V., Pasupati, S., Carere, R. G., Thompson, C., Sinhal, A. R., & Webb, J. G. (2006) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2006.10.023 · Cited by 156
Self-citationUnoperated Patients With Severe Aortic Stenosis
Bach, D. S., Cimino, N., & Deeb, G. M. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.08.011 · Cited by 154
Bleiziffer, S., Ruge, H., Mazzitelli, D., Schreiber, C., Hutter, A., Laborde, J., Bauernschmitt, R., & Lange, R. S. (2009) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2008.12.041 · Cited by 133
A New Transcatheter Aortic Valve and Percutaneous Valve Delivery System
Webb, J. G., Altwegg, L., Masson, J., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.075 · Cited by 126
Self-citationParavalvular regurgitation one year after transcatheter aortic valve implantation
Rajani, R., Kakad, M., Khawaja, M. Z., Lee, L. S., James, R., Saha, M., & Hildick‐Smith, D. (2009) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.22399 · Cited by 81
Kojodjojo, P., Gohil, N., Barker, D., Youssefi, P., Salukhe, T. V., Choong, A. M. T. L., Koa‐Wing, M., Bayliss, J., Hackett, D. R., & Khan, M. A. (2008) · QJM · doi:10.1093/qjmed/hcn052 · Cited by 78
Lu, T.-L. C., Rizzo, E., Marques-Vidal, P. M., von Segesser, L. K., Dehmeshki, J., & Qanadli, S. D. (2009) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1510/icvts.2009.216275 · Cited by 50
Kulik, A., Masters, R. G., Bédard, P., HENDRY, P. J., Lam, B.-K., Rubens, F. D., Mesana, T. G., & Ruel, M. (2009) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2009.06.051 · Cited by 31
Cited by
Guidelines on the management of valvular heart disease (version 2012)
Authors/Task Force Members, Vahanian, A., Alfieri, O., Andreotti, F., Antunes, M. J., Barón-Esquivias, G., Baumgartner, H., Borger, M. A., Carrel, T. P., De Bonis, M., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs109 · Cited by 3,559
Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement
Kodali, S. K., Williams, M. R., Smith, C. R., Svensson, L. G., Webb, J. G., Makkar, R. R., Fontana, G. P., Dewey, T. M., Thourani, V. H., Pichard, A. D., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1200384 · Cited by 2,282
Self-citationGuidelines on the management of valvular heart disease (version 2012)
Authors/Task Force Members, Vahanian, A., Alfieri, O., Andreotti, F., Antunes, M. J., Barón-Esquivias, G., Baumgartner, H., Borger, M. A., Carrel, T. P., De Bonis, M., et al. (2012) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezs455 · Cited by 2,009
Mack, M. J., Leon, M. B., Smith, C. R., Miller, D. C., Moses, J. W., Tuzcu, E. M., Webb, J. G., Douglas, P. S., Anderson, W. N., Blackstone, E. H., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60308-7 · Cited by 1,739
Self-citationTranscatheter Aortic-Valve Replacement for Inoperable Severe Aortic Stenosis
Makkar, R. R., Fontana, G. P., Jilaihawi, H., Kapadia, S., Pichard, A. D., Douglas, P. S., Thourani, V. H., Babaliaros, V. C., Webb, J. G., Herrmann, H. C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1202277 · Cited by 1,342
Self-citation
Metadata
- Authors
- Gurvitch, R., Wood, D. A., Tay, E. L., Leipsic, J., Ye, J., Lichtenstein, S. V., Thompson, C. R., Carere, R. G., Wijesinghe, N., Nietlispach, F., Boone, R. H., Lauck, S., Cheung, A., & Webb, J. G.
- Venue
- Circulation
- Published
- 2010-09-28
- Volume
- 122
- Issue
- 13
- Pages
- 1319-1327
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2023617433
- Cited by
- 258
- References
- 24
- FWCI
- 32.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.