Novel Single-Chain Antibody-Targeted Microbubbles for Molecular Ultrasound Imaging of Thrombosis: Validation of a Unique Noninvasive Method for Rapid and Sensitive Detection of Thrombi and Monitoring of Success or Failure of Thrombolysis in Mice

Open access
Wang, Xiaowei, Hagemeyer, Christoph E., Hohmann, Jan David, Leitner, Ephraem, Armstrong, Paul C., Jia, Fu, Olschewski, Manfred, Needles, Andrew, Peter, Karlheinz, Ahrens, Ingo·2012·Circulation

Abstract

Background—: Molecular imaging is a fast emerging technology allowing noninvasive detection of vascular pathologies. However, imaging modalities offering high resolution currently do not allow real-time imaging. We hypothesized that contrast-enhanced ultrasound with microbubbles (MBs) selectively targeted to activated platelets would offer high-resolution, real-time molecular imaging of evolving and dissolving arterial thrombi. Methods and Results—: Lipid-shell based gas-filled MBs were conjugated to either a single-chain antibody specific for activated glycoprotein IIb/IIIa via binding to a Ligand-Induced Binding Site (LIBS-MBs) or a nonspecific single-chain antibody (control MBs). Successful conjugation was assessed in flow cytometry and immunofluorescence double staining. LIBS-MBs but not control MBs strongly adhered to both immobilized activated platelets and microthrombi under flow. Thrombi induced in carotid arteries of C57Bl6 mice in vivo by ferric chloride injury were then assessed with ultrasound before and 20 minutes after MB injection through the use of gray-scale area intensity measurement. Gray-scale units converted to decibels demonstrated a significant increase after LIBS-MB but not after control MB injection (9.55±1.7 versus 1.46±1.3 dB; P <0.01). Furthermore, after thrombolysis with urokinase, LIBS-MB ultrasound imaging allows monitoring of the reduction of thrombus size ( P <0.001). Conclusion—: We demonstrate that glycoprotein IIb/IIIa–targeted MBs specifically bind to activated platelets in vitro and allow real-time molecular imaging of acute arterial thrombosis and monitoring of the success or failure of pharmacological thrombolysis in vivo.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.111.030312

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 163

Metadata

Authors
Wang, X., Hagemeyer, C. E., Hohmann, J. D., Leitner, E., Armstrong, P. C., Jia, F., Olschewski, M., Needles, A., Peter, K., & Ahrens, I.
Venue
Circulation
Published
2012-06-26
Volume
125
Issue
25
Pages
3117-3126
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2160512390
Cited by
163
References
5
FWCI
9.59
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Novel Single-Chain Antibody-Targeted Microbubbles for Molecular Ultrasound Imaging of Thrombosis: Validation of a Unique Noninvasive Method for Rapid and Sensitive Detection of Thrombi and Monitoring of Success or Failure of Thrombolysis in Mice. https://app.cochat.ai/papers/10.1161/circulationaha.111.030312
The paper
Wang, X., Hagemeyer, C. E., Hohmann, J. D., Leitner, E., Armstrong, P. C., Jia, F., Olschewski, M., Needles, A., Peter, K., & Ahrens, I. (2012). Novel Single-Chain Antibody-Targeted Microbubbles for Molecular Ultrasound Imaging of Thrombosis: Validation of a Unique Noninvasive Method for Rapid and Sensitive Detection of Thrombi and Monitoring of Success or Failure of Thrombolysis in Mice. Circulation. https://doi.org/10.1161/circulationaha.111.030312

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.