The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Timing, Predictive Factors, and Prognostic Value of Cerebrovascular Events in a Large Cohort of Patients Undergoing Transcatheter Aortic Valve Implantation
Abstract
Background—: The objective of this study was to evaluate the timing, predictive factors, and prognostic value of cerebrovascular events (CVEs) after transcatheter aortic valve implantation. Methods and Results—: The study included 1061 consecutive patients who underwent transcatheter aortic valve implantation with a balloon-expandable (64%) or self-expandable (36%) valve. CVEs were classified as acute (≤24 hours), subacute (1–30 days), or late (>30 days). CVEs occurred in 54 patients (5.1%; stroke, 4.2%) within 30 days after transcatheter aortic valve implantation (acute in 54% of cases). The predictors of acute CVEs were balloon postdilation of the valve prosthesis (odds ratio, 2.46; 95% confidence interval,1.07–5.67) and valve dislodgment/embolization (odds ratio, 4.36; 95% CI, 1.21–15.69); new-onset atrial fibrillation (odds ratio, 2.76; 95% CI, 1.11–6.83) was a predictor of subacute CVEs. Late CVEs occurred in 35 patients (3.3%; stroke, 2.1%) at a median follow-up of 12 months (3–23 months). The predictors of late CVEs were chronic atrial fibrillation (2.84; 95% CI, 1.46–5.53), peripheral vascular disease (hazard ratio, 2.02; 95% CI, 1.02–3.97), and prior cerebrovascular disease (hazard ratio, 2.04; 95% CI, 1.01–4.15). Major stroke was associated with 30-day (odds ratio, 7.43; 95% CI, 2.45–22.53) and late (hazard ratio, 1.75; 95% CI, 1.01–3.04) mortality. Conclusions—: In a large cohort of patients undergoing transcatheter aortic valve implantation, the rates of acute and subacute CVEs were 2.7% and 2.4%, respectively. While balloon postdilation and valve dislodgment/embolization were the predictors of acute CVEs, new-onset atrial fibrillation determined a higher risk for subacute events. Late events were determined mainly by a history of chronic atrial fibrillation and peripheral and cerebrovascular disease. The occurrence of major stroke was associated with increased early and late mortality. These results provide important insights for the implementation of preventive measures for CVEs after transcatheter aortic valve implantation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rivaroxaban versus warfarin in nonvalvular atrial fibrillation
Patel, M. R., Mahaffey, K. W., Garg, J., Pan, G., Singer, D. E., Hacke, W., Breithardt, G., Halperin, J. L., Hankey, G. J., Piccini, J. P., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1009638 · Cited by 9,430
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTranscatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citationRegistry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Gilard, M., Eltchaninoff, H., Iung, B., Donzeau-Gouge, P., Chevreul, K., Fajadet, J., Leprince, P., Leguerrier, A., Lievre, M., Prat, A., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1114705 · Cited by 1,228
Leon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M., Mehran, R., Miller, C., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq406 · Cited by 1,219
Self-citationTamburino, C., Capodanno, D., Ramondo, A., Petronio, A. S., Ettori, F., Santoro, G., Klugmann, S., Bedogni, F., Maisano, F., Marzocchi, A., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.946533 · Cited by 1,124
Rodés-Cabau, J., Webb, J. G., Cheung, A., Ye, J., Dumont, E., Feindel, C. M., Osten, M., Natarajan, M. K., Velianou, J. L., Martucci, G., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.014 · Cited by 974
Self-citationMoat, N. E., Ludman, P., de Belder, M. A., Bridgewater, B., Cunningham, A. D., Young, C. P., Thomas, M., Kovac, J., Spyt, T., MacCarthy, P. A., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.050 · Cited by 884
Thomas, M., Schymik, G., Walther, T., Himbert, D., Lefèvre, T., Treede, H., Eggebrecht, H., Rubino, P., Michev, I., Lange, R., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.907402 · Cited by 875
Standardized Endpoint Definitions for Transcatheter Aortic Valve Implantation Clinical Trials
Leon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M., Mehran, R., Miller, C., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.005 · Cited by 733
Self-citationGender Differences in Stroke Incidence and Poststroke Disability in the Framingham Heart Study
Petrea, R. E., Beiser, A. S., Seshadri, S., Kelly-Hayes, M., Kase, C. S., & Wolf, P. A. (2009) · Stroke · doi:10.1161/strokeaha.108.542894 · Cited by 672
Transcatheter Versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2012) · Survey of Anesthesiology · doi:10.1097/01.sa.0000410147.99581.d4 · Cited by 633
Self-citationTranscatheter aortic valve implantation: first results from a multi-centre real-world registry
Zahn, R., Gerckens, U., Grube, E., Linke, A., Sievert, H., Eggebrecht, H., Hambrecht, R., Sack, S., Hauptmann, K. E., Richardt, G., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq339 · Cited by 596
Registry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Gilard, M., Eltchaninoff, H., Iung, Donzeau-Gouge, P., Chevreul, K., Fajadet, J., Leprince, P., Leguerrier, A., Lievre, M., Prat, A., et al. (2013) · Survey of Anesthesiology · doi:10.1097/01.sa.0000426523.25196.4e · Cited by 454
Eggebrecht, H., Schmermund, A., Voigtländer, T., Kahlert, P., Erbel, R., & Mehta, R. H. (2012) · EuroIntervention · doi:10.4244/eijv8i1a20 · Cited by 406
Messika-Zeitoun, D., Aubry, M.-C., Detaint, D., Bielak, L. F., Peyser, P. A., Sheedy, P. F., Turner, S. T., Breen, J. F., Scott, C., Tajik, A. J., et al. (2004) · Circulation · doi:10.1161/01.cir.0000135469.82545.d0 · Cited by 386
Miller, D. C., Blackstone, E. H., Mack, M. J., Svensson, L. G., Kodali, S. K., Kapadia, S., Rajeswaran, J., Anderson, W. N., Moses, J. W., Tuzcu, E. M., et al. (2012) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2012.01.055 · Cited by 343
Self-citationCerebral Embolization During Transcatheter Aortic Valve Implantation: A Transcranial Doppler Study
Kahlert, P., Al-Rashid, F., Döttger, P., Mori, K., Plicht, B., Wendt, D., Bergmann, L., Kottenberg, E., Schlamann, M., Mummel, P., et al. (2012) · Circulation · doi:10.1161/circulationaha.112.092544 · Cited by 335
Transcatheter aortic valve implantation: current and future approaches
Rodés-Cabau, J. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2011.164 · Cited by 306
Self-citationAortic Atherosclerotic Disease and Stroke
Kronzon, I., & Tunick, P. A. (2006) · Circulation · doi:10.1161/circulationaha.105.593418 · Cited by 296
Stroke after cardiac surgery: short- and long-term outcomes
Salazar, J. D., Wityk, R. J., Grega, M. A., Borowicz, L. M., Doty, J. R., Petrofski, J. A., & Baumgartner, W. A. (2001) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(01)02929-0 · Cited by 260
Amat-Santos, I. J., Rodés-Cabau, J., Urena, M., DeLarochellière, R., Doyle, D., Bagur, R., Villeneuve, J., Côté, M., Nombela-Franco, L., Philippon, F., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.09.061 · Cited by 259
Self-citationAortic Valve Replacement in Octogenarians: Risk Factors for Early and Late Mortality
Melby, S. J., Zierer, A., Kaiser, S. P., Guthrie, T. J., Keune, J. D., Schuessler, R. B., Pasque, M. K., Lawton, J. S., Moazami, N., Moon, M. R., et al. (2007) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2006.09.068 · Cited by 224
Nombela-Franco, L., Rodés-Cabau, J., DeLarochellière, R., Larose, E., Doyle, D., Villeneuve, J., Bergeron, S., Bernier, M., Amat-Santos, I. J., Mok, M., et al. (2012) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2012.02.010 · Cited by 219
Self-citationAtrial fibrillation following cardiac surgery: clinical features and preventative strategies
Kaireviciute, D., Aidietis, A., & Lip, G. Y. H. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn609 · Cited by 173
A High-Risk Period for Cerebrovascular Events Exists After Transcatheter Aortic Valve Implantation
Tay, E. L. W., Gurvitch, R., Wijesinghe, N., Nielispach, F., Wood, D., Cheung, A., Ye, J., Lichtenstein, S. V., Carere, R., Thompson, C., et al. (2011) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2011.08.012 · Cited by 171
Self-citationFrequency and Causes of Stroke During or After Transcatheter Aortic Valve Implantation
Nuis, R.-J. M., Mieghem, N. M. V., Schultz, C. J., Moelker, A. D., van der Boon, R. M., van Geuns, R., van der Lugt, A., Serruys, P. W. J. C., Rodés‐Cabau, J., van Domburg, R. T., et al. (2012) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2012.01.389 · Cited by 159
Self-citationTakagi, K., Latib, A., Al-Lamee, R. K., Mussardo, M., Montorfano, M., Maisano, F., Godino, C., Chieffo, A., Alfieri, O., & Colombo, A. (2011) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.23003 · Cited by 153
Naber, C. K., Ghanem, A., Abizaid, A., Wolf, A., Sinning, J., Werner, N., Nickenig, G., Schmitz, T., & Grube, E. (2012) · EuroIntervention · doi:10.4244/eijv8i1a8 · Cited by 143
An Embolic Deflection Device for Aortic Valve Interventions
Nietlispach, F., Wijesinghe, N., Gurvitch, R., Tay, E. L. W., Carpenter, J. P., Burns, C. A., Wood, D. A., & Webb, J. G. (2010) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2010.05.022 · Cited by 136
Self-citationTranscranial Doppler-detected cerebral embolic load during transcatheter aortic valve implantation
Erdoes, G., Basciani, R., Huber, C. H., Stortecky, S., Wenaweser, P., Windecker, S., Carrel, T., & Eberle, B. (2011) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezr068 · Cited by 121
Stortecky, S., Windecker, S., Pilgrim, T., Heg, D., Buellesfeld, L., Khattab, A. A., Huber, C. H., Gloekler, S., Nietlispach, F., Mattle, H. P., et al. (2012) · EuroIntervention · doi:10.4244/eijv8i1a11 · Cited by 118
Kempfert, J., Rastan, A. J., Holzhey, D. M., Linke, A. H.-P., Schuler, G. C., Linden, A. V., Blumenstein, J., Mohr, F. W., & Walther, T. (2011) · Circulation · doi:10.1161/circulationaha.110.013425 · Cited by 98
Schultz, C. J., Rossi, A., Mieghem, N. M. V., van der Boon, R., Papadopoulou, S., van Domburg, R., Moelker, A. D., Mollet, N. R., Krestin, G. P., van Geuns, R., et al. (2011) · EuroIntervention · doi:10.4244/eijv7i5a92 · Cited by 93
Onsea, K., Agostoni, P., Samim, M., Voskuil, M., Kluin, J., Budde, R. P. J., Hendrikse, J., Ramjankhan, F. Z., van Klarenbosch, J., Doesburg, P., et al. (2012) · EuroIntervention · doi:10.4244/eijv8i1a9 · Cited by 76
Cerebral Embolic Exposure During Transfemoral and Transapical Transcatheter Aortic Valve Replacement
Szeto, W. Y., Augoustides, J. G., Desai, N. D., Moeller, P. J., McGarvey, M. L., Walsh, E., Bannan, A. T., Herrmann, H. C., & Bavaria, J. E. (2011) · Journal of Cardiac Surgery · doi:10.1111/j.1540-8191.2011.01265.x · Cited by 68
Transcatheter aortic valve implantation and cerebrovascular events: the current state of the art
Hynes, B. G., & Rodés‐Cabau, J. (2012) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2012.06477.x · Cited by 57
Self-citation(2010) · Circulation · doi:10.1161/cir.0b013e3181f80fbb · Cited by 2
Cited by
2017 EACTS Guidelines on perioperative medication in adult cardiac surgery
Sousa-Uva*, M., Head, S. J., Milojevic, M., Collet, J.-P., Landoni, G., Castella, M., Dunning, J., Gudbjartsson, T., Linker, N. J., Sandoval, E., et al. (2018) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezx314 · Cited by 393
Rodés-Cabau, J., Masson, J.-B., Welsh, R. C., Garcia del Blanco, B., Pelletier, M., Webb, J. G., Al-Qoofi, F., Généreux, P., Maluenda, G., Thoenes, M., et al. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.04.014 · Cited by 331
Self-citationRodés-Cabau, J., Pibarot, P., Suri, R. M., Kodali, S., Thourani, V. H., Szeto, W. Y., Svensson, L. G., Dumont, E., Xu, K., Hahn, R. T., et al. (2014) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.114.001681 · Cited by 130
Self-citation
Metadata
- Authors
- Nombela-Franco, L., Webb, J. G., de Jaegere, P. P., Toggweiler, S., Nuis, R.-J., Dager, A. E., Amat-Santos, I. J., Cheung, A., Ye, J., Binder, R. K., van der Boon, R. M., Van Mieghem, N., Benitez, L. M., Pérez, S., Lopez, J., San Roman, J. A., Doyle, D., DeLarochellière, R., Urena, M., Leipsic, J., Dumont, E., & Rodés-Cabau, J.
- Venue
- Circulation
- Published
- 2012-12-18
- Volume
- 126
- Issue
- 25
- Pages
- 3041-3053
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2097310220
- Cited by
- 422
- References
- 38
- FWCI
- 17.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.