Influence of diabetes mellitus on inappropriate and appropriate implantable cardioverter-defibrillator therapy and mortality in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT) Trial

Open access
Ruwald, Martin H., Zareba, Wojciech, Jons, Christian, Zhang, Claire, Ruwald, Anne-Christine H., Olshansky, Brian, McNitt, Scott, Bloch Thomsen, Poul Erik +4 more·2013·Circulation

Abstract

Background—: The relationship between diabetes mellitus and risk of inappropriate or appropriate therapy in patients receiving an implantable cardioverter-defibrillator (ICD) and resynchronization therapy has not been investigated thoroughly. The effect of innovative ICD programming on therapy delivery in these patients is unknown. Methods and Results—: The Multicenter Automatic Defibrillator Implantation Trial–Reduce Inappropriate Therapy (MADIT-RIT) randomized patients with a primary prophylactic ICD indication to 3 different types of ICD programming: conventional programming with a ventricular tachycardia zone of 170 to 199 bpm (arm A), high-rate cutoff with a ventricular tachycardia zone ≥200 bpm (arm B), or 60-second-delayed therapy (arm C). The end points of inappropriate therapy, appropriate therapy, and death were assessed among 485 patients with and 998 without diabetes mellitus. Innovative ICD programming reduced the risk of inappropriate therapy regardless of diabetes mellitus, although a trend toward a more pronounced effect of high-rate cutoff programming was seen in patients without diabetes mellitus ( P for interaction=0.06). Diabetes mellitus was associated with a decreased risk of inappropriate therapy (hazard ratio, 0.54; 95% confidence interval, 0.36–0.80; P =0.002) and increased risk of appropriate therapy (hazard ratio, 1.58; 95% confidence interval, 1.17–2.14; P =0.003). In diabetic patients, there was significantly increased risk of death in those who had inappropriate therapy (hazard ratio, 4.17; 95% confidence interval, 1.52–11.40; P =0.005) and appropriate therapy (hazard ratio, 2.49; 95% confidence interval, 1.06–5.87; P =0.037) compared with those who did not. Conclusions—: Innovative high-rate cutoff or delayed ICD programming was associated with a reduction in inappropriate therapy in patients with and without diabetes mellitus. Diabetes mellitus was associated with lower risk of inappropriate therapy but higher risk of appropriate therapy. Appropriate and inappropriate ICD therapy was associated with increased mortality in diabetic patients. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT00947310.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.113.002472

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Observational studies have reported significant corrected QT interval prolongation possibly associated with microvascular complications, atypical patterns of microvolt T-wave alternans, altered heart rate variability, or heart rate turbulence in patients with diabetes.

    “Observational studies have reported significant corrected QT (QTc) interval prolongation possibly associated with microvascular complications, atypical patterns of microvolt T-wave alternans, altered heart rate variability, or heart rate turbulence in patients with diabetes, but none of these tests should routinely be used to stratify the risk of ventricular arrhythmias or SCD in clinical practice”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ruwald, M. H., Zareba, W., Jons, C., Zhang, C., Ruwald, A.-C. H., Olshansky, B., McNitt, S., Bloch Thomsen, P. E., Shoda, M., Merkely, B., Moss, A. J., & Kutyifa, V.
Affiliations
  • Semmelweis University (HU)
  • From the Heart Research Follow-Up Program, University of Rochester Medical Center, Rochester, NY (M.H.R., W.Z., C.Z., A.-C.H.R., S.M., A.J.M., V.K.); Department of Cardiology, Gentofte Hospital, Hellerup, Denmark (M.H.R., C.J., A.-C.H.R.); Department of Medicine, University of Iowa Health Care, Iowa City (B.O.); Faculty of Medicine, University of Aalborg, Aalborg, Denmark (P.E.B.T.); Department of Cardiology, Tokyo Women’s Medical University, Tokyo, Japan (M.S.); and Heart Center, Semmelweis...
Venue
Circulation
Published
2013-08-13
Volume
128
Issue
7
Pages
694-701
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2122209221
Cited by
30
References
40
Citations by year
2026: 1 · 2025: 2 · 2024: 2 · 2023: 3 · 2022: 3 · 2021: 1 · 2020: 2 · 2019: 2 · 2018: 1 · 2017: 2 · 2016: 3 · 2015: 4 · 2014: 4
FWCI
2.49
Type
journal article
Language
en
Open access
Locations
  • Circulation (publishedVersion)
  • PubMed (publishedVersion)
  • VBN Forskningsportal (Aalborg Universitet) (submittedVersion)
Funders
  • University of Rochester
  • Boston Scientific Corporation
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
Keywords
diabetes mellitus, implantable cardioverter-defibrillator, inappropriate ICD therapy, appropriate ICD therapy, ICD programming, ventricular tachycardia detection, mortality, prophylactic ICD, cardiac resynchronization therapy, ventricular arrhythmias
MeSH terms
Aged, Algorithms, Arrhythmias, Cardiac, Electric Countershock, Equipment Failure, Female, Follow-Up Studies, Humans, Male, Middle Aged, Models, Cardiovascular, Risk, Proportional Hazards Models, Single-Blind Method, Defibrillators, Implantable, Tachycardia, Ventricular, Unnecessary Procedures, Diabetes Complications, Kaplan-Meier Estimate, Cardiac Resynchronization Therapy, Cardiac Resynchronization Therapy Devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review