Temporal Relationship Between Subclinical Atrial Fibrillation and Embolic Events
Open accessAbstract
BACKGROUND: Among patients with implantable pacemakers and defibrillators, subclinical atrial fibrillation (SCAF) is associated with an increased risk of stroke; however, there is limited understanding of their temporal relationship. METHODS AND RESULTS: The Asymptomatic Atrial Fibrillation and Stroke Evaluation in Pacemaker Patients and the Atrial Fibrillation Reduction Atrial Pacing Trial (ASSERT) enrolled 2580 pacemaker and defibrillator patients aged ≥65 years with a history of hypertension but without a history of atrial fibrillation. Pacemakers and implantable cardioverter-defibrillators precisely logged the time and duration of all episodes of SCAF and recorded electrograms that were adjudicated by experts. We examined the temporal relationship between SCAF >6 minutes in duration and stroke or systemic embolism. Of 51 patients who experienced stroke or systemic embolism during follow-up, 26 (51%) had SCAF. In 18 patients (35%), SCAF was detected before stroke or systemic embolism. However, only 4 patients (8%) had SCAF detected within 30 days before stroke or systemic embolism, and only 1 of these 4 patients was experiencing SCAF at the time of the stroke. In the 14 patients with SCAF detected >30 days before stroke or systemic embolism, the most recent episode occurred at a median interval of 339 days (25th to 75th percentile, 211-619) earlier. Eight patients (16%) had SCAF detected only after their stroke, despite continuous monitoring for a median duration of 228 days (25th to 75th percentile, 202-719) before their event. CONCLUSIONS: Although SCAF is associated with an increased risk of stroke and embolism, very few patients had SCAF in the month before their event. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00256152.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The detection of supraventricular tachycardia (SVT) may be important as well as it is associated with the development of AF and an increased risk of stroke even in patients without AF (4–6).”
From Diagnostic Yield of Extended Cardiac Patch Monitoring in Patients with Stroke or TIA (2015) · cites this paper as [5]
Experimental — accuracy not yet measuredIn the citing paper
“Strokes often occur without AHRE detected within 30 days before the event.143-147”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [143]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atrial fibrillation as an independent risk factor for stroke: the Framingham study
Wolf, P. A., Abbott, R. D., & Kannel, W. B. (1991) · Stroke · doi:10.1161/01.str.22.8.983 · Cited by 7,388
Lip, G. Y. H., Nieuwlaat, R., Pisters, R., Lane, D. A., & Crijns, H. J. G. M. (2010) · Chest · doi:10.1378/chest.09-1584 · Cited by 6,879
Kearon (2012) · doi:10.1378/chest.11-2301 · Cited by 6,119
Subclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100
Kannel, W. B., Wolf, P. A., Benjamin, E. J., & Levy, D. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00583-9 · Cited by 2,033
Mechanisms of thrombogenesis in atrial fibrillation: Virchow's triad revisited
Watson, T., Shantsila, E., & Lip, G. Y. H. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60040-4 · Cited by 1,124
Antithrombotic Therapy for Atrial Fibrillation
You, J. J., Singer, D. E., Howard, P. A., Lane, D. A., Eckman, M. H., Fang, M. C., Hylek, E. M., Schulman, S., Go, A. S., Hughes, M., et al. (2012) · CHEST Journal · doi:10.1378/chest.11-2304 · Cited by 933
Glotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879 · cited 1×
“190 Systemic embolism 4 (16) 1 (4) 5 (10) 0.”
Inflammation in Atrial Fibrillation
Guo, Y., Lip, G. Y. H., & Apostolakis, S. Z. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.04.063 · Cited by 868
Glotzer, T. V., Hellkamp, A. S., Zimmerman, J., Sweeney, M. O., Yee, R., Marinchak, R., Cook, J., Paraschos, A., Love, J., Radoslovich, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000057981.70380.45 · Cited by 750
Manning, W. J., Silverman, D. I., Katz, S. E., Riley, M. F., Come, P. C., Doherty, R. M., Munson, J. T., & Douglas, P. S. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90652-1 · Cited by 532
Long-term risk of recurrent atrial fibrillation as documented by an implantable monitoring device
Israel, C. W., Grönefeld, G., Ehrlich, J. R., Li, Y., & Hohnloser, S. H. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.027 · Cited by 478
Left atrial spontaneous echo contrast: A clinical and echocardiographic analysis
Black, I. W., Hopkins, A. P., Lee, L. C. L., & Walsh, W. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90592-w · Cited by 432
Hindricks, G., Pokushalov, E., Urban, L., Taborsky, M., Kuck, K.-H., Lebedev, D., Rieger, G., & Pürerfellner, H. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.877852 · Cited by 422
Flaker, G. C., Belew, K., Beckman, K., Vidaillet, H., Kron, J., Safford, R., Mickel, M., & Barrell, P. (2005) · American Heart Journal · doi:10.1016/j.ahj.2004.06.032 · Cited by 341 · cited 2×
“2 CHA2DS2-VASc ‡ Median (P25-P75) 5 (3-5) 5 (4-5) 5 (4-5) 0.”
Liao, J., Khalid, Z., Scallan, C., Morillo, C., & O’Donnell, M. (2007) · Stroke · doi:10.1161/strokeaha.106.478685 · Cited by 331
Self-citationDaoud, E. G., Glotzer, T. V., Wyse, D. G., Ezekowitz, M. D., Hilker, C., Koehler, J., & Ziegler, P. D. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.04.022 · Cited by 326
Atrial fibrillation detected by mobile cardiac outpatient telemetry in cryptogenic TIA or stroke
Tayal, A. H., Tian, M., Kelly, K., Jones, S. C., Wright, D. G., Singh, D., Jarouse, J., Brillman, J. S., Murali, S., & Gupta, R. (2008) · Neurology · doi:10.1212/01.wnl.0000325059.86313.31 · Cited by 316
Weigner, M. J., Caulfield, T. A., Danias, P. G., Silverman, D. I., & Manning, W. J. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-126-8-199704150-00005 · Cited by 238
Healey, J. S., Hart, R. G., Pogue, J. M., Pfeffer, M. A., Hohnloser, S. H., Caterina, R. D., Flaker, G., Yusuf, S., & Connolly, S. J. (2008) · Stroke · doi:10.1161/strokeaha.107.500199 · Cited by 225
Oldgren, J., Alings, M., Darius, H., Diener, H.-C., Eikelboom, J., Ezekowitz, M. D., Kamensky, G., Reilly, P. A., Yang, S., Yusuf, S., et al. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-10-201111150-00004 · Cited by 196
Ziegler, P. D., Glotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Koehler, J. L., & Hilker, C. E. (2010) · Stroke · doi:10.1161/strokeaha.109.571455 · Cited by 173
Cryptogenic Stroke and underlying Atrial Fibrillation (CRYSTAL AF): Design and rationale
Sinha, A. M., Diener, H., Morillo, C. A., Sanna, T., Bernstein, R. A., Lazzaro, V. D., PASSMAN, R. S., Beckers, F., & Brachmann, J. (2010) · American Heart Journal · doi:10.1016/j.ahj.2010.03.032 · Cited by 134
Hohnloser, S. H., Capucci, A., Fain, E. S., Gold, M. R., Gelder, I. C. V., Healey, J. S., Israel, C. W., Lau, C., Morillo, C. A., & Connolly, S. J. (2006) · American Heart Journal · doi:10.1016/j.ahj.2006.02.016 · Cited by 129
Ip, J. E., Waldo, A. L., Lip, G. Y. H., Rothwell, P. M., Martin, D. T., BERSOHN, M. M., Choucair, W. K., Akar, J. G., Wathen, M. S., Rohani, P., et al. (2009) · American Heart Journal · doi:10.1016/j.ahj.2009.07.002 · Cited by 106
Healey, J. S., Martin, J. L., Duncan, A., Connolly, S. J., Ha, A. H., Morillo, C. A., Nair, G. M., Eikelboom, J. W., Divakaramenon, S., & Dokainish, H. (2012) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2012.08.019 · Cited by 87
Regional left atrial stasis during fibrillation and flutter determinants and relation to stroke
Shively, B. K., Gelgand, E. A., & Crawford, M. H. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(96)00049-6 · Cited by 85
Inoue, H., Nozawa, T., Okumura, K., Jong-Dae, L., Shimizu, A., & Yano, K. (2004) · CHEST Journal · doi:10.1378/chest.126.3.687 · Cited by 77
Khan, I. A. (2002) · American Heart Journal · doi:10.1067/mhj.2002.123113 · Cited by 66
The endothelium and atrial fibrillation
Freestone, B., & Lip, G. Y. H. (2008) · Hämostaseologie · doi:10.1055/s-0037-1617102 · Cited by 40
How much atrial fibrillation is too much atrial fibrillation?
Lamas, G. (2012) · New England Journal of Medicine · doi:10.1056/nejme1111948 · Cited by 36
Research works printed but not linked: 1
- Anderson K, Benzauquen BS. Do patients with pacemaker-detected atrial fibrillation receive appropriate anticoagulation? Europace. 2011;13:519.
Cited by
Sorted by citations
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström‐Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 10,550
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P. F., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castellà, M., Diener, H., Heidbüchel, H., Hendriks, J., et al. (2016) · EP Europace · doi:10.1093/europace/euw295 · Cited by 6,438
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A. M., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2023) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 3,072
Stroke risk factors, genetics, and prevention
Boehme, A. K., Esenwa, C., & Elkind, M. S. V. (2017) · Circulation Research · doi:10.1161/circresaha.116.308398 · Cited by 1,952
Metadata
- Authors
- Brambatti, M., Connolly, S. J., Gold, M. R., Morillo, C. A., Capucci, A., Muto, C., Lau, C. P., Van Gelder, I. C., Hohnloser, S. H., Carlson, M., Fain, E., Nakamya, J., Mairesse, G. H., Halytska, M., Deng, W. Q., Israel, C. W., & Healey, J. S.
- Affiliations
- Goethe University Frankfurt (DE)
- From the Population Health Research Institute, McMaster University, Hamilton, Ontario, Canada (M.B., S.J.C., C.A.M., J.N., M.H., W.Q.D., J.S.H.); Clinica di Cardiologia, Università Politecnica delle Marche, Ancona, Italy (M.B., A.C.); Medical University of South Carolina, Charleston (M.R.G.); Cardiology Department, Loreto Mare, Napoli, Italy (C.M.); Queen Mary Hospital, Department of Medicine, University of Hong Kong, Hong Kong, China (C.P.L.); University of Groningen, University Medical Center...
- ORCID
- Venue
- Circulation
- Published
- 2014-05-27
- Volume
- 129
- Issue
- 21
- Pages
- 2094-2099
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2024497977
- Cited by
- 676
- References
- 31
- Citations by year
- 2026: 21 · 2025: 35 · 2024: 52 · 2023: 66 · 2022: 62 · 2021: 67 · 2020: 55 · 2019: 63 · 2018: 57 · 2017: 66 · 2016: 58 · 2015: 57 · 2014: 15
- FWCI
- 44.81
- Type
- journal article
- Language
- en
- Open access
- Licence
- other-oa
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Università Politecnica delle Marche (Università Politecnica delle Marche) (submittedVersion)
- University of Groningen research database (University of Groningen / Centre for Information Technology) (submittedVersion)
- INFM-OAR (INFN Catania) (submittedVersion, other-oa)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Cardiovascular and Diving-Related Complications
- Keywords
- subclinical atrial fibrillation, stroke, systemic embolism, implantable cardioverter-defibrillator, cardiac pacemaker, temporal relations, asymptomatic atrial fibrillation, hypertension
- MeSH terms
- Aged, Aged, 80 and over, Atrial Fibrillation, Embolism, Female, Follow-Up Studies, Humans, Male, Pacemaker, Artificial, Prospective Studies, Risk Factors, Time Factors, Stroke
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review