Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 317

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Diagnostic Accuracy of the Aortic Dissection Detection Risk Score Plus D-Dimer for Acute Aortic Syndromes: The ADvISED Prospective Multicenter Study

Open access
Nazerian, Peiman, Mueller, Christian, Soeiro, Alexandre de Matos, Leidel, Bernd A., Salvadeo, Sibilla Anna Teresa, Giachino, Francesca, Vanni, Simone, Grimm, Karin, Oliveira, Múcio Tavares, Pivetta, Emanuele, Lupia, Enrico, Grifoni, Stefano, Morello, Fulvio, Capretti, Elisa, Castelli, Matteo, Gualtieri, Simona, Trausi, Federica, Battista, Stefania, Bima, Paolo, Carbone, Federica, Tizzani, Maria, Veglio, Maria G., Badertscher, Patrick, Boeddinghaus, Jasper, Nestelberger, Thomas, Twerenbold, Raphael · 2018 · Circulation

Abstract

Background: Acute aortic syndromes (AASs) are rare and severe cardiovascular emergencies with unspecific symptoms. For AASs, both misdiagnosis and overtesting are key concerns, and standardized diagnostic strategies may help physicians to balance these risks. D-dimer (DD) is highly sensitive for AAS but is inadequate as a stand-alone test. Integration of pretest probability assessment with DD testing is feasible, but the safety and efficiency of such a diagnostic strategy are currently unknown. Methods: In a multicenter prospective observational study involving 6 hospitals in 4 countries from 2014 to 2016, consecutive outpatients were eligible if they had ≥1 of the following: chest/abdominal/back pain, syncope, perfusion deficit, and if AAS was in the differential diagnosis. The tool for pretest probability assessment was the aortic dissection detection risk score (ADD-RS, 0–3) per current guidelines. DD was considered negative (DD−) if <500 ng/mL. Final case adjudication was based on conclusive diagnostic imaging, autopsy, surgery, or 14-day follow-up. Outcomes were the failure rate and efficiency of a diagnostic strategy for ruling out AAS in patients with ADD-RS=0/DD− or ADD-RS ≤1/DD−. Results: A total of 1850 patients were analyzed. Of these, 438 patients (24%) had ADD-RS=0, 1071 patients (58%) had ADD-RS=1, and 341 patients (18%) had ADD-RS >1. Two hundred forty-one patients (13%) had AAS: 125 had type A aortic dissection, 53 had type B aortic dissection, 35 had intramural aortic hematoma, 18 had aortic rupture, and 10 had penetrating aortic ulcer. A positive DD test result had an overall sensitivity of 96.7% (95% confidence interval [CI], 93.6–98.6) and a specificity of 64% (95% CI, 61.6–66.4) for the diagnosis of AAS; 8 patients with AAS had DD−. In 294 patients with ADD-RS=0/DD−, 1 case of AAS was observed. This yielded a failure rate of 0.3% (95% CI, 0.1–1.9) and an efficiency of 15.9% (95% CI, 14.3–17.6) for the ADD-RS=0/DD− strategy. In 924 patients with ADD-RS ≤1/DD−, 3 cases of AAS were observed. This yielded a failure rate of 0.3% (95% CI, 0.1–1) and an efficiency of 49.9% (95% CI, 47.7–52.2) for the ADD-RS ≤1/DD− strategy. Conclusions: Integration of ADD-RS (either ADD-RS=0 or ADD-RS ≤1) with DD may be considered to standardize diagnostic rule out of AAS. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02086136.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.117.029457

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 317

Metadata

Authors
Nazerian, P., Mueller, C., Soeiro, A. D. M., Leidel, B. A., Salvadeo, S. A. T., Giachino, F., Vanni, S., Grimm, K., Oliveira, M. T., Pivetta, E., Lupia, E., Grifoni, S., Morello, F., Capretti, E., Castelli, M., Gualtieri, S., Trausi, F., Battista, S., Bima, P., Carbone, F., Tizzani, M., Veglio, M. G., Badertscher, P., Boeddinghaus, J., Nestelberger, T., & Twerenbold, R.
Venue
Circulation
Published
2018-01-16
Volume
137
Issue
3
Pages
250-258
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2762211323
Cited by
317
References
19
FWCI
16.40
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic Accuracy of the Aortic Dissection Detection Risk Score Plus D-Dimer for Acute Aortic Syndromes: The ADvISED Prospective Multicenter Study. https://app.cochat.ai/papers/10.1161/circulationaha.117.029457
The paper
Nazerian, P., Mueller, C., Soeiro, A. D. M., Leidel, B. A., Salvadeo, S. A. T., Giachino, F., Vanni, S., Grimm, K., Oliveira, M. T., Pivetta, E., Lupia, E., Grifoni, S., Morello, F., Capretti, E., Castelli, M., Gualtieri, S., Trausi, F., Battista, S., Bima, P., . . . Twerenbold, R. (2018). Diagnostic Accuracy of the Aortic Dissection Detection Risk Score Plus D-Dimer for Acute Aortic Syndromes: The ADvISED Prospective Multicenter Study. Circulation. https://doi.org/10.1161/circulationaha.117.029457

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.