Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 421

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

The Evolving Landscape of Impella Use in the United States Among Patients Undergoing Percutaneous Coronary Intervention With Mechanical Circulatory Support

Open access
Amin, Amit P., Spertus, John A., Curtis, Jeptha P., Desai, Nihar, Masoudi, Frederick A., Bach, Richard G., McNeely, Christian, Al-Badarin, Firas, House, John A., Kulkarni, Hemant, Rao, Sunil V.·2020·Circulation

Abstract

Background: Impella was approved for mechanical circulatory support (MCS) in 2008, but large-scale, real-world data on its use are lacking. Our objective was to describe trends and variations in Impella use, clinical outcomes, and costs across US hospitals in patients undergoing percutaneous coronary intervention (PCI) treated with MCS (Impella or intra-aortic balloon pump). Methods: From the Premier Healthcare Database, we analyzed 48 306 patients undergoing PCI with MCS at 432 hospitals between January 2004 and December 2016. Association analyses were performed at 3 levels: time period, hospital, and patient. Hierarchical models with propensity adjustment were used for association analyses. We examined trends and variations in the proportion of Impella use, and associated clinical outcomes (in-hospital mortality, bleeding requiring transfusion, acute kidney injury, stroke, length of stay, and hospital costs). Results: Among patients undergoing PCI treated with MCS, 4782 (9.9%) received Impella; its use increased over time, reaching 31.9% of MCS in 2016. There was wide variation in Impella use across hospitals (>5-fold variation). Specifically, among patients receiving Impella, there was a wide variation in outcomes of bleeding (>2.5-fold variation), and death, acute kidney injury, and stroke (all ≈1.5-fold variation). Adverse outcomes and costs were higher in the Impella era (years 2008–2016) versus the pre-Impella era (years 2004–2007). Hospitals with higher Impella use had higher rates of adverse outcomes and costs. After adjustment for the propensity score, and accounting for clustering of patients by hospitals, Impella use was associated with death: odds ratio, 1.24 (95% CI, 1.13–1.36); bleeding: odds ratio, 1.10 (95% CI, 1.00–1.21); and stroke: odds ratio, 1.34 (95% CI, 1.18–1.53), although a similar, nonsignificant result was observed for acute kidney injury: odds ratio, 1.08 (95% CI, 1.00–1.17). Conclusions: Impella use is rapidly increasing among patients undergoing PCI treated with MCS, with marked variability in its use and associated outcomes. Although unmeasured confounding cannot be ruled out, when analyzed by time periods, or at the hospital level or the patient level, Impella use was associated with higher rates of adverse events and costs. More data are needed to define the appropriate role of MCS in patients undergoing PCI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.119.044007

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 421

Metadata

Authors
Amin, A. P., Spertus, J. A., Curtis, J. P., Desai, N., Masoudi, F. A., Bach, R. G., McNeely, C., Al-Badarin, F., House, J. A., Kulkarni, H., & Rao, S. V.
Venue
Circulation
Published
2020-01-28
Volume
141
Issue
4
Pages
273-284
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2984895516
Cited by
421
References
24
FWCI
17.33
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.