The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
ECG-Based Deep Learning and Clinical Risk Factors to Predict Atrial Fibrillation
Open accessAbstract
Background: Artificial intelligence (AI)–enabled analysis of 12-lead ECGs may facilitate efficient estimation of incident atrial fibrillation (AF) risk. However, it remains unclear whether AI provides meaningful and generalizable improvement in predictive accuracy beyond clinical risk factors for AF. Methods: We trained a convolutional neural network (ECG-AI) to infer 5-year incident AF risk using 12-lead ECGs in patients receiving longitudinal primary care at Massachusetts General Hospital (MGH). We then fit 3 Cox proportional hazards models, composed of ECG-AI 5-year AF probability, CHARGE-AF clinical risk score (Cohorts for Heart and Aging in Genomic Epidemiology–Atrial Fibrillation), and terms for both ECG-AI and CHARGE-AF (CH-AI), respectively. We assessed model performance by calculating discrimination (area under the receiver operating characteristic curve) and calibration in an internal test set and 2 external test sets (Brigham and Women’s Hospital [BWH] and UK Biobank). Models were recalibrated to estimate 2-year AF risk in the UK Biobank given limited available follow-up. We used saliency mapping to identify ECG features most influential on ECG-AI risk predictions and assessed correlation between ECG-AI and CHARGE-AF linear predictors. Results: The training set comprised 45 770 individuals (age 55±17 years, 53% women, 2171 AF events) and the test sets comprised 83 162 individuals (age 59±13 years, 56% women, 2424 AF events). Area under the receiver operating characteristic curve was comparable using CHARGE-AF (MGH, 0.802 [95% CI, 0.767–0.836]; BWH, 0.752 [95% CI, 0.741–0.763]; UK Biobank, 0.732 [95% CI, 0.704–0.759]) and ECG-AI (MGH, 0.823 [95% CI, 0.790–0.856]; BWH, 0.747 [95% CI, 0.736–0.759]; UK Biobank, 0.705 [95% CI, 0.673–0.737]). Area under the receiver operating characteristic curve was highest using CH-AI (MGH, 0.838 [95% CI, 0.807 to 0.869]; BWH, 0.777 [95% CI, 0.766 to 0.788]; UK Biobank, 0.746 [95% CI, 0.716 to 0.776]). Calibration error was low using ECG-AI (MGH, 0.0212; BWH, 0.0129; UK Biobank, 0.0035) and CH-AI (MGH, 0.012; BWH, 0.0108; UK Biobank, 0.0001). In saliency analyses, the ECG P-wave had the greatest influence on AI model predictions. ECG-AI and CHARGE-AF linear predictors were correlated (Pearson r : MGH, 0.61; BWH, 0.66; UK Biobank, 0.41). Conclusions: AI-based analysis of 12-lead ECGs has similar predictive usefulness to a clinical risk factor model for incident AF and the approaches are complementary. ECG-AI may enable efficient quantification of future AF risk.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
R: A Language and Environment for Statistical Computing
R Core Team (2025) · doi:10.32614/r.manuals · Cited by 352,181
(2014) · Cited by 33,419
Lip, G. Y. H., Nieuwlaat, R., Pisters, R., Lane, D. A., & Crijns, H. J. G. M. (2010) · Chest · doi:10.1378/chest.09-1584 · Cited by 6,879
Practical Bayesian Optimization of Machine Learning Algorithms
Snoek, J., Larochelle, H., & Adams, R. P. (2012) · arXiv · doi:10.48550/arxiv.1206.2944 · Cited by 6,691
Ruff, C. T., Giugliano, R. P., Braunwald, E., Hoffman, E. B., Deenadayalu, N., Ezekowitz, M. D., Camm, A. J., Weitz, J. I., Lewis, B. S., Parkhomenko, A., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(13)62343-0 · Cited by 5,051
Extensions of net reclassification improvement calculations to measure usefulness of new biomarkers
Pencina, M. J., D'Agostino, R. B., & Steyerberg, E. W. (2011) · Statistics in Medicine · doi:10.1002/sim.4085 · Cited by 2,453
D'Agostino, R. B., Grundy, S., Sullivan, L. M., Wilson, P., & for the CHD Risk Prediction Group (2001) · JAMA · doi:10.1001/jama.286.2.180 · Cited by 2,108
Stroke Prevention in Atrial Fibrillation Study. Final results.
(1991) · Circulation · doi:10.1161/01.cir.84.2.527 · Cited by 1,696
Attia, Z. I., Noseworthy, P. A., Lopez-Jimenez, F., Asirvatham, S. J., Deshmukh, A. J., Gersh, B. J., Carter, R. E., Yao, X., Rabinstein, A. A., Erickson, B. J., et al. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31721-0 · Cited by 1,613
Uno, H., Cai, T., Pencina, M. J., D'Agostino, R. B., & Wei, L. J. (2011) · Statistics in Medicine · doi:10.1002/sim.4154 · Cited by 1,535
Cited by
Armoundas, A. A., Narayan, S. M., Arnett, D. K., Spector-Bagdady, K., Bennett, D. A., Celi, L. A., Friedman, P. A., Gollob, M. H., Hall, J. L., Kwitek, A. E., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001201 · Cited by 347
Pediatric ECG-Based Deep Learning to Predict Left Ventricular Dysfunction and Remodeling
Mayourian, J., La Cava, W. G., Vaid, A., Nadkarni, G. N., Ghelani, S. J., Mannix, R., Geva, T., Dionne, A., Alexander, M. E., Duong, S. Q., et al. (2024) · Circulation · doi:10.1161/circulationaha.123.067750 · Cited by 59
Roadmap for alleviating the manifestations of ageing in the cardiovascular system
Liberale, L., Tual-Chalot, S., Sedej, S., Ministrini, S., Georgiopoulos, G., Grunewald, M., Bäck, M., Bochaton-Piallat, M.-L., Boon, R. A., Ramos, G. C., et al. (2025) · Nature Reviews Cardiology · doi:10.1038/s41569-025-01130-5 · Cited by 59
Muse, E. D., & Topol, E. J. (2024) · Cell Metabolism · doi:10.1016/j.cmet.2024.02.002 · Cited by 50
Siontis, K. C., Suárez, A. B., Sehrawat, O., Ackerman, M. J., Attia, Z. I., Friedman, P. A., Noseworthy, P. A., & Maanja, M. (2023) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2023.07.002 · Cited by 38
Metadata
- Authors
- Khurshid, S., Friedman, S., Reeder, C., Di Achille, P., Diamant, N., Singh, P., Harrington, L. X., Wang, X., Al-Alusi, M. A., Sarma, G., Foulkes, A. S., Ellinor, P. T., Anderson, C. D., Ho, J. E., Philippakis, A. A., Batra, P., & Lubitz, S. A.
- Venue
- Circulation
- Published
- 2022-01-11
- Volume
- 145
- Issue
- 2
- Pages
- 122-133
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W3212883348
- Cited by
- 322
- References
- 48
- FWCI
- 27.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ECG-Based Deep Learning and Clinical Risk Factors to Predict Atrial Fibrillation. https://app.cochat.ai/papers/10.1161/circulationaha.121.057480
- The paper
- Khurshid, S., Friedman, S., Reeder, C., Di Achille, P., Diamant, N., Singh, P., Harrington, L. X., Wang, X., Al-Alusi, M. A., Sarma, G., Foulkes, A. S., Ellinor, P. T., Anderson, C. D., Ho, J. E., Philippakis, A. A., Batra, P., & Lubitz, S. A. (2022). ECG-Based Deep Learning and Clinical Risk Factors to Predict Atrial Fibrillation. Circulation. https://doi.org/10.1161/circulationaha.121.057480
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.