CoChat

Overexpression of the Serine Elastase Inhibitor Elafin Protects Transgenic Mice From Hypoxic Pulmonary Hypertension

Open access
Zaidi, Syed H.E., You, Xiao-Mang, Ciura, Sorana, Husain, Mansoor, Rabinovitch, Marlene · 2002 · Circulation
Cited by 186

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Background — Increased serine elastase activity has been implicated in the vascular remodeling associated with chronic hypoxia-related pulmonary hypertension in rats. Methods and Results — In this study we determined the time course of hypoxia-induced serine elastase activity in the murine lung and related this to initiation of a proteolytic cascade characterized by an increase in matrix metalloproteinases (MMPs). We then used transgenic mice in which overexpression of the selective serine elastase inhibitor elafin was targeted to the cardiovascular system to determine whether upregulation of a naturally occurring serine elastase inhibitor suppresses MMPs and the hemodynamic and structural response to chronic hypoxia (air at 380 mm Hg). In nontransgenic but not in elafin-transgenic mice, we documented a transient increase in serine elastase activity after 12 hours of hypoxic exposure attributed to a 30-kDa protein as determined by elastin zymography and fluorophosphonate/fluorophosphate-biotin labeling. Two days after hypoxia, the pro-forms of MMP-2 and MMP-9 were induced in the nontransgenic mice, but MMP-9 was suppressed in elafin-transgenic mice. Acute hypoxic vasoconstriction was similar in nontransgenic and elafin-transgenic littermates. Chronic hypoxia for 26 days resulted in >1-fold increase in right ventricular pressure ( P <0.004) in nontransgenic compared with control or elafin-transgenic littermates. In the latter mice, normalization of the right ventricular pressure was associated with reduced muscularization and preservation of the number of distal vessels ( P <0.04 for both comparisons). Conclusions — Modulation of the severity of chronic hypoxia-induced pulmonary vascular disease could be a function of endogenously expressed serine elastase inhibitors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hc0402.102866

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

Metadata

Authors
Zaidi, S. H. E., You, X.-M., Ciura, S., Husain, M., & Rabinovitch, M.
Venue
Circulation
Published
2002-01-29
Volume
105
Issue
4
Pages
516-521
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2104543099
Cited by
186
References
15
FWCI
5.74
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.