Calmodulin Inhibitor W-7 Unmasks a Novel Electrocardiographic Parameter That Predicts Initiation of Torsade de Pointes
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background — We have shown that the calmodulin inhibitor W-7 suppresses torsade de pointes (TdP) without shortening the QT interval, which is consistent with other findings that QT prolongation, per se, is insufficient to generate TdP. ECGs were analyzed from a well-characterized animal model of TdP to identify more reliable predictors of this life-threatening ventricular arrhythmia. Methods and Results — TdP was induced using methoxamine and clofilium in 12 of 14 rabbits pretreated with vehicle control, whereas pretreatment with W-7 (50 μmol/kg), an inhibitor of the intracellular Ca 2+ -binding protein calmodulin, significantly suppressed TdP induction (1 of 11 rabbits with TdP, P <0.001). W-7 did not affect heart rate, increases in QT intervals, or dispersion compared with measurements in vehicle-treated control animals. However, a progressive and significant increase in the ratio of U-wave to T-wave amplitude (UTA) occurred before TdP onset in control animals, and this was prevented by W-7. Conclusions — Selective suppression of TdP inducibility by W-7, without shortening the duration of cardiac repolarization, allowed identification of the UTA ratio as a new electrocardiographic index for predicting TdP onset. These findings are consistent with the idea that prolonged repolarization is not the proximate cause of arrhythmia initiation, and they suggest that an increased UTA ratio reflects activation of intracellular Ca 2+ /calmodulin–dependent processes that are required for triggering TdP in this model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Haverkamp*, W. (2000) · Cardiovascular Research · doi:10.1016/s0008-6363(00)00119-x · Cited by 486
Cited by
Drug-induced prolongation of the QT interval
Roden, D. M. (2004) · New England Journal of Medicine · doi:10.1056/nejmra032426 · Cited by 1,965
Self-citationQTc Prolongation, Torsades de Pointes, and Psychotropic Medications
Beach, S. R., Celano, C. M., Noseworthy, P. A., Januzzi, J. L., & Huffman, J. C. (2013) · Psychosomatics · doi:10.1016/j.psym.2012.11.001 · Cited by 345
Calmodulin Kinase II and Arrhythmias in a Mouse Model of Cardiac Hypertrophy
Wu, Y., Temple, J., Zhang, R., Dzhura, I., Zhang, W., Trimble, R., Roden, D. M., Passier, R., Olson, E. N., Colbran, R. J., et al. (2002) · Circulation · doi:10.1161/01.cir.0000027583.73268.e7 · Cited by 268
Self-citationHinterseer, M., Thomsen, M. B., Beckmann, B.-M., Pfeufer, A., Schimpf, R., Wichmann, H.-E., Steinbeck, G., Vos, M. A., & Kaab, S. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm586 · Cited by 126
Giant T–U Waves Precede Torsades de Pointes in Long QT Syndrome
Kirchhof, P., Franz, M. R., Bardai, A., & Wilde, A. M. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.03.043 · Cited by 112
Animal models of ventricular arrhythmias
Hamlin, R. L. (2007) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2006.08.006 · Cited by 60
Metadata
- Authors
- Gbadebo, T. D., Trimble, R. W., Khoo, M. S. C., Temple, J., Roden, D. M., & Anderson, M. E.
- Venue
- Circulation
- Published
- 2002-02-12
- Volume
- 105
- Issue
- 6
- Pages
- 770-774
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2139219804
- Cited by
- 81
- References
- 1
- FWCI
- 3.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.