The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Shock Reduction Using Antitachycardia Pacing for Spontaneous Rapid Ventricular Tachycardia in Patients With Coronary Artery Disease
Open accessAbstract
Background Implantable cardioverter-defibrillators (ICDs) can terminate some ventricular tachycardias (VTs) painlessly with antitachycardia pacing (ATP). ATP has not routinely been applied for VT >188 bpm because of concerns about efficacy, risk of acceleration, and delay of definitive shock therapy. This prospective, multicenter study evaluated the efficacy of empirical ATP to terminate fast VT (FVT; >188 bpm). Methods and Results Two hundred twenty coronary artery disease patients received ICDs for standard indications. Empirical, standardized therapy was programmed so that all FVT episodes (average cycle length [CL] 240 to 320 ms, 250 to 188 bpm) were treated with 2 ATP sequences (8-pulse burst pacing train at 88% of the FVT CL) before shock delivery. A total of 1100 episodes of spontaneous ventricular tachyarrhythmias occurred during a mean of 6.9±3.6 months of follow-up. Fifty-seven percent were classified as slow VT (CL≥320 ms), 40% as FVT (240 ms≤CL<320 ms), and 3% as ventricular fibrillation (CL<240 ms). A total of 446 FVT episodes, mean CL=301±24 ms, occurred in 52 patients (median 2 episodes per patient). ATP terminated 396 FVT episodes (89%), with an adjusted efficacy of 77% (95% CI 68% to 83%). VT acceleration caused by ATP occurred in 10 FVT episodes (4%). FVT arrhythmic syncope occurred on 9 occasions (2%) in 4 patients. Conclusions FVT (CL<320 ms) is common in ICD patients. ATP can terminate 3 of 4 of these episodes with a low incidence of acceleration and syncope. ATP for FVT may safely reduce the morbidity of painful shocks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Longitudinal data analysis using generalized linear models
LIANG, K.-Y., & ZEGER, S. L. (1986) · Biometrika · doi:10.1093/biomet/73.1.13 · Cited by 18,550
Models for Longitudinal Data: A Generalized Estimating Equation Approach
Zeger, S. L., Liang, K.-Y., & Albert, P. S. (1988) · Biometrics · doi:10.2307/2531734 · Cited by 4,505
(1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372202 · Cited by 3,232
Clinical Cardiac Electrophysiology: Techniques and Interpretations.
(1980) · Annals of Internal Medicine · doi:10.7326/0003-4819-92-6-880_2 · Cited by 1,051
Schaumann, A., Mühlen, F. V. Z., Herse, B., Gonska, B.-D., & Kreuzer, H. (1998) · Circulation · doi:10.1161/01.cir.97.1.66 · Cited by 160
FROMER, M. A., Brachmann, J., Block, M. S., Siebels, J., Hoffmann, E., Almendral, J. M., Ohm, O., den Dulk, K., Coumel, P., & Camm, A. J. (1992) · Circulation · doi:10.1161/01.cir.86.2.363 · Cited by 122
Bänsch, D., Brunn, J., Castrucci, M., Weber, M., Gietzen, F. H., Borggrefe, M., BREITHARDT, G. E., & Block, M. S. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00543-3 · Cited by 81
Maloney, J. D., Masterson, M., Khoury, D. S., Trohman, R. G., Wilkoff, B. L., Simmons, T. W., Morant, V. A., & CASTLE, L. W. (1991) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1991.tb05107.x · Cited by 76
Gillis, A. M., Leitch, J. W., Sheldon, R. S., Morillo, C. A., Wyse, D. G., Yee, R. K., Klein, G. J., & Mitchell, L. B. (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)90984-k · Cited by 75
Mechanisms of ventricular tachycardia.
Josephson, M. E., Jm, A., Ae, B., & Marchlinski, F. E. (1987) · PubMed · Cited by 69
Raitt, M. H., Dolack, G. L., Kudenchuk, P. J., Poole, J. E., & Bardy, G. H. (1995) · Circulation · doi:10.1161/01.cir.91.7.1996 · Cited by 62
[Mechanisms of ventricular tachycardia].
Clémenty, J., Chéradame, I., Bordier, P., Gosse, P., & POQUET, F. (1993) · PubMed · Cited by 51
Korte, T. (2000) · European Heart Journal · doi:10.1053/euhj.1999.2044 · Cited by 34
Cited by
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Self-citationWriting Committee Members, Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,774
Self-citationEpstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,489
Self-citationWILKOFF, B. L., HESS, M., YOUNG, J., & ABRAHAM, W. T. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03625.x · Cited by 835
Wathen, M. S., DeGroot, P. J., Sweeney, M. O., Stark, A. J., Otterness, M. F., Adkisson, W. O., Canby, R. C., Khalighi, K., Machado, C., Rubenstein, D. S., et al. (2004) · Circulation · doi:10.1161/01.cir.0000145610.64014.e4 · Cited by 775
Self-citation
Metadata
- Authors
- Wathen, M. S., Sweeney, M. O., DeGroot, P. J., Stark, A. J., Koehler, J. L., Chisner, M. B., Machado, C., Adkisson, W. O., & for the PainFREE ℞ Investigators
- Venue
- Circulation
- Published
- 2001-08-14
- Volume
- 104
- Issue
- 7
- Pages
- 796-801
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2104793759
- Cited by
- 333
- References
- 13
- FWCI
- 4.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.