CoChat

Catheter Stimulation of Cardiac Parasympathetic Nerves in Humans: A Novel Approach to the Cardiac Autonomic Nervous System

Schauerte, Patrick, Mischke, Karl, Plisiene, Jurgita, Waldmann, Matthias, Zarse, Markus, Stellbrink, Christoph, Schimpf, Thomas, Knackstedt, Christian, Sinha, Anil, Hanrath, Peter · 2001 · Circulation
Cited by 73

The DOI matches its Crossref record.

Abstract

Background Cardiac parasympathetic nerves run alongside the superior vena cava (SVC) and accumulate particularly epicardially adjacent to the orifice of the coronary sinus (CS). In animals, these nerves can be electrically stimulated inside the SVC or CS, which results in negative chronotropic/dromotropic effects and negative inotropic effects in the atria but not the ventricles. Parasympathetic nerve stimulation (PS) with 20 Hz in the CS, however, also excites the atria, thereby inducing atrial fibrillation. The present study overcomes this limitation by applying high-frequency nerve stimuli within the atrial refractory period. Using this technique, we investigated for the first time whether neurophysiological effects similar to those in animals can be obtained in humans. Methods and Results In 25 patients, parasympathetic nerves were stimulated via a multipolar electrode catheter placed in the SVC (stimulation with 20 Hz; n=14) or CS (pulsed 200-Hz stimuli; n=11). A significant sinus rate decrease and prolongation of the antegrade Wenckebach period was achieved during PS in the SVC. During PS in the CS, a graded-response prolongation of the antegrade Wenckebach interval was observed with increasing PS voltage until third-degree AV block occurred in 8 of 11 patients. The negative chronotropic/dromotropic effects started and terminated immediately after the onset and termination of PS, respectively. Atropine abolished these effects (n=11). Conclusions Human parasympathetic efferent nerve stimulation induces reversible negative chronotropic and dromotropic effects. PS may serve as an adjunctive tool for the diagnosis/treatment of supraventricular tachycardias and may be beneficial for ventricular rate slowing during tachycardic atrial fibrillation in patients with congestive heart failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hc4501.099307

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 73

Metadata

Authors
Schauerte, P., Mischke, K., Plisiene, J., Waldmann, M., Zarse, M., Stellbrink, C., Schimpf, T., Knackstedt, C., Sinha, A., & Hanrath, P.
Venue
Circulation
Published
2001-11-13
Volume
104
Issue
20
Pages
2430-2435
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2137298524
Cited by
73
References
0
FWCI
2.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Catheter Stimulation of Cardiac Parasympathetic Nerves in Humans: A Novel Approach to the Cardiac Autonomic Nervous System. https://app.cochat.ai/papers/10.1161/hc4501.099307
The paper
Schauerte, P., Mischke, K., Plisiene, J., Waldmann, M., Zarse, M., Stellbrink, C., Schimpf, T., Knackstedt, C., Sinha, A., & Hanrath, P. (2001). Catheter Stimulation of Cardiac Parasympathetic Nerves in Humans: A Novel Approach to the Cardiac Autonomic Nervous System. Circulation. https://doi.org/10.1161/hc4501.099307

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.