CoChat

Endovascular Treatment of Intracranial Aneurysms With Guglielmi Detachable Coils: Analysis of Midterm Angiographic and Clinical Outcomes

Open access
Ng, P., Khangure, M.S., Phatouros, C.C., Bynevelt, M., ApSimon, H., McAuliffe, W. · 2002 · Stroke
Cited by 172

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background and Purpose — The previous decade has witnessed increasing application of Guglielmi detachable coils (GDCs) for the treatment of intracranial aneurysms. However, the midterm angiographic and clinical outcomes are not well documented. We report here the angiographic and clinical outcomes of patients treated with GDCs over an 8-year period . Methods — Between 1992 and 1998, 144 patients with 160 intracranial aneurysms were treated with GDCs. Clinical follow-up data were obtained from medical records, questionnaires, and telephone interviews. Angiographic studies were reviewed by 2 neuroradiologists to obtain consensus regarding the degree of aneurysm occlusion. Results — Eighty-one patients had ruptured aneurysms; 63 had unruptured aneurysms. Technical success was achieved in 91% of patients, with complete aneurysm occlusion in 46%, neck remnants in 16%, and residual body filling in 38%. Angiographic follow-up revealed that residual body filling in some aneurysms was resolved, small neck remnants were stable, and the recanalization rate decreased with time. All 63 patients with unruptured aneurysms were discharged from hospital with independent clinical status (Glasgow Outcome Score, 1 or 2). For patients with ruptured aneurysms, discharge clinical status correlated with the Hunt & Hess clinical grade at the time of treatment. Clinical follow-up for a minimum of 2 years was available in 98.5% of patients. Ninety-four percent of patients treated for unruptured aneurysms were independent at 2 years, and 82% of Hunt & Hess grade I to II patients were independent. Conclusions — Coil embolization is a safe and effective treatment for both ruptured and unruptured aneurysms. Increasing angiographic stability is demonstrated in treated aneurysms up to 3 years from coil embolization. Therefore, follow-up angiography until this time is advisable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hs0102.100486

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 172

Metadata

Authors
Ng, P., Khangure, M. S., Phatouros, C. C., Bynevelt, M., ApSimon, H., & McAuliffe, W.
Venue
Stroke
Published
2002-01
Volume
33
Issue
1
Pages
210-217
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2063397830
Cited by
172
References
1
FWCI
9.42
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.