The DOI matches its Crossref record; 322 of the 322 references it cites were found in a registry or an index.
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Open accessAbstract
The accurate measurement of blood pressure (BP) is essential for the diagnosis and management of hypertension. This article provides an updated American Heart Association scientific statement on BP measurement in humans. In the office setting, many oscillometric devices have been validated that allow accurate BP measurement while reducing human errors associated with the auscultatory approach. Fully automated oscillometric devices capable of taking multiple readings even without an observer being present may provide a more accurate measurement of BP than auscultation. Studies have shown substantial differences in BP when measured outside versus in the office setting. Ambulatory BP monitoring is considered the reference standard for out-of-office BP assessment, with home BP monitoring being an alternative when ambulatory BP monitoring is not available or tolerated. Compared with their counterparts with sustained normotension (ie, nonhypertensive BP levels in and outside the office setting), it is unclear whether adults with white-coat hypertension (ie, hypertensive BP levels in the office but not outside the office) have increased cardiovascular disease risk, whereas those with masked hypertension (ie, hypertensive BP levels outside the office but not in the office) are at substantially increased risk. In addition, high nighttime BP on ambulatory BP monitoring is associated with increased cardiovascular disease risk. Both oscillometric and auscultatory methods are considered acceptable for measuring BP in children and adolescents. Regardless of the method used to measure BP, initial and ongoing training of technicians and healthcare providers and the use of validated and calibrated devices are critical for obtaining accurate BP measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Wherever possible, blood pressure was collected in accordance with the American Heart Association guidelines [ 37 ].”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Items 201–322 of 322
Blood pressure measurement in obese patients: comparison between upper arm and forearm measurements
Pierin, Â. M. G., Alavarce, D. C., de Gusmão, J. L., Halpern, A., & Mion, D. (2004) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000132425.25263.ac · Cited by 70
Manual and automated office measurements in relation to awake ambulatory blood pressure monitoring
Godwin, M., Birtwhistle, R., Delva, D., Lam, M., Casson, I., MacDonald, S., & Seguin, R. (2010) · Family Practice · doi:10.1093/fampra/cmq067 · Cited by 68
Automated office blood pressure – being alone and not location is what matters most
Armstrong, D. W. J., Matangi, M. F., Brouillard, D., & Myers, M. G. (2015) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000133 · Cited by 68
Self-citationClark, C. E., Taylor, R. S., Butcher, I., Stewart, M. C. W., Price, J. F., Fowkes, F. G. R., Shore, A. C., & Campbell, J. L. (2016) · British Journal of General Practice · doi:10.3399/bjgp16x684949 · Cited by 67
Reproducibility of ambulatory blood pressure monitoring in daily practice
van der Steen, M. S., Lenders, J. W. M., Graafsma, S. J., den Arend, J., & Thien, T. (1999) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000808 · Cited by 66
Muntner, P., Levitan, E. B., Lynch, A. I., Simpson, L. M., Whittle, J., Davis, B. R., Kostis, J. B., Whelton, P. K., & Oparil, S. (2014) · Journal of Clinical Hypertension · doi:10.1111/jch.12290 · Cited by 65
Self-citationEarly morning hypertension: what does it contribute to overall cardiovascular risk assessment?
Kario, K., & White, W. B. (2008) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2008.05.004 · Cited by 65
Self-citationOffice Blood Pressure Measurement: The Weak Cornerstone of Hypertension Diagnosis
Stergiou, G., Kollias, A., Parati, G., & O’Brien, E. (2018) · Hypertension · doi:10.1161/hypertensionaha.118.10850 · Cited by 64
Bonso, E., Saladini, F., Zanier, A., Benetti, E., Dorigatti, F., & Palatini, P. (2010) · Hypertension Research · doi:10.1038/hr.2010.146 · Cited by 63
Reproducibility of ambulatory blood pressure in treated and untreated hypertensive patients
Eguchi, K., Hoshide, S., Hoshide, Y., Ishikawa, S., Shimada, K., & Kario, K. (2010) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283378477 · Cited by 60
Myers, M. G., Kaczorowski, J. A., Dolovich, L. R., Tu, K., & Paterson, J. M. (2016) · Hypertension · doi:10.1161/hypertensionaha.116.07721 · Cited by 60
Self-citationPoor Reliability of Wrist Blood Pressure Self-Measurement at Home
Casiglia, E., Tikhonoff, V., Albertini, F., et al. (2016) · Hypertension · doi:10.1161/hypertensionaha.116.07961 · Cited by 60
Cook, A. J., Anderson, M. L., Catz, S. L., Fishman, P. A., Carlson, J., Johnson, R., Green, B. B., & Ralston, J. D. (2014) · Applied Clinical Informatics · doi:10.4338/aci-2013-10-ra-0079 · Cited by 59
Viera, A. J., Lingley, K., & Hinderliter, A. L. (2011) · BMC Medical Research Methodology · doi:10.1186/1471-2288-11-59 · Cited by 59
Self-citationAdherence to Blood Pressure Telemonitoring in a Cluster‐Randomized Clinical Trial
Kerby, T. J., Asche, S. E., Maciosek, M. V., O’Connor, P. J., Sperl‐Hillen, J. M., & Margolis, K. L. (2012) · Journal of Clinical Hypertension · doi:10.1111/j.1751-7176.2012.00685.x · Cited by 58
Reproducibility of blood pressure dipping: Relation to day-to-day variability in sleep quality
Hinderliter, A. L., Routledge, F. S., Blumenthal, J. A., Koch, G. G., Hussey, M. A., Wohlgemuth, W. K., & Sherwood, A. (2013) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2013.06.001 · Cited by 58
Chan, P., Wong, C., Pun, L., Wong, Y., Wong, M. M., Chu, D. W., & Siu, C. (2017) · BMJ Open · doi:10.1136/bmjopen-2016-013685 · Cited by 58
Optimum frequency of office blood pressure measurement using an automated sphygmomanometer
Myers, M. G., Valdivieso, M., & KISS, A. J. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283104247 · Cited by 57
Self-citationThe optimal home blood pressure monitoring schedule based on the Didima outcome study
Stergiou, G. S., Nasothimiou, E. G., Kalogeropoulos, P. G., Pantazis, N., & Baibas, N. M. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2009.54 · Cited by 56
Staessen, J. A., Thijs, L., Ohkubo, T., Kikuya, M., Richart, T., Boggia, J., Adiyaman, A., Dechering, D. G., Kuznetsova, T., Thien, T., et al. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283108f93 · Cited by 56
Umaña, E., Ahmed, W., Fraley, M. A., & Alpert, M. (2006) · Angiology · doi:10.1177/000331970605700106 · Cited by 56
Stergiou, G. S., Nasothimiou, E. G., Destounis, A., Poulidakis, E., Evagelou, I., & Tzamouranis, D. (2012) · American Journal of Hypertension · doi:10.1038/ajh.2012.82 · Cited by 55
de la Sierra, A., Vinyoles, E., Banegas, J., Segura, J., Gorostidi, M., de la Cruz, J. D., & Ruilope, L. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001493 · Cited by 54
Martina, J. R., Westerhof, B. E., van Goudoever, J., et al. (2010) · ASAIO Journal · doi:10.1097/mat.0b013e3181d70227 · Cited by 53
Campbell, N. R. C., McKay, D. W., Conradson, H. E., et al. (2007) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1002190 · Cited by 53
Booth, J. N., Muntner, P., Abdalla, M., Diaz, K. M., Viera, A. J., Reynolds, K., Schwartz, J. E., & Shimbo, D. (2015) · Journal of Hypertension · doi:10.1097/hjh.0000000000000791 · Cited by 52
Self-citation(2017) · PubMed Central · Cited by 52
Visit-to-Visit Variability of BP and CKD Outcomes
Whittle, J., Lynch, A. I., Tanner, R. M., Simpson, L. M., Davis, B. R., Rahman, M., Whelton, P. K., Oparil, S., & Muntner, P. (2016) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.04660415 · Cited by 51
Self-citationde la Sierra, A., Vinyoles, E., Banegas, J. R., Parati, G., de la Cruz, J. J., Gorostidi, M., Segura, J., & Ruilope, L. M. (2016) · Journal of Clinical Hypertension · doi:10.1111/jch.12792 · Cited by 51
Irving, G., Holden, J., Stevens, R., & McManus, R. J. (2016) · BMJ Open · doi:10.1136/bmjopen-2016-012429 · Cited by 51
Blood pressure during siesta: effect on 24-h ambulatory blood pressure profiles analysis
Stergiou, G. S., Malakos, J., Zourbaki, A. S., et al. (1997) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000383 · Cited by 50
Sphygmomanometer calibration--why, how and how often?
Turner, M. J., Speechly, C., & Bignell, N. (2007) · PubMed · Cited by 49
Ishikuro, M., Obara, T., Metoki, H., Ohkubo, T., Yamamoto, M., Akutsu, K., Sakurai, K., Iwama, N., Katagiri, M., Yagihashi, K., et al. (2012) · American Journal of Hypertension · doi:10.1093/ajh/hps002 · Cited by 48
Is Isolated Nocturnal Hypertension A Reproducible Phenotype?
Abdalla, M., Goldsmith, J., Muntner, P., Diaz, K. M., Reynolds, K., Schwartz, J., & Shimbo, D. (2016) · American Journal of Hypertension · doi:10.1093/ajh/hpv058 · Cited by 46
Self-citationAltunkan, Ş., Ilman, N., & Altunkan, E. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3282f3fb50 · Cited by 46
Reproducibility of masked hypertension among adults 30 years or older
Viera, A. J., Lin, F., Tuttle, L. A., Olsson, E., Stankevitz, K., Girdler, S. S., Klein, J. L., & Hinderliter, A. L. (2014) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000054 · Cited by 46
Self-citationAccuracy of ambulatory blood pressure monitors
Hodgkinson, J., Sheppard, J. P., Heneghan, C. J., Martin, U., Mant, J., Roberts, N. W., & McManus, R. J. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e32835b8d8b · Cited by 45
Comparative Assessment of Four Blood Pressure Measurement Methods in Hypertensives
Lamarre-Cliché, M., Cheong, N. N., & Larochelle, P. M. (2011) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2011.05.001 · Cited by 44
Ambulatory Blood Pressure Monitoring: How Reproducible Is It?
Musso, N. R. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00126-x · Cited by 44
The Use of Ambulatory Blood Pressure Monitoring Among Medicare Beneficiaries in 2007-2010
Shimbo, D., Kent, S. T., Diaz, K. M., Huang, L., Viera, A., Kilgore, M., Oparil, S., & Muntner, P. (2014) · Journal of the American Society of Hypertension : JASH · doi:10.1016/j.jash.2014.09.015 · Cited by 43
Self-citationThresholds for Ambulatory Blood Pressure among African Americans in the Jackson Heart Study
Ravenell, J., Shimbo, D., Booth, J., Sarpong, D., Agyemang, C., Moody, D. L. B., Abdalla, M., Spruill, T., Shallcross, A. J., Bress, A., et al. (2017) · Circulation · doi:10.1161/circulationaha.116.027051 · Cited by 43
Self-citationThe optimal schedule for self-monitoring of blood pressure by patients at home
Stergiou, G., & Parati, G. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282efc17d · Cited by 42
Comparison of two automated sphygmomanometers for use in the office setting
Myers, M. G., Valdivieso, M., Kiss, A., & Tobe, S. W. (2009) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32831e314f · Cited by 42
Self-citationBenmira, A. M., Pérez‐Martin, A., Schuster, I., Aichoun, I., Coudray, S., Bereksi-Reguig, F., & Dauzat, M. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2016.1128821 · Cited by 42
Dobson, R. T., Taylor, J., Henry, C. J., et al. (2009) · Research in Social and Administrative Pharmacy · doi:10.1016/j.sapharm.2008.11.002 · Cited by 41
Chio, S., Urbina, E. M., LaPointe, J., Tsai, J., & Berenson, G. S. (2011) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2010.10.005 · Cited by 39
Self-citationMuntner, P., Levitan, E. B., Reynolds, K., Mann, D. M., Tonelli, M. A., Oparil, S., & Shimbo, D. (2012) · Journal of Clinical Hypertension · doi:10.1111/j.1751-7176.2011.00581.x · Cited by 38
Self-citationTislér, A., Dunai, A., Keszei, A. P., Fekete, B., Othmane, T., Torzsa, P., & Logan, A. G. (2006) · Journal of Hypertension · doi:10.1097/01.hjh.0000242396.15097.f3 · Cited by 38
Graves, J., Bailey, K., & Sheps, S. (2003) · Blood Pressure Monitoring · doi:10.1097/00126097-200312000-00001 · Cited by 38
Sorof, J. M., Turner, J., Franco, K., & Portman, R. J. (2004) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2003.12.047 · Cited by 37
Myers, M. G., Valdivieso, M., Chessman, M., & Kiss, A. (2010) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e328340d128 · Cited by 37
Self-citationNoninvasive assessment of arterial pressure
Chemla, D. S., Teboul, J., & Richard, C. M. (2008) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e3282fd6e31 · Cited by 36
Inter‐arm blood pressure differences in pregnant women
Poon, L. C., Kametas, N. A., Strobl, I., Pachoumi, C., & Nicolaides, K. H. (2008) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2008.01756.x · Cited by 35
Evaluation of an automated sphygmomanometer for use in the office setting
Myers, M., & Valdivieso, M. (2012) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283540785 · Cited by 35
Self-citationThomas, S. J., Booth, J. N., Bromfield, S. G., Seals, S. R., Spruill, T. M., Ogedegbe, G. G., Kidambi, S., Shimbo, D., Calhoun, D. A., & Muntner, P. (2017) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2017.02.001 · Cited by 35
Self-citationAlbasri, A., O’Sullivan, J. W., Roberts, N. W., Prinjha, S., McManus, R. J., & Sheppard, J. P. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001443 · Cited by 35
Wright, J. C., & Looney, S. W. (1997) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000431 · Cited by 34
Self-citationKent, S. T., Shimbo, D., Huang, L., Diaz, K. M., Viera, A., Kilgore, M., Oparil, S., & Muntner, P. (2014) · Journal of the American Society of Hypertension : JASH · doi:10.1016/j.jash.2014.09.020 · Cited by 34
Self-citationPrimary care physician beliefs regarding usefulness of self-monitoring of blood pressure
Cheng, C., Studdiford, J. S., Diamond, J. J., & Chambers, C. V. (2003) · Blood Pressure Monitoring · doi:10.1097/00126097-200312000-00005 · Cited by 34
Blood pressure measurement: arm circumference and cuff size availability
Veiga, E. V., Arcuri, E. A. M., Cloutier, L., & Santos, J. L. F. (2009) · Revista Latino-Americana de Enfermagem · doi:10.1590/s0104-11692009000400004 · Cited by 34
Properties of the random zero sphygmomanometer.
Kronmal, R. A., Rutan, G. H., Manolio, T. A., & Borhani, N. O. (1993) · Hypertension · doi:10.1161/01.hyp.21.5.632 · Cited by 34
Ambulatory blood pressure in the hypertensive population
Owens, P., Lyons, S., & O'Brien, E. T. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816120-00005 · Cited by 34
Tissue-Informative Mechanism for Wearable Non-invasive Continuous Blood Pressure Monitoring
Woo, S. H., Choi, Y. Y., Kim, D. J., Bien, F. D., & Kim, J. J. (2014) · Scientific Reports · doi:10.1038/srep06618 · Cited by 31
Padwal, R. S., Townsend, R. R., Trudeau, L., Hamilton, P. G., & Gelfer, M. (2014) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2014.11.004 · Cited by 30
Self-citationIs white-coat hypertension associated with increased cardiovascular and mortality risk?
Muntner, P., Booth, J. N., Shimbo, D., & Schwartz, J. E. (2016) · Journal of Hypertension · doi:10.1097/hjh.0000000000000983 · Cited by 30
Self-citationWeir, M. R. (2014) · Annals of Internal Medicine · doi:10.7326/0003-4819-161-11-201412020-01006 · Cited by 29
de Almeida, F. A., Pavan, M., & Rodrigues, C. (2009) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2009.02353.x · Cited by 28
Staessen, J. A., & Thijs, L. (2000) · PubMed · Cited by 28
Side effects of ambulatory blood pressure monitoring
van der Steen, M. S., Lenders, J. W. M., & Thien, T. A. (2005) · Blood Pressure Monitoring · doi:10.1097/00126097-200506000-00007 · Cited by 27
Sample size for short‐term trials of antihypertensive drugs.
Freestone, S. H., Silas, J., & Ramsay, L. (1982) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1982.tb01971.x · Cited by 26
Kawabe, H., & Saito, I. (2007) · Hypertension Research · doi:10.1291/hypres.30.845 · Cited by 24
Sendra‐Lillo, J., Sabater‐Hernández, D., Sendra-Ortolá, A., & Martínez-Martínez, F. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2011.207 · Cited by 24
Mean mid-arm circumference and blood pressure cuff sizes for US adults
Ostchega, Y., Hughes, J. P., Zhang, G., et al. (2013) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283617606 · Cited by 24
Differences between office and 24-hour ambulatory blood pressure measurement during pregnancy
Churchill, D. N., & Beevers, D. G. (1996) · Obstetrics and Gynecology · doi:10.1016/0029-7844(96)00192-5 · Cited by 23
Roubsanthisuk, W., Wongsurin, U., Saravich, S., et al. (2007) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3280b08317 · Cited by 22
Pomini, F., Scavo, M., Ferrazzani, S., Carolis, S. D., Caruso, A., & Mancuso, S. (2001) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/714052781 · Cited by 22
Viera, A. J., Lin, F., Tuttle, L. A., Shimbo, D., Diaz, K. M., Olsson, E., Stankevitz, K., & Hinderliter, A. L. (2014) · American Journal of Hypertension · doi:10.1093/ajh/hpu099 · Cited by 22
Self-citationMagnitude of the White-Coat Effect in the Community Pharmacy Setting: The MEPAFAR Study
Sabater‐Hernández, D., Sierra, A., Sánchez‐Villegas, P., Baena, M. I., Amariles, P., Faus, M. J., & workgroup, O. B. O. T. M. S. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2011.68 · Cited by 22
Matossian, D. (2018) · Pediatric Annals · doi:10.3928/19382359-20181119-01 · Cited by 22
Public-use blood pressure measurement: the kiosk quandary
Alpert, B. S., Dart, R. A., & Sica, D. A. (2014) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2014.07.034 · Cited by 21
Reference values for ambulatory blood pressure: a population study.
Staessen, J. A., Bulpitt, C. J., Fagard, R. H., et al. (1991) · PubMed · Cited by 21
Comparison of the white-coat effect in community pharmacy versus the physician's office
Sendra‐Lillo, J., Sabater‐Hernández, D., Sendra-Ortolá, A., et al. (2011) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e328344c755 · Cited by 21
Pawloski, P. A., Asche, S. E., Trower, N. K., Bergdall, A. R., Dehmer, S. P., Maciosek, M. V., Nyboer, R. A., O’Connor, P. J., Sperl‐Hillen, J. M., Green, B. B., et al. (2016) · Journal of Clinical Pharmacy and Therapeutics · doi:10.1111/jcpt.12414 · Cited by 21
Harju, J., Vehkaoja, A. T., Kumpulainen, P. S., et al. (2017) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-017-9984-3 · Cited by 21
Blood pressure measurement in pregnant women in the left lateral recumbent position
Goldkrand, J. W., & Jackson, M. J. (1997) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(97)70562-3 · Cited by 20
Comparability of Automated Office Blood Pressure to Daytime 24-Hour Ambulatory Blood Pressure
Ringrose, J., Cena, J., Ip, S., Morales, F., Hamilton, P. G., & Padwal, R. S. (2017) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2017.09.022 · Cited by 20
Validation protocols for blood pressure-measuring devices
Beime, B., Deutsch, C., Gomez, T., et al. (2015) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000150 · Cited by 19
Stergiou, G. S., Lourida, P., & Tzamouranis, D. (2011) · Journal of Human Hypertension · doi:10.1038/jhh.2010.107 · Cited by 18 · cited 1×
“Thus, although convenient for the consumer, wrist monitors provide many challenges with precision, and strong reservations have been raised about their use in routine clinical practice, unless measurements in the upper arm are not feasible.(224,225)”
BackgroundMasiero, S., Saladini, F., Benetti, E., et al. (2011) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e328344c73c · Cited by 18
Screening For Hypertension Annually Compared With Current Practice
Garrison, G. M., & Oberhelman, S. S. (2013) · The Annals of Family Medicine · doi:10.1370/afm.1467 · Cited by 18
The Reproducibility of Racial Differences in Ambulatory Blood Pressure Phenotypes and Measurements
Husain, A., Lin, F., Tuttle, L. A., Olsson, E., & Viera, A. J. (2017) · American Journal of Hypertension · doi:10.1093/ajh/hpx079 · Cited by 18
Self-citationPrevalence and characteristics of pseudohypertension in patients with “resistant hypertension”
Kleman, M., Dhanyamraju, S., & Difilippo, W. (2013) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2013.05.006 · Cited by 17
Pomini, F., Scavo, M., Ferrazzani, S., et al. (2001) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/jmf.10.6.398.403 · Cited by 17
The Dilemma of Nocturnal Blood Pressure
Xu, T., Zhang, Y., & Tan, X. (2012) · Journal of Clinical Hypertension · doi:10.1111/jch.12003 · Cited by 16
A novel and simple protocol for the validation of home blood pressure monitors in clinical practice
Eguchi, K., Kuruvilla, S., Ishikawa, J., et al. (2012) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e328356e196 · Cited by 16
Pan, F., Zheng, D., He, P., et al. (2014) · Medicine · doi:10.1097/md.0000000000000301 · Cited by 15
Liu, C., Griffiths, C. J., Murray, A., & Zheng, D. (2016) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000175 · Cited by 15
Unvalidated blood pressure devices with small cuffs are being used in hospitals
Thomas, M., Radford, T., & Dasgupta, I. (2001) · BMJ · doi:10.1136/bmj.323.7309.398/a · Cited by 14
Tasker, F., de Greeff, A., & Shennan, A. H. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2009.113 · Cited by 14
Four-Year Test-Retest Reliability of Self-measured Blood Pressure
Brody, S., Veit, R., & Rau, H. (1999) · Archives of Internal Medicine · doi:10.1001/archinte.159.9.1007 · Cited by 12
Evaluation of the hypertensive state in treated patients
Sabater‐Hernández, D., Sánchez‐Villegas, P., Lacampa, P., et al. (2011) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e328346a856 · Cited by 12
The validity of blood pressure kiosk validation studies
Hamarneh, Y. N. A., Houle, S. K. D., Chatterley, P., et al. (2013) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e328360fb85 · Cited by 12
Blood Pressure Measurements in Patients With Takayasu Arteritis: A Work of Caution
Hafner, F., Froehlich, H., Gary, T., et al. (2012) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2011.09.017 · Cited by 12
Scisney‐Matlock, M., Grand, A., Steigerwalt, S. P., & Normolle, D. P. (2009) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283263064 · Cited by 11
Stergiou, G. S., Karpettas, N., Κόλλιας, Α., et al. (2011) · Journal of Human Hypertension · doi:10.1038/jhh.2011.77 · Cited by 11
Deutsch, C., Krüger, R., Saito, K., Yamashita, S., Sawanoi, Y., Beime, B., & Bramlage, P. (2014) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000063 · Cited by 11
Using Hawksley Random Zero Sphygmomanometer as a Gold Standard May Result in Misleading Conclusions
Conroy, R. M., Atkins, N., Mee, F. D., et al. (1994) · Blood Pressure · doi:10.3109/08037059409102275 · Cited by 10
World Hypertension League Position on Public Use of Blood Pressure Kiosks
Campbell, N. R. C., Niebylski, M. L., Redburn, K. A., et al. (2015) · Journal of Clinical Hypertension · doi:10.1111/jch.12671 · Cited by 9
Can blood pressure measurements taken in the physician’s office avoid the ‘white coat’ bias?
Espinosa, R., Spruill, T. M., Zawadzki, M. J., Vandekar, L., García‐Vera, M. P., Sanz, J., Pickering, T. G., Linden, W., & Gerin, W. (2011) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32834b45d2 · Cited by 9
How to Cope With Unreliable Office Blood Pressure Measurement?
Stergiou, G. S. (2005) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.07.014 · Cited by 8
Unmet needs in the measurement of blood pressure in primary care
Zaheer, S., Watson, L., & Webb, N. J. A. (2014) · Archives of Disease in Childhood · doi:10.1136/archdischild-2013-305277 · Cited by 8
Benmira, A. M., Pérez‐Martin, A., Coudray, S., Schuster, I., Aichoun, I., Laurent, J., Bereski-Reguig, F., & Dauzat, M. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001252 · Cited by 8
Sabater‐Hernández, D., Sánchez‐Villegas, P., García‐Corpas, J. P., Amariles, P., Sendra‐Lillo, J., & Faus, M. J. (2011) · International Journal of Clinical Pharmacy · doi:10.1007/s11096-011-9514-1 · Cited by 7
Vargas, C. G. C., Rios, V. P., Troyo‐Sanromán, R., & Grover‐Páez, F. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200110000-00001 · Cited by 7
Tholl, U., Anlauf, M., Lichtblau, U., et al. (2006) · DMW - Deutsche Medizinische Wochenschrift · doi:10.1055/s-2006-955060 · Cited by 6
Cuff size influences blood pressure measurement in obese children and adolescents.
Muhamed, P. K., Olsen, M. H., Holm, J., et al. (2016) · PubMed · Cited by 6
Walson, P. D. (2016) · Springer eBooks · doi:10.1007/978-3-319-31420-4 · Cited by 6
The Hawksley random zero sphygmomanometer. Should be abandoned.
Lawson, M., & Johnston, A. (1993) · BMJ · doi:10.1136/bmj.307.6896.123 · Cited by 5
Idzenga, T., Reesink, K. D., van Swelm, Y. W. J., Hansen, H. H. G., Holewijn, S., & de Korte, C. L. (2012) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.07.004 · Cited by 5
Blood Pressure Measurement During Pregnancy: Auscultatory Versus Oscillatory Methods
Green, L. A., & Froman, R. D. (1996) · Journal of Obstetric, Gynecologic & Neonatal Nursing · doi:10.1111/j.1552-6909.1996.tb02419.x · Cited by 4
Validation and Reliability Testing of Blood Pressure Monitors
Atkins, N., & O'Brien, E. T. (2015) · Springer eBooks · doi:10.1007/978-3-319-22771-9_5 · Cited by 4
Ambulatory Monitoring of Blood Pressure: An Overview of Devices, Analyses, and Clinical Utility
White, W. B., & Barber, V. (2015) · Springer eBooks · doi:10.1007/978-3-319-22771-9_4 · Cited by 1
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Stergiou, G. S., Palatini, P., Parati, G., O’Brien, E., Januszewicz, A., Lurbe, E., Persu, A., Mancia, G., Kreutz, R., & on behalf of the European Society of Hypertension Council and the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability (2021) · Journal of Hypertension · doi:10.1097/hjh.0000000000002843 · Cited by 859
Jones, D. W., Ferdinand, K. C., Taler, S. J., Johnson, H. M., Shimbo, D., Abdalla, M., Altieri, M. M., Bansal, N., Bello, N. A., Bress, A. P., et al. (2025) · JACC · doi:10.1016/j.jacc.2025.05.007 · Cited by 280
Self-citationFlynn, J. T., Urbina, E. M., Brady, T. M., Baker-Smith, C., Daniels, S. R., Hayman, L. L., Mitsnefes, M., Tran, A., Zachariah, J. P., & on behalf of the Atherosclerosis, H. (2022) · Hypertension · doi:10.1161/hyp.0000000000000215 · Cited by 202
Self-citationYe, N., Jardine, M. J., Oshima, M., Hockham, C., Heerspink, H. J. L., Agarwal, R., Bakris, G., Schutte, A. E., Arnott, C., Chang, T. I., et al. (2021) · Circulation · doi:10.1161/circulationaha.120.048740 · Cited by 115
Drawz, P. E., Agarwal, A., Dwyer, J. P., Horwitz, E., Lash, J., Lenoir, K., McWilliams, A., Oparil, S., Rahbari-Oskoui, F., Rahman, M., et al. (2020) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2020.5028 · Cited by 105
Metadata
- Authors
- Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., Urbina, E. M., Viera, A. J., White, W. B., Wright, J. T., & on behalf of the American Heart Association Council on Hypertension; Council on Cardiovascular Disease in the Young; Council on Cardiovascular and Stroke Nursing; Council on Cardiovascular Radiology and Intervention; Council on Clinical Cardiology; and Council on Quality of Care and Outcomes Research
- ORCID
- Venue
- Hypertension
- Published
- 2019-05
- Volume
- 73
- Issue
- 5
- Pages
- e35-e66
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- PMC
- PMC11409525
- OpenAlex
- W2920258695
- Cited by
- 1,512
- References
- 322
- Citations by year
- 2026: 209 · 2025: 255 · 2024: 240 · 2023: 190 · 2022: 223 · 2021: 199 · 2020: 139 · 2019: 52
- FWCI
- 27.73
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Hypertension (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- American Heart Association
- European Society of Cardiology
- National Institutes of Health (UL1TR001070)
- Office of Science
- National Heart, Lung, and Blood Institute (R01HL098967)
- National Institute of Diabetes and Digestive and Kidney Diseases (R01DK107870, R56DK107870)
- National Center for Research Resources (UL1RR025755)
- National Center for Advancing Translational Sciences
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- blood pressure measurement, hypertension diagnosis, oscillometric blood pressure devices, auscultatory method, ambulatory blood pressure monitoring, home blood pressure monitoring, white coat hypertension, masked hypertension, nocturnal blood pressure, cardiovascular risk, children and adolescents, technician training, device calibration
- MeSH terms
- American Heart Association, Blood Pressure, Blood Pressure Determination, Humans, Hypertension, United States, Disease Management, Consensus
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review