The DOI matches its Crossref record; 322 of the 322 references it cites were found in a registry or an index.
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Open accessAbstract
The accurate measurement of blood pressure (BP) is essential for the diagnosis and management of hypertension. This article provides an updated American Heart Association scientific statement on BP measurement in humans. In the office setting, many oscillometric devices have been validated that allow accurate BP measurement while reducing human errors associated with the auscultatory approach. Fully automated oscillometric devices capable of taking multiple readings even without an observer being present may provide a more accurate measurement of BP than auscultation. Studies have shown substantial differences in BP when measured outside versus in the office setting. Ambulatory BP monitoring is considered the reference standard for out-of-office BP assessment, with home BP monitoring being an alternative when ambulatory BP monitoring is not available or tolerated. Compared with their counterparts with sustained normotension (ie, nonhypertensive BP levels in and outside the office setting), it is unclear whether adults with white-coat hypertension (ie, hypertensive BP levels in the office but not outside the office) have increased cardiovascular disease risk, whereas those with masked hypertension (ie, hypertensive BP levels outside the office but not in the office) are at substantially increased risk. In addition, high nighttime BP on ambulatory BP monitoring is associated with increased cardiovascular disease risk. Both oscillometric and auscultatory methods are considered acceptable for measuring BP in children and adolescents. Regardless of the method used to measure BP, initial and ongoing training of technicians and healthcare providers and the use of validated and calibrated devices are critical for obtaining accurate BP measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Wherever possible, blood pressure was collected in accordance with the American Heart Association guidelines [ 37 ].”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
RETRACTED: Relationship between Clinic and Ambulatory Blood-Pressure Measurements and Mortality
Banegas, J. R., Ruilope, L. M., de la Sierra, A., Vinyoles, E., Gorostidi, M., de la Cruz, J. J., Ruiz-Hurtado, G., Segura, J., Rodríguez-Artalejo, F., & Williams, B. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1712231 · Cited by 490
Retracted2013 ESH/ESC Guidelines for the management of arterial hypertension
Authors Task Force Members, Mancia, G., Fagard, R., Narkiewicz, K., Redon, J., Zanchetti, A., Böhm, M., Christiaens, T., Cífková, R., Backer, G. D., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,739
2018 ESC/ESH Guidelines for the management of arterial hypertension
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy339 · Cited by 10,286
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000065 · Cited by 7,391
Self-citationStone, N. J., Robinson, J. G., Lichtenstein, A. H., Bairey Merz, C. N., Blum, C. B., Eckel, R. H., Goldberg, A. C., Gordon, D., Levy, D., Lloyd-Jones, D. M., et al. (2014) · Circulation · doi:10.1161/01.cir.0000437738.63853.7a · Cited by 7,081
Self-citationA Randomized Trial of Intensive versus Standard Blood-Pressure Control
The SPRINT Research Group (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1511939 · Cited by 6,325
Flynn, J. T., Kaelber, D. C., Baker-Smith, C. M., Blowey, D., Carroll, A. E., Daniels, S. R., de Ferranti, S. D., Dionne, J. M., Falkner, B., Flinn, S. K., et al. (2017) · Pediatrics · doi:10.1542/peds.2017-1904 · Cited by 3,651
Self-citationDahlöf, B., Sever, P. S., Poulter, N. R., Wedel, H., Beevers, D. G., Caulfield, M., Collins, R., Kjeldsen, S. E., Kristinsson, A., McInnes, G. T., et al. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67185-1 · Cited by 2,909
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Cited by
Sorted by citations
Stergiou, G. S., Palatini, P., Parati, G., O’Brien, E., Januszewicz, A., Lurbe, E., Persu, A., Mancia, G., Kreutz, R., & on behalf of the European Society of Hypertension Council and the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability (2021) · Journal of Hypertension · doi:10.1097/hjh.0000000000002843 · Cited by 859
Jones, D. W., Ferdinand, K. C., Taler, S. J., Johnson, H. M., Shimbo, D., Abdalla, M., Altieri, M. M., Bansal, N., Bello, N. A., Bress, A. P., et al. (2025) · JACC · doi:10.1016/j.jacc.2025.05.007 · Cited by 280
Self-citationFlynn, J. T., Urbina, E. M., Brady, T. M., Baker-Smith, C., Daniels, S. R., Hayman, L. L., Mitsnefes, M., Tran, A., Zachariah, J. P., & on behalf of the Atherosclerosis, H. (2022) · Hypertension · doi:10.1161/hyp.0000000000000215 · Cited by 202
Self-citationYe, N., Jardine, M. J., Oshima, M., Hockham, C., Heerspink, H. J. L., Agarwal, R., Bakris, G., Schutte, A. E., Arnott, C., Chang, T. I., et al. (2021) · Circulation · doi:10.1161/circulationaha.120.048740 · Cited by 115
Drawz, P. E., Agarwal, A., Dwyer, J. P., Horwitz, E., Lash, J., Lenoir, K., McWilliams, A., Oparil, S., Rahbari-Oskoui, F., Rahman, M., et al. (2020) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2020.5028 · Cited by 105
Cuffless Blood Pressure Monitoring: Promises and Challenges
Pandit, J. A., Lores, E., & Batlle, D. (2020) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.03680320 · Cited by 101
International Consensus on Standardized Clinic Blood Pressure Measurement – A Call to Action
Cheung, A. K., Whelton, P. K., Muntner, P., Schutte, A. E., Moran, A. E., Williams, B., Sarafidis, P., Chang, T. I., Daskalopoulou, S. S., Flack, J. M., et al. (2023) · The American Journal of Medicine · doi:10.1016/j.amjmed.2022.12.015 · Cited by 96
Self-citationFormulas to Explain Popular Oscillometric Blood Pressure Estimation Algorithms
Chandrasekhar, A., Yavarimanesh, M., Hahn, J.-O., Sung, S.-H., Chen, C.-H., Cheng, H.-M., & Mukkamala, R. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01415 · Cited by 84
TensioBot: a chatbot assistant for self-managed in-house blood pressure checking
Echeazarra, L., Pereira, J., & Saracho, R. (2021) · Journal of Medical Systems · doi:10.1007/s10916-021-01730-x · Cited by 66
de Lemos, J. A., Linetzky, B., le Roux, C. W., Laffin, L. J., Vongpatanasin, W., Fan, L., Hemmingway, A., Ahmad, N. N., Bunck, M. C., & Stefanski, A. (2024) · Hypertension · doi:10.1161/hypertensionaha.123.22022 · Cited by 64
Goupil, R., Tsuyuki, R. T., Santesso, N., Terenzi, K. A., Habert, J., Cheng, G., Gysel, S. C., Bruneau, J., Leung, A. A., Campbell, N. R. C., et al. (2025) · Canadian Medical Association Journal · doi:10.1503/cmaj.241770 · Cited by 60
Severin, R., Sabbahi, A., Albarrati, A., Phillips, S. A., & Arena, S. (2020) · Physical Therapy · doi:10.1093/ptj/pzaa034 · Cited by 43
Human Errors in Automated Office Blood Pressure Measurement: Still Room for Improvement
Elias, M. F., & Goodell, A. L. (2021) · Hypertension · doi:10.1161/hypertensionaha.120.16164 · Cited by 31
Sakhuja, S., Jaeger, B. C., Akinyelure, O. P., Bress, A. P., Shimbo, D., Schwartz, J. E., Hardy, S. T., Howard, G., Drawz, P., & Muntner, P. (2022) · The Journal of Clinical Hypertension · doi:10.1111/jch.14418 · Cited by 28
Self-citationSafety of exercise for adults with thoracic aortic aneurysms and dissections
Li, J., Boyd, A., Huang, M., Berookhim, J., & Prakash, S. K. (2022) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2022.888534 · Cited by 13
Shantharam, S. S., Mahalingam, M., Rasool, A., Reynolds, J. A., Bhuiya, A. R., Satchell, T. D., Chapel, J. M., Hawkins, N. A., Jones, C. D., Jacob, V., et al. (2022) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2021.06.025 · Cited by 13
Rogers, E. M., Banks, N. F., Tomko, P. M., Sciarrillo, C. M., Emerson, S. R., Thomas, E. B. K., Taylor, A., Teague, T. K., & Jenkins, N. D. M. (2023) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00524.2022 · Cited by 11
Currie, K. D., Soave, K. M., & Slade, J. M. (2023) · Journal of Human Hypertension · doi:10.1038/s41371-021-00623-3 · Cited by 11
Automated blood pressure measuring devices: how are they clinically validated for accuracy?
Ringrose, J. S., & Padwal, R. (2022) · Journal of Human Hypertension · doi:10.1038/s41371-022-00761-2 · Cited by 9
Banks, N. F., Rogers, E. M., Helwig, N. J., Schwager, L. E., Alpers, J. P., Schulte, S. L., Trachta, E. R., Lockwood, C. M., & Jenkins, N. D. M. (2024) · Journal of the International Society of Sports Nutrition · doi:10.1080/15502783.2023.2297988 · Cited by 4
“Wherever possible, blood pressure was collected in accordance with the American Heart Association guidelines [37].”
Method
Metadata
- Authors
- Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., Urbina, E. M., Viera, A. J., White, W. B., Wright, J. T., & on behalf of the American Heart Association Council on Hypertension; Council on Cardiovascular Disease in the Young; Council on Cardiovascular and Stroke Nursing; Council on Cardiovascular Radiology and Intervention; Council on Clinical Cardiology; and Council on Quality of Care and Outcomes Research
- ORCID
- Venue
- Hypertension
- Published
- 2019-05
- Volume
- 73
- Issue
- 5
- Pages
- e35-e66
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- PMC
- PMC11409525
- OpenAlex
- W2920258695
- Cited by
- 1,512
- References
- 322
- Citations by year
- 2026: 209 · 2025: 255 · 2024: 240 · 2023: 190 · 2022: 223 · 2021: 199 · 2020: 139 · 2019: 52
- FWCI
- 27.73
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Hypertension (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- American Heart Association
- European Society of Cardiology
- National Institutes of Health (UL1TR001070)
- Office of Science
- National Heart, Lung, and Blood Institute (R01HL098967)
- National Institute of Diabetes and Digestive and Kidney Diseases (R01DK107870, R56DK107870)
- National Center for Research Resources (UL1RR025755)
- National Center for Advancing Translational Sciences
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- blood pressure measurement, hypertension diagnosis, oscillometric blood pressure devices, auscultatory method, ambulatory blood pressure monitoring, home blood pressure monitoring, white coat hypertension, masked hypertension, nocturnal blood pressure, cardiovascular risk, children and adolescents, technician training, device calibration
- MeSH terms
- American Heart Association, Blood Pressure, Blood Pressure Determination, Humans, Hypertension, United States, Disease Management, Consensus
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review