CoChat

Comparison of the Efficacy of Morning Versus Evening Administration of Telmisartan in Essential Hypertension

Open access
Hermida, Ramón C., Ayala, Diana E., Fernández, José R., Calvo, Carlos · 2007 · Hypertension
Cited by 134

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Valsartan administration at bedtime as opposed to on wakening improves the sleep time–relative blood pressure decline toward a more dipper pattern without loss in 24-hour efficacy. Yet to be determined is whether this administration time-dependent efficacy is a class-related feature, characteristic of all angiotensin receptor blockers or specific only to valsartan. Terminal half-life is a major difference between angiotensin receptor blockers, being largest (≈24 hours) for telmisartan. This trial investigated the administration time-dependent antihypertensive efficacy of telmisartan. We studied 215 patients with hypertension (114 men and 101 women), 46.4±12.0 years of age, randomly assigned to receive telmisartan (80 mg/d) as a monotherapy either on awakening or at bedtime. Blood pressure was measured for 48 hours before and after 12 weeks of treatment. The significant blood pressure reduction after treatment was similar for both groups. Bedtime administration of telmisartan, however, was more efficient than morning dosing in reducing the nocturnal blood pressure mean. The sleep time–relative blood pressure decline was slightly reduced after telmisartan on awakening but significantly increased with bedtime dosing, thus reducing the prevalence of nondipping from baseline by 76%. Telmisartan administered at bedtime, as opposed to morning dosing, improved the sleep time–relative blood pressure decline toward a more dipper pattern without loss in 24-hour efficacy. Nocturnal BP regulation is significantly better achieved with bedtime dosing of telmisartan. Results from this prospective trial suggest that these beneficial features of bedtime dosing may be class related for angiotensin receptor blockers. These results should be taken into account when prescribing this class of antihypertensive medication for treatment of essential hypertension.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hypertensionaha.107.094235

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 134

Metadata

Authors
Hermida, R. C., Ayala, D. E., Fernández, J. R., & Calvo, C.
Venue
Hypertension
Published
2007-10
Volume
50
Issue
4
Pages
715-722
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2100509895
Cited by
134
References
8
FWCI
6.05
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of the Efficacy of Morning Versus Evening Administration of Telmisartan in Essential Hypertension. https://app.cochat.ai/papers/10.1161/hypertensionaha.107.094235
The paper
Hermida, R. C., Ayala, D. E., Fernández, J. R., & Calvo, C. (2007). Comparison of the Efficacy of Morning Versus Evening Administration of Telmisartan in Essential Hypertension. Hypertension. https://doi.org/10.1161/hypertensionaha.107.094235

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.