The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Call to Action on Use and Reimbursement for Home Blood Pressure Monitoring: Executive Summary: A Joint Scientific Statement From the American Heart Association, American Society of Hypertension, and Preventive Cardiovascular Nurses Association
Open accessAbstract
Home blood pressure monitoring (HBPM) overcomes many of the limitations of traditional office blood pressure (BP) measurement and is both cheaper and easier to perform than ambulatory BP monitoring. Monitors that use the oscillometric method are currently available that are accurate, reliable, easy to use, and relatively inexpensive. An increasing number of patients are using them regularly to check their BP at home, but although this has been endorsed by national and international guidelines, detailed recommendations for their use have been lacking. There is a rapidly growing literature showing that measurements taken by patients at home are often lower than readings taken in the office and closer to the average BP recorded by 24-hour ambulatory monitors, which is the BP that best predicts cardiovascular risk. Because of the larger numbers of readings that can be taken by HBPM than in the office and the elimination of the white-coat effect (the increase of BP during an office visit), home readings are more reproducible than office readings and show better correlations with measures of target organ damage. In addition, prospective studies that have used multiple home readings to express the true BP have found that home BP predicts risk better than office BP (class IIa; level of evidence A). This call-to-action article makes the following recommendations: (1) It is recommended that HBPM should become a routine component of BP measurement in the majority of patients with known or suspected hypertension; (2) Patients should be advised to purchase oscillometric monitors that measure BP on the upper arm with an appropriate cuff size and that have been shown to be accurate according to standard international protocols. They should be shown how to use them by their healthcare providers; (3) Two to 3 readings should be taken while the subject is resting in the seated position, both in the morning and at night, over a period of 1 week. A total of ≥12 readings are recommended for making clinical decisions; (4) HBPM is indicated in patients with newly diagnosed or suspected hypertension, in whom it may distinguish between white-coat and sustained hypertension. If the results are equivocal, ambulatory BP monitoring may help to establish the diagnosis; (5) In patients with prehypertension, HBPM may be useful for detecting masked hypertension; (6) HBPM is recommended for evaluating the response to any type of antihypertensive treatment and may improve adherence; (7) The target HBPM goal for treatment is <135/85 mm Hg or <130/80 mm Hg in high-risk patients; (8) HBPM is useful in the elderly, in whom both BP variability and the white-coat effect are increased; (9) HBPM is of value in patients with diabetes, in whom tight BP control is of paramount importance; (10) Other populations in whom HBPM may be beneficial include pregnant women, children, and patients with kidney disease; and (11) HBPM has the potential to improve the quality of care while reducing costs and should be reimbursed. (Hypertension. 2008;52:1-9.)
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Notwithstanding these results, the 135/85 mmHg threshold, already accepted in 2013 European hypertension guidelines [143] was maintained also in the 2018 ESC/ESH guidelines [1]”
Citations
Cites
Sega, R., Facchetti, R., Bombelli, M., Cesana, G., Corrao, G., Grassi, G., & Mancia, G. (2005) · Circulation · doi:10.1161/01.cir.0000160923.04524.5b · Cited by 1,009
Bobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842
Ohkubo, T., Imai, Y., Tsuji, I., Nagai, K., Kato, J., Kikuchi, N., Nishiyama, A., Aihara, A., Sekino, M., Kikuya, M., et al. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816070-00010 · Cited by 746
Call to Action on Use and Reimbursement for Home Blood Pressure Monitoring
Pickering, T. G., Miller, N. H., Ogedegbe, G. G., Krakoff, L. R., Artinian, N. T., & Goff, D. C. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189010 · Cited by 666
Self-citationFagard, R. H., Broeke, C. V. D., & Cort, P. D. (2005) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001903 · Cited by 321
Oikawa, T., Obara, T., Ohkubo, T., Kikuya, M., Asayama, K., Metoki, H., Komai, R., Murai, K., Hashimoto, J., Totsune, K., et al. (2006) · Journal of Hypertension · doi:10.1097/01.hjh.0000242397.53214.27 · Cited by 82
Cited by
Sorted by citations
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
Self-citationEuropean Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationThe randle cycle revisited: a new head for an old hat.
Hue, L., & Taegtmeyer, H. (2009) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00093.2009 · Cited by 743
Aging and vascular endothelial function in humans
Seals, D. R., Jablonski, K. L., & Donato, A. J. (2011) · Clinical Science · doi:10.1042/cs20100476 · Cited by 725
ACCF/AHA 2011 Expert Consensus Document on Hypertension in the Elderly
Aronow, W. S., Fleg, J. L., Pepine, C. J., Artinian, N. T., Bakris, G. L., Brown, A. S., Ferdinand, K. C., Forciea, M. A., Frishman, W. H., Jaigobin, C. S., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31821daaf6 · Cited by 628
Self-citation
Metadata
- Authors
- Pickering, T. G., Miller, N. H., Ogedegbe, G., Krakoff, L. R., Artinian, N. T., & Goff, D.
- ORCID
- Venue
- Hypertension
- Published
- 2008-07
- Volume
- 52
- Issue
- 1
- Pages
- 1-9
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2562646453
- Cited by
- 294
- References
- 6
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 5 · 2023: 7 · 2022: 12 · 2021: 8 · 2020: 6 · 2019: 16 · 2018: 13 · 2017: 15 · 2016: 20 · 2015: 15 · 2014: 17 · 2013: 27 · 2012: 15
- FWCI
- 26.25
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Hypertension (publishedVersion)
- Funders
- American Heart Association
- Pfizer
- Wayne State University
- Wake Forest University
- Omron Healthcare
- National Heart, Lung, and Blood Institute
- National Institute on Minority Health and Health Disparities
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- home blood pressure monitoring, oscillometric blood pressure monitor, hypertension diagnosis, white coat effect, masked hypertension, ambulatory blood pressure monitoring, antihypertensive treatment response, prehypertension, antihypertensive treatment adherence, reimbursement policy, health technology assessment, cardiovascular risk, target organ damage, antihypertensive drug costs, elderly patients
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review