Validation of a Brachial Cuff-Based Method for Estimating Central Systolic Blood Pressure
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
The prognostic value of central systolic blood pressure has been established recently. At present, its noninvasive assessment is limited by the need of dedicated equipment and trained operators. Moreover, ambulatory and home blood pressure monitoring of central pressures are not feasible. An algorithm enabling conventional automated oscillometric blood pressure monitors to assess central systolic pressure could be of value. We compared central systolic pressure, calculated with a transfer-function like method (ARCSolver algorithm), using waveforms recorded with a regular oscillometric cuff suitable for ambulatory measurements, with simultaneous high-fidelity invasive recordings, and with noninvasive estimations using a validated device, operating with radial tonometry and a generalized transfer function. Both studies revealed a good agreement between the oscillometric cuff-based central systolic pressure and the comparator. In the invasive study, composed of 30 patients, mean difference between oscillometric cuff/ARCSolver-based and invasive central systolic pressures was 3.0 mm Hg (SD: 6.0 mm Hg) with invasive calibration of brachial waveforms and −3.0 mm Hg (SD: 9.5 mm Hg) with noninvasive calibration of brachial waveforms. Results were similar when the reference method (radial tonometry/transfer function) was compared with invasive measurements. In the noninvasive study, composed of 111 patients, mean difference between oscillometric cuff/ARCSolver–derived and radial tonometry/transfer function–derived central systolic pressures was −0.5 mm Hg (SD: 4.7 mm Hg). In conclusion, a novel transfer function-like algorithm, using brachial cuff-based waveform recordings, is suited to provide a realistic estimation of central systolic pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
The CAFE Investigators, CAFE Steering Committee and Writing Committee, Williams, B., Lacy, P. S., Thom, S. M., Cruickshank, K., Stanton, A., Collier, D., Hughes, A. D., Thurston, H., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.595496 · Cited by 1,645
Pauca, A. L., O’Rourke, M. F., & Kon, N. D. (2001) · Hypertension · doi:10.1161/hy1001.096106 · Cited by 1,179
Arterial stiffness, wave reflections, and the risk of coronary artery disease
Weber, T., Auer, J., O’Rourke, M. F., Kvas, E., Lassnig, E., Berent, R., & Eber, B. (2004) · Circulation · doi:10.1161/01.cir.0000105767.94169.e3 · Cited by 1,081
Self-citationRoman, M. J., Devereux, R. B., Kizer, J. R., Lee, E. T., Galloway, J. M., Ali, T., Umans, J. G., & Howard, B. V. (2007) · Hypertension · doi:10.1161/hypertensionaha.107.089078 · Cited by 1,080
Central Pulse Pressure and Mortality in End-Stage Renal Disease
Safar, M. E., Blacher, J., Pannier, B., Guerin, A. P., Marchais, S. J., Guyonvarc’h, P.-M., & London, G. M. (2002) · Hypertension · doi:10.1161/hy0202.098325 · Cited by 805
Central Blood Pressure Measurements and Antihypertensive Therapy: A Consensus Document
Agabiti-Rosei, E., Mancia, G., O’Rourke, M. F., Roman, M. J., Safar, M. E., Smulyan, H., Wang, J.-G., Wilkinson, I. B., Williams, B., & Vlachopoulos, C. (2007) · Hypertension · doi:10.1161/hypertensionaha.107.090068 · Cited by 620
McEniery, C. M., Yasmin, McDonnell, B., Munnery, M., Wallace, S. M., Rowe, C. V., Cockcroft, J. R., & Wilkinson, I. B. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.105445 · Cited by 429
Pini, R., Cavallini, M. C., Palmieri, V., Marchionni, N., Di Bari, M., Devereux, R. B., Masotti, G., & Roman, M. J. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.03.031 · Cited by 386
White, W. B., Berson, A. S., Robbins, C., Jamieson, M. J., Prisant, L. M., Roccella, E., & Sheps, S. G. (1993) · Hypertension · doi:10.1161/01.hyp.21.4.504 · Cited by 385
Wang, K.-L., Cheng, H.-M., Sung, S.-H., Chuang, S.-Y., Li, C.-H., Spurgeon, H. A., Ting, C.-T., Najjar, S. S., Lakatta, E. G., Yin, F. C. P., et al. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.139964 · Cited by 372
A new oscillometric method for pulse wave analysis: comparison with a common tonometric method
Wassertheurer, S., Kropf, J., Weber, T., van der Giet, M., Baulmann, J., Ammer, M., Hametner, B., Mayer, C. C., Eber, B., & Magometschnigg, D. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2010.27 · Cited by 363
Self-citationWang, K.-L., Cheng, H.-M., Chuang, S.-Y., Spurgeon, H. A., Ting, C.-T., Lakatta, E. G., Yin, F. C., Chou, P., & Chen, C.-H. (2009) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283220ea4 · Cited by 362
Does Radial Artery Pressure Accurately Reflect Aortic Pressure?
Pauca, A. L., Wallenhaupt, S. L., Kon, N. D., & Tucker, W. Y. (1992) · Chest · doi:10.1378/chest.102.4.1193 · Cited by 341
Sharman, J. E., Lim, R., Qasem, A. M., Coombes, J. S., Burgess, M. I., Franco, J., Garrahy, P., Wilkinson, I. B., & Marwick, T. H. (2006) · Hypertension · doi:10.1161/01.hyp.0000223013.60612.72 · Cited by 308
Jankowski, P., Kawecka-Jaszcz, K., Czarnecka, D., Brzozowska-Kiszka, M., Styczkiewicz, K., Loster, M., Kloch-Badełek, M., Wiliński, J., Curyło, A. M., & Dudek, D. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.101725 · Cited by 274
Evaluation of the Mobil-O-Graph new generation ABPM device using the ESH criteria
Franssen, P. M. L., & Imholz, B. P. M. (2010) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e328339be38 · Cited by 251
de Luca, N., Asmar, R. G., London, G. M., O'Rourke, M. F., & Safar, M. E. (2004) · Journal of Hypertension · doi:10.1097/01.hjh.0000125448.28861.fc · Cited by 192
Clinical Utility of Aortic Pulses and Pressures Calculated From Applanated Radial-Artery Pulses
Smulyan, H., Siddiqui, D. S., Carlson, R. J., London, G. M., & Safar, M. E. (2003) · Hypertension · doi:10.1161/01.hyp.0000084051.34269.a9 · Cited by 179
Estimation of central aortic pressure by SphygmoCor® requires intra-arterial peripheral pressures
CLOUD, G. C., Rajkumar, C., Kooner, J. S., COOKE, J., & Bulpitt, C. J. (2003) · Clinical Science · doi:10.1042/cs20030012 · Cited by 134
Protogerou, A., Stergiou, G., Vlachopoulos, C., Blacher, J., & Achimastos, A. (2009) · Current Pharmaceutical Design · doi:10.2174/138161209787354186 · Cited by 131
A validation of the Mobil O Graph (version 12) ambulatory blood pressure monitor
Jones, C. R., Taylor, K., Chowienczyk, P., Poston, L., & Shennan, A. H. (2000) · Blood Pressure Monitoring · doi:10.1097/00126097-200008000-00007 · Cited by 129
Papaioannou, T. G., Protogerou, A. D., Stamatelopoulos, K., Vavuranakis, M., & Stefanadis, C. (2009) · Current Pharmaceutical Design · doi:10.2174/138161209787354203 · Cited by 112
Modeling arterial and left ventricular coupling for non-invasive measurements
Wassertheurer, S., Mayer, C. C., & Breitenecker, F. (2008) · Simulation Modelling Practice and Theory · doi:10.1016/j.simpat.2008.04.016 · Cited by 89
Self-citationHickson, S. S., Butlin, M., Mir, F. A., Graggaber, J., Cheriyan, J., Khan, F. Z., Grace, A. A., Yasmin, Y., Cockcroft, J. R., Wilkinson, I. B., et al. (2009) · Journal of Hypertension · doi:10.1097/hjh.0b013e32832e0b58 · Cited by 75
Estimation of central systolic blood pressure using an oscillometric blood pressure monitor
Cheng, H., Wang, K.-L., Chen, Y., Lin, S., Chen, L.-C., Sung, S., Ding, P. Y., Yu, W., Chen, J., & Chen, C.-H. (2010) · Hypertension Research · doi:10.1038/hr.2010.37 · Cited by 63
Westerhof, B. E., Guelen, I., Stok, W. J., Lasance, H. A. J., Ascoop, C. A. P. L., Wesseling, K. H., Westerhof, N., Bos, W. J. W., Stergiopulos, N., & Spaan, J. A. E. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.91052.2008 · Cited by 60
Umana, E., Ahmed, W., Fraley, M. A., & Alpert, M. A. (2006) · Angiology · doi:10.1177/000331970605700106 · Cited by 56
A Preliminary Evaluation of the Mean Arterial Pressure as Measured by Cuff Oscillometry
Smulyan, H., Sheehe, P. R., & Safar, M. E. (2008) · American Journal of Hypertension · doi:10.1038/ajh.2007.45 · Cited by 49
Fernández‐González, R., Gómez-Pajuelo, C., Gabriel, R., de la Figuera, M., Moreno, E., & Res, O. T. V.-F. (2000) · Blood Pressure Monitoring · doi:10.1097/00126097-200002000-00005 · Cited by 9
Studinger, P., Ungi, I., Lénárd, Z., Mersich, B., Rudas, L., & Kollai, M. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282fd125b · Cited by 7
Cited by
Townsend, R. R., Wilkinson, I. B., Schiffrin, E. L., Avolio, A. P., Chirinos, J. A., Cockcroft, J. R., Heffernan, K. S., Lakatta, E. G., McEniery, C. M., Mitchell, G. F., et al. (2015) · Hypertension · doi:10.1161/hyp.0000000000000033 · Cited by 1,473
Self-citationOlsen, M. H., Angell, S. Y., Asma, S., Boutouyrie, P., Burger, D., Chirinos, J. A., Damasceno, A., Delles, C., Gimenez-Roqueplo, A.-P., Hering, D., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31134-5 · Cited by 939
Vlachopoulos, C., Xaplanteris, P., Aboyans, V., Brodmann, M., Cífková, R., Cosentino, F., De Carlo, M., Gallino, A., Landmesser, U., Laurent, S., et al. (2015) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2015.05.007 · Cited by 716
Self-citationCentral blood pressure: current evidence and clinical importance
McEniery, C. M., Cockcroft, J. R., Roman, M. J., Franklin, S. S., & Wilkinson, I. B. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht565 · Cited by 678
Herbert, A., Cruickshank, J. K., Laurent, S., & Boutouyrie, P. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu293 · Cited by 290
Metadata
- Authors
- Weber, T., Wassertheurer, S., Rammer, M., Maurer, E., Hametner, B., Mayer, C. C., Kropf, J., & Eber, B.
- Venue
- Hypertension
- Published
- 2011-11
- Volume
- 58
- Issue
- 5
- Pages
- 825-832
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2140653455
- Cited by
- 461
- References
- 32
- FWCI
- 14.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.