Thresholds for Diagnosing Hypertension Based on Automated Office Blood Pressure Measurements and Cardiovascular Risk
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The risk of cardiovascular events in relation to blood pressure is largely based on readings taken with a mercury sphygmomanometer in populations which differ from those of today in terms of hypertension severity and drug therapy. Given replacement of the mercury sphygmomanometer with electronic devices, we sought to determine the blood pressure threshold for a significant increase in cardiovascular risk using a fully automated device, which takes multiple readings with the subject resting quietly alone. Participants were 3627 community-dwelling residents aged >65 years untreated for hypertension. Automated office blood pressure readings were obtained in a community pharmacy with subjects seated and undisturbed. This method for recording blood pressure produces similar readings in different settings, including a pharmacy and family doctor’s office providing the above procedures are followed. Subjects were followed for a mean (SD) of 4.9 (1.0) years for fatal and nonfatal cardiovascular events. Adjusted hazard ratios (95% confidence intervals) were computed for 10 mm Hg increments in blood pressure (mm Hg) using Cox proportional hazards regression and the blood pressure category with the lowest event rate as the reference category. A total of 271 subjects experienced a cardiovascular event. There was a significant ( P =0.02) increase in the hazard ratio of 1.66 (1.09, 2.54) at a systolic blood pressure of 135 to 144 and 1.72 (1.21, 2.45; P =0.003) at a diastolic blood pressure of 80 to 89. A significant ( P =0.03) increase in hazard ratio of 1.73 (1.04, 2.86) occurred with a pulse pressure of 80 to 89. These findings are consistent with a threshold of 135/85 for diagnosing hypertension in older subjects using automated office blood pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationParati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Measurement of Blood Pressure in the Office: Recognizing the Problem and Proposing the Solution
Myers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., & Kaczorowski, J. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.141879 · Cited by 260 · cited 1×
“Based on these comparative AOBP data, a cut-point of 135/85 mm Hg has been proposed when using AOBP to diagnose hypertension.(8) Unlike conventional office BP, AOBP readings do not seem to be affected by the setting in which the BP is recorded, providing the above procedures for AOBP are followed.”
MethodSelf-citation
Cited by
Mancia, G., Kreutz, R., Brunström, M., Burnier, M., Grassi, G., Januszewicz, A., Muiesan, M. L., Tsioufis, K., Agabiti-Rosei, E., Algharably, E. A. E., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003480 · Cited by 3,473
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
“It may be possible to use an ankle-based BP in the supine position, recognizing that the ankle SBP is usually higher than a simultaneous measurement in the brachial artery as a result of SBP amplification, generally on the order of ≈20 mm Hg.293 In special circumstances when the carotid artery pressure is known or tho…”
BackgroundSelf-citationCarey, R. M., Calhoun, D. A., Bakris, G. L., Brook, R. D., Daugherty, S. L., Dennison-Himmelfarb, C. R., Egan, B. M., Flack, J. M., Gidding, S. S., Judd, E., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000084 · Cited by 1,153
Olsen, M. H., Angell, S. Y., Asma, S., Boutouyrie, P., Burger, D., Chirinos, J. A., Damasceno, A., Delles, C., Gimenez-Roqueplo, A.-P., Hering, D., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31134-5 · Cited by 939
Leung, A. A., Nerenberg, K., Daskalopoulou, S. S., McBrien, K., Zarnke, K. B., Dasgupta, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., et al. (2016) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2016.02.066 · Cited by 461
Self-citation
Metadata
- Authors
- Myers, M. G., Kaczorowski, J., Paterson, J. M., Dolovich, L., & Tu, K.
- Venue
- Hypertension
- Published
- 2015-09
- Volume
- 66
- Issue
- 3
- Pages
- 489-495
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2149009772
- Cited by
- 106
- References
- 4
- FWCI
- 12.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thresholds for Diagnosing Hypertension Based on Automated Office Blood Pressure Measurements and Cardiovascular Risk. https://app.cochat.ai/papers/10.1161/hypertensionaha.115.05782
- The paper
- Myers, M. G., Kaczorowski, J., Paterson, J. M., Dolovich, L., & Tu, K. (2015). Thresholds for Diagnosing Hypertension Based on Automated Office Blood Pressure Measurements and Cardiovascular Risk. Hypertension. https://doi.org/10.1161/hypertensionaha.115.05782
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.