Cardiovascular Risk in Hypertension in Relation to Achieved Blood Pressure Using Automated Office Blood Pressure Measurement
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The SPRINT (Systolic Blood Pressure Intervention Trial) reported that some older, higher risk patients might benefit from a target systolic blood pressure (BP) of <120 versus <140 mm Hg. However, it is not yet known how the BP target and measurement methods used in SPRINT relate to cardiovascular outcomes in real-world practice. SPRINT used the automated office BP technique, which requires the patient to be resting quietly and alone, with multiple readings being recorded automatically using an electronic oscillometric sphygmomanometer. We studied the relationship between achieved automated office BP at baseline and cardiovascular events in 6183 community-dwelling residents of Ontario aged ≥66 years who were receiving antihypertensive therapy and followed for a mean of 4.6 years. Adjusted hazard ratios (95% confidence intervals) were computed for 10 mm Hg increments in achieved automated office BP at baseline using Cox proportional hazards regression and the BP category with the lowest event rate as the reference category. Based on 904 fatal and nonfatal cardiovascular events, the nadir of cardiovascular events was at the systolic pressure category of 110 to 119 mm Hg, which was lower than the next highest category of 120 to 129 mm Hg (hazard ratio 1.30 [1.01, 1.66]). The hazard ratio for diastolic pressure was relatively unchanged above 60 mm Hg. Pulse pressure exhibited an increase in hazard ratio (1.33 [1.02, 1.72]) at ≥80 mm Hg. These results using automated office BP measurement in a usual treatment setting extend the finding in SPRINT of an optimum target systolic BP of <120 mm Hg to routine clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
James, P. A., Oparil, S., Carter, B. L., Cushman, W. C., Dennison-Himmelfarb, C., Handler, J., Lackland, D. T., LeFevre, M. L., MacKenzie, T. D., Ogedegbe, O., et al. (2014) · JAMA · doi:10.1001/jama.2013.284427 · Cited by 7,950
A Randomized Trial of Intensive versus Standard Blood-Pressure Control
The SPRINT Research Group (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1511939 · Cited by 6,325
Effects of intensive blood-pressure control in type 2 diabetes mellitus
(2010) · New England Journal of Medicine · doi:10.1056/nejmoa1001286 · Cited by 3,598
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationParati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Measurement of Blood Pressure in the Office: Recognizing the Problem and Proposing the Solution
Myers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., & Kaczorowski, J. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.141879 · Cited by 260
Self-citationDefining Thresholds for Home Blood Pressure Monitoring in Octogenarians
Aparicio, L. S., Thijs, L., Boggia, J., Jacobs, L., Barochiner, J., Odili, A. N., Alfie, J., Asayama, K., Cuffaro, P. E., Nomura, K., et al. (2015) · Hypertension · doi:10.1161/hypertensionaha.115.05800 · Cited by 45
Cited by
2018 ESC/ESH Guidelines for the management of arterial hypertension
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy339 · Cited by 10,286
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001940 · Cited by 2,885
The Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2019)
Umemura, S., Arima, H., Arima, S., Asayama, K., Dohi, Y., Hirooka, Y., Horio, T., Hoshide, S., Ikeda, S., Ishimitsu, T., et al. (2019) · Hypertension Research · doi:10.1038/s41440-019-0284-9 · Cited by 1,880
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
“110 to 119 mm Hg has been associated with the lowest CVD event rate.(61)”
BackgroundSelf-citationOffice blood pressure measurement in the 21st century
Myers, M. G., Asmar, R., & Staessen, J. A. (2018) · The Journal of Clinical Hypertension · doi:10.1111/jch.13276 · Cited by 34
Self-citation
Metadata
- Authors
- Myers, M. G., Kaczorowski, J., Dolovich, L., Tu, K., & Paterson, J. M.
- Venue
- Hypertension
- Published
- 2016-10
- Volume
- 68
- Issue
- 4
- Pages
- 866-872
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2511486388
- Cited by
- 60
- References
- 8
- FWCI
- 8.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiovascular Risk in Hypertension in Relation to Achieved Blood Pressure Using Automated Office Blood Pressure Measurement. https://app.cochat.ai/papers/10.1161/hypertensionaha.116.07721
- The paper
- Myers, M. G., Kaczorowski, J., Dolovich, L., Tu, K., & Paterson, J. M. (2016). Cardiovascular Risk in Hypertension in Relation to Achieved Blood Pressure Using Automated Office Blood Pressure Measurement. Hypertension. https://doi.org/10.1161/hypertensionaha.116.07721
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.