The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Optimal Tmax Threshold for Predicting Penumbral Tissue in Acute Stroke
Open accessAbstract
Background and Purpose— We sought to assess whether the volume of the ischemic penumbra can be estimated more accurately by altering the threshold selected for defining perfusion-weighting imaging (PWI) lesions. Methods— DEFUSE is a multicenter study in which consecutive acute stroke patients were treated with intravenous tissue-type plasminogen activator 3 to 6 hours after stroke onset. Magnetic resonance imaging scans were obtained before, 3 to 6 hours after, and 30 days after treatment. Baseline and posttreatment PWI volumes were defined according to increasing Tmax delay thresholds (>2, >4, >6, and >8 seconds). Penumbra salvage was defined as the difference between the baseline PWI lesion and the final infarct volume (30-day fluid-attenuated inversion recovery sequence). We hypothesized that the optimal PWI threshold would provide the strongest correlations between penumbra salvage volumes and various clinical and imaging-based outcomes. Results— Thirty-three patients met the inclusion criteria. The correlation between infarct growth and penumbra salvage volume was significantly better for PWI lesions defined by Tmax >6 seconds versus Tmax >2 seconds, as was the difference in median penumbra salvage volume in patients with a favorable versus an unfavorable clinical response. Among patients who did not experience early reperfusion, the Tmax >4 seconds threshold provided a more accurate prediction of final infarct volume than the >2 seconds threshold. Conclusions— Defining PWI lesions based on a stricter Tmax threshold than the standard >2 seconds delay appears to provide more a reliable estimate of the volume of the ischemic penumbra in stroke patients imaged between 3 and 6 hours after symptom onset. A threshold between 4 and 6 seconds appears optimal for early identification of critically hypoperfused tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thresholds in cerebral ischemia - the ischemic penumbra.
Astrup, J., Siesjö, B. K., & Symon, L. (1981) · Stroke · doi:10.1161/01.str.12.6.723 · Cited by 2,820
Viability thresholds and the penumbra of focal ischemia
Hossmann, K. (1994) · Annals of Neurology · doi:10.1002/ana.410360404 · Cited by 1,370
Albers, G. W., Thijs, V. N., Wechsler, L., Kemp, S., Schlaug, G., Skalabrin, E., Bammer, R., Kakuda, W., Lansberg, M. G., Shuaib, A., et al. (2006) · Annals of Neurology · doi:10.1002/ana.20976 · Cited by 1,268
Self-citationDavis, S. M., Donnan, G. A., Parsons, M. W., Levi, C., Butcher, K. S., Peeters, A., Barber, P. A., Bladin, C., De Silva, D. A., Byrnes, G., et al. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70044-9 · Cited by 1,052
(2024) · American Journal of Neuroradiology · doi:10.3174/ajnr.45-12.s8 · Cited by 890
Spontaneous neurological recovery after stroke and the fate of the ischemic penumbra
Furlan, M., Marchal, G., Derlon, J., Baron, J., & Viader, F. (1996) · Annals of Neurology · doi:10.1002/ana.410400213 · Cited by 519
Kidwell, C. S., Alger, J. R., & Saver, J. L. (2003) · Stroke · doi:10.1161/01.str.0000097608.38779.cc · Cited by 473
Calamante, F., Gadian, D. G., & Connelly, A. (2002) · Stroke · doi:10.1161/01.str.0000014208.05597.33 · Cited by 283
Shih, L. C., Saver, J. L., Alger, J. R., Starkman, S., Leary, M. C., Vinuela, F., Duckwiler, G., Gobin, Y. P., Jahan, R., Villablanca, J. P., et al. (2003) · Stroke · doi:10.1161/01.str.0000072998.70087.e9 · Cited by 195
Optimal Definition for PWI/DWI Mismatch in Acute Ischemic Stroke Patients
Kakuda, W., Lansberg, M. G., Thijs, V., Kemp, S. M., Bammer, R., Wechsler, L. R., Moseley, M. E., Parks, M. P., Albers, G. W., & on behalf of The DEFUSE Investigators (2008) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600604 · Cited by 157
Self-citation
Cited by
Real‐time diffusion‐perfusion mismatch analysis in acute stroke
Straka, M., Albers, G. W., & Bammer, R. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22338 · Cited by 401
Self-citation
Metadata
- Authors
- Olivot, J.-M., Mlynash, M., Thijs, V. N., Kemp, S., Lansberg, M. G., Wechsler, L., Bammer, R., Marks, M. P., & Albers, G. W.
- Venue
- Stroke
- Published
- 2009-02
- Volume
- 40
- Issue
- 2
- Pages
- 469-475
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2156896333
- Cited by
- 401
- References
- 15
- FWCI
- 12.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal Tmax Threshold for Predicting Penumbral Tissue in Acute Stroke. https://app.cochat.ai/papers/10.1161/strokeaha.108.526954
- The paper
- Olivot, J.-M., Mlynash, M., Thijs, V. N., Kemp, S., Lansberg, M. G., Wechsler, L., Bammer, R., Marks, M. P., & Albers, G. W. (2009). Optimal Tmax Threshold for Predicting Penumbral Tissue in Acute Stroke. Stroke. https://doi.org/10.1161/strokeaha.108.526954
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.