Insertable Cardiac Event Recorder in Detection of Atrial Fibrillation After Cryptogenic Stroke: An Audit Report
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background and Purpose—: Atrial fibrillation (AF) is the most frequent risk factor in ischemic stroke but often remains undetected. We analyzed the value of insertable cardiac event recorder in detection of AF in a 1-year cohort of patients with cryptogenic ischemic stroke. Methods—: All patients with cryptogenic stroke and eligibility for oral anticoagulation were offered the insertion of a cardiac event recorder. Regular follow-up for 1 year recorded the incidence of AF. Results—: Of the 393 patients with ischemic stroke, 65 (16.5%) had a cryptogenic stroke, and in 22 eligible patients, an event recorder was inserted. After 1 year, in 6 of 22 patients (27.3%), AF was detected. Conclusions—: These preliminary data show that insertion of cardiac event recorder was eligible in approximately one third of patients with cryptogenic stroke and detected in approximately one quarter of these patients new AF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hindricks, G., Pokushalov, E., Urban, L., Taborsky, M., Kuck, K.-H., Lebedev, D., Rieger, G., & Pürerfellner, H. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.877852 · Cited by 422
Excessive Supraventricular Ectopic Activity and Increased Risk of Atrial Fibrillation and Stroke
Binici, Z., Intzilakis, T., Nielsen, O. W., Køber, L., & Sajadieh, A. (2010) · Circulation · doi:10.1161/circulationaha.109.874982 · Cited by 379
Rizos, T., Güntner, J., Jenetzky, E., Marquardt, L., Reichardt, C., Becker, R., Reinhardt, R., Hepp, T., Kirchhof, P., Aleynichenko, E., et al. (2012) · Stroke · doi:10.1161/strokeaha.112.654954 · Cited by 218 · cited 1×
“ECG monitoring, which has recently been shown to increase the detection rate of paroxysmal AF in patients with stroke.(11) Last, by analyzing only AF duration ≥6 minutes shorter,”
Cited by
Cryptogenic stroke and underlying atrial fibrillation
Sanna, T., Diener, H.-C., Passman, R. S., Di Lazzaro, V., Bernstein, R. A., Morillo, C. A., Rymer, M. M., Thijs, V., Rogers, T., Beckers, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313600 · Cited by 2,161
Embolic strokes of undetermined source: the case for a new clinical construct
Hart, R. G., Diener, H.-C., Coutts, S. B., Easton, J. D., Granger, C. B., O'Donnell, M. J., Sacco, R. L., & Connolly, S. J. (2014) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70310-7 · Cited by 1,681
Sposato, L. A., Cipriano, L. E., Saposnik, G., Vargas, E. R., Riccio, P. M., & Hachinski, V. (2015) · The Lancet Neurology · doi:10.1016/s1474-4422(15)70027-x · Cited by 694
Gorenek, B., Bax, J., Boriani, G., Chen, S.-A., Dagres, N., Glotzer, T. V., Healey, J. S., Israel, C. W., Kudaiberdieva, G., Levin, L.-Å., et al. (2017) · EP Europace · doi:10.1093/europace/eux163 · Cited by 247
“2% 435 All patients were <75 years of age; EP testing of no value Etgen et al.(81) (2013) 22 6 min 27.”
BackgroundGrond, M., Jauss, M., Hamann, G., Stark, E., Veltkamp, R., Nabavi, D., Horn, M., Weimar, C., Köhrmann, M., Wachter, R., et al. (2013) · Stroke · doi:10.1161/strokeaha.113.001884 · Cited by 229
“With ischemic lesion in CT/MRI 52 (16) 5 (55) 0.”
BackgroundSilent atrial fibrillation: epidemiology, diagnosis, and clinical impact
Dilaveris, P. E., & Kennedy, H. L. (2017) · Clinical Cardiology · doi:10.1002/clc.22667 · Cited by 198
Brachmann, J., Morillo, C. A., Sanna, T., Di Lazzaro, V., Diener, H.-C., Bernstein, R. A., Rymer, M., Ziegler, P. D., Liu, S., & Passman, R. S. (2016) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.115.003333 · Cited by 182
“7%).(20,22,31) The reasons for having lower detection rates at shorter follow-up periods compared with others are likely related to the comprehensive assessment required before the diagnosis of CS, the duration of AF used to define episodes, and differences in baseline characteristics associated with AF, including you…”
BackgroundSanders, P., Pürerfellner, H., Pokushalov, E., Sarkar, S., Di Bacco, M., Maus, B., & Dekker, L. R. C. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.03.005 · Cited by 162
“Insertable cardiac monitors (ICMs) with dedicated AF algorithms have been introduced into clinical practice for the diagnosis and monitoring of AF in various clinical applications, such as recurrent AF diagnosis after surgical(12) or catheter AF ablation,(9,13,14) and cryptogenic stroke.(15,16) ICMs have been shown to…”
MethodThe Reveal LINQ insertable cardiac monitor
Tomson, T. T., & Passman, R. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.953059 · Cited by 72
Metadata
- Authors
- Etgen, T., Hochreiter, M., Mundel, M., & Freudenberger, T.
- Venue
- Stroke
- Published
- 2013-07
- Volume
- 44
- Issue
- 7
- Pages
- 2007-2009
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2055359003
- Cited by
- 100
- References
- 3
- FWCI
- 11.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.