Atrial Premature Beats Predict Atrial Fibrillation in Cryptogenic Stroke: Results From the EMBRACE Trial
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Background and Purpose—: Many ischemic strokes or transient ischemic attacks are labeled cryptogenic but may have undetected atrial fibrillation (AF). We sought to identify those most likely to have subclinical AF. Methods—: We prospectively studied patients with cryptogenic stroke or transient ischemic attack aged ≥55 years in sinus rhythm, without known AF, enrolled in the intervention arm of the 30 Day Event Monitoring Belt for Recording Atrial Fibrillation After a Cerebral Ischemic Event (EMBRACE) trial. Participants underwent baseline 24-hour Holter ECG poststroke; if AF was not detected, they were randomly assigned to 30-day ECG monitoring with an AF auto-detect external loop recorder. Multivariable logistic regression assessed the association between baseline variables (Holter-detected atrial premature beats [APBs], runs of atrial tachycardia, age, and left atrial enlargement) and subsequent AF detection. Results—: Among 237 participants, the median baseline Holter APB count/24 h was 629 (interquartile range, 142–1973) among those who subsequently had AF detected versus 45 (interquartile range, 14–250) in those without AF ( P <0.001). APB count was the only significant predictor of AF detection by 30-day ECG ( P <0.0001), and at 90 days ( P =0.0017) and 2 years ( P =0.0027). Compared with the 16% overall 90-day AF detection rate, the probability of AF increased from <9% among patients with <100 APBs/24 h to 9% to 24% in those with 100 to 499 APBs/24 h, 25% to 37% with 500 to 999 APBs/24 h, 37% to 40% with 1000 to 1499 APBs/24 h, and 40% beyond 1500 APBs/24 h. Conclusions—: Among older cryptogenic stroke or transient ischemic attack patients, the number of APBs on a routine 24-hour Holter ECG was a strong dose-dependent independent predictor of prevalent subclinical AF. Those with frequent APBs have a high probability of AF and represent ideal candidates for prolonged ECG monitoring for AF detection. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT00846924.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kernan, W. N., Ovbiagele, B., Black, H. R., Bravata, D. M., Chimowitz, M. I., Ezekowitz, M. D., Fang, M. C., Fisher, M., Furie, K. L., Heck, D. V., et al. (2014) · Stroke · doi:10.1161/str.0000000000000024 · Cited by 5,170 · cited 2×
“Longer duration ECG monitoring (eg, for 7 days, 30 days, or up to 3 years) significantly improves AF detection and treatment compared with standard care and is being recommended by new practice guidelines.(2,7,8) However, it is unclear which subgroups benefit most from additional monitoring, how much monitoring should…”
BackgroundCryptogenic stroke and underlying atrial fibrillation
Sanna, T., Diener, H.-C., Passman, R. S., Di Lazzaro, V., Bernstein, R. A., Morillo, C. A., Rymer, M. M., Thijs, V., Rogers, T., Beckers, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313600 · Cited by 2,161
Subclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100
Atrial fibrillation in patients with cryptogenic stroke
Gladstone, D. J., Spring, M., Dorian, P., Panzov, V., Thorpe, K. E., Hall, J., Vaid, H., O'Donnell, M., Laupacis, A., Côté, R., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1311376 · Cited by 1,276
Self-citationGlotzer, T. V., Hellkamp, A. S., Zimmerman, J., Sweeney, M. O., Yee, R., Marinchak, R., Cook, J., Paraschos, A., Love, J., Radoslovich, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000057981.70380.45 · Cited by 750 · cited 1×
“Two cohort studies in pacemaker patients demonstrated that subclinical AF as brief as 5 or 6 minutes in duration is associated with an increased risk of stroke.(24,25) However, many strokes in the pacemaker studies occurred without the development of longer-lasting AF episodes or lacked a temporal association with the…”
Temporal relationship between subclinical atrial fibrillation and embolic events
Brambatti, M., Connolly, S. J., Gold, M. R., Morillo, C. A., Capucci, A., Muto, C., Lau, C. P., Van Gelder, I. C., Hohnloser, S. H., Carlson, M., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.007825 · Cited by 676
Tsang, T. S. M., Barnes, M. E., Bailey, K. R., Leibson, C. L., Montgomery, S. C., Takemoto, Y., Diamond, P. M., Marra, M. A., Gersh, B. J., Wiebers, D. O., et al. (2001) · Mayo Clinic Proceedings · doi:10.4065/76.5.467 · Cited by 631
Excessive Supraventricular Ectopic Activity and Increased Risk of Atrial Fibrillation and Stroke
Binici, Z., Intzilakis, T., Nielsen, O. W., Køber, L., & Sajadieh, A. (2010) · Circulation · doi:10.1161/circulationaha.109.874982 · Cited by 379 · cited 2×
“In our study, we found that nearly 50% patients with cryptogenic stroke had an APB frequency >720/24 h, which is potentially clinically important based on the above literature.(15) However, as the aforementioned studies did not use any sensitive long-term monitoring for AF, it is unclear whether the increased stroke o…”
Kishore, A., Vail, A., Majid, A., Dawson, J., Lees, K. R., Tyrrell, P. J., & Smith, C. J. (2014) · Stroke · doi:10.1161/strokeaha.113.003433 · Cited by 374
Daoud, E. G., Glotzer, T. V., Wyse, D. G., Ezekowitz, M. D., Hilker, C., Koehler, J., & Ziegler, P. D. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.04.022 · Cited by 326 · cited 1×
“However, many strokes in the pacemaker studies occurred without the development of longer-lasting AF episodes or lacked a temporal association with the AF episodes.(26,27) Such observations suggest that brief atrial arrhythmias or frequent APBs may be a stroke risk marker independent of causal mechanisms, such as the…”
Background
Cited by
Noseworthy, P. A., Kaufman, E. S., Chen, L. Y., Chung, M. K., Elkind, M. S. V., Joglar, J. A., Leal, M. A., McCabe, P. J., Pokorney, S. D., Yao, X., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000740 · Cited by 171
Predictors for atrial fibrillation detection after cryptogenic stroke: Results from CRYSTAL AF
Thijs, V. N., Brachmann, J., Morillo, C. A., Passman, R. S., Sanna, T., Bernstein, R. A., Diener, H.-C., Di Lazzaro, V., Rymer, M. M., Hogge, L., et al. (2016) · Neurology · doi:10.1212/wnl.0000000000002282 · Cited by 170
Silent atrial fibrillation: Definition, clarification, and unanswered issues
Kennedy, H. L. (2015) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12307 · Cited by 32
Single‑lead patch recording systems: The expanding role for long-term ECG recording systems
Ben-Dov, N., Gladstone, D. J., Micieli, A., Crystal, E., & Newman, D. (2019) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2019.03.004 · Cited by 3
Self-citation
Metadata
- Authors
- Gladstone, D. J., Dorian, P., Spring, M., Panzov, V., Mamdani, M., Healey, J. S., Thorpe, K. E., EMBRACE Steering Committee or Operations Committee, Aviv, R., Boyle, K., Blakely, J., Cote, R., Hall, J., Kapral, M. K., Kozlowski, N., Laupacis, A., O’Donnell, M., Sabihuddin, K., Sharma, M., Shuaib, A., Vaid, H., ECG Adjudication Committee, Pinter, A., Sites, E. P., Abootalebi, S., Chan, R., Crann, S., Fleming, L., Frank, C., Hachinski, V., Hesser, K., Kumar, B. S., Soros, P., Wright, M., Basile, V., Boyle, K., Hopyan, J., Rajmohan, Y., Swartz, R., Vaid, H., Valencia, G., Ween, J., Aram, H., Barber, P. A., Coutts, S., Demchuk, A. M., Fischer, K., Hill, M. D., Klein, G., Kenney, C., Menon, B., McClelland, M., Russell, A., Ryckborst, K., Stys, P., Smith, E. E., Watson, T. W., Chacko, S., Sahlas, D., Sancan, J., Côté, R., Durcan, L., Ehrensperger, E., Minuk, J., Wein, T., Wadup, L., Asdaghi, N., Beckman, J., Esplana, N., Masigan, P., Murphy, C., Tang, E., Teal, P., Villaluna, K., Woolfenden, A., Yip, S., Bussière, M., Dowlatshahi, D., Sharma, M., Stotts, G., Robert, S., Ford, K., Hackam, D., Miners, L., Mabb, T., Spence, J. D., Buck, B., Griffin-Stead, T., Jassal, R., Siddiqui, M., Hache, A., Lessard, C., Lebel, F., Mackey, A., Verreault, S., Astorga, C., Casaubon, L., del Campo, M., Jaigobin, C., Kalman, L., Silver, F., Atkins, L., Coles, K., Penn, A., Sargent, R., Walter, C., Gable, Y., Kadribasic, N., Schwindt, B., Shuaib, A., Kostyrko, P., Selchen, D., Saposnik, G., Christie, P., Jin, A., Hicklin, D., Howse, D., Edwards, E., Jaspers, S., Sher, F., Stoger, S., Crisp, D., Dhanani, A., John, V., Levitan, M., Mehdiratta, M., & Wong, D.
- Venue
- Stroke
- Published
- 2015-04
- Volume
- 46
- Issue
- 4
- Pages
- 936-941
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W1987466684
- Cited by
- 205
- References
- 10
- FWCI
- 14.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Atrial Premature Beats Predict Atrial Fibrillation in Cryptogenic Stroke: Results From the EMBRACE Trial. https://app.cochat.ai/papers/10.1161/strokeaha.115.008714
- The paper
- Gladstone, D. J., Dorian, P., Spring, M., Panzov, V., Mamdani, M., Healey, J. S., Thorpe, K. E., EMBRACE Steering Committee or Operations Committee, Aviv, R., Boyle, K., Blakely, J., Cote, R., Hall, J., Kapral, M. K., Kozlowski, N., Laupacis, A., O’Donnell, M., Sabihuddin, K., Sharma, M., . . . Wong, D. (2015). Atrial Premature Beats Predict Atrial Fibrillation in Cryptogenic Stroke: Results From the EMBRACE Trial. Stroke. https://doi.org/10.1161/strokeaha.115.008714
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.