Cited by 99Clinical Laboratory Practices and Quality ControlBacterial Identification and Susceptibility TestingBlood transfusion and management

Croatian Society of Medical Biochemistry and Laboratory Medicine: national recommendations for venous blood sampling

Open access
Nikolac, Nora, Šupak Smolčić, Vesna, Šimundić, Ana-Maria, Ćelap, Ivana·2013·Biochemia Medica

Abstract

Phlebotomy is one of the most complex medical procedures in the diagnosis, management and treatment of patients in healthcare. Since laboratory test results are the basis for a large proportion (60-80%) of medical decisions, any error in the phlebotomy process could have serious consequences. In order to minimize the possibility of errors, phlebotomy procedures should be standardised, well-documented and written instructions should be available at every workstation. Croatia is one of the few European countries that have national guidelines for phlebotomy, besides the universally used CLSI (Clinical Laboratory Standards Institute) H3-A6 Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture; approved Standard-Sixth Edition (CLSI, 2007) and WHO (World Health Organization) guidelines on drawing blood: best practices in phlebotomy (WHO, 2010). However, the growing body of evidence in importance of preanalytical phase management resulted in a need for evidence based revision and expansion of existing recommendations. The Croatian Society for Medical Biochemistry and Laboratory Medicine, Working Group for the Preanalytical Phase issued this recommendation. This document is based on the CLSI guideline H3-A6, with significant differences and additional information.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.11613/bm.2013.031

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Other potential factors such as regular or recent physical activity, food intake, and intake of drugs, over-the-counter medicines, food supplements, and herbal preparations are known to affect the concentration of certain analytes.

    “There are other potential factors such as regular or/and recent physical activity, food intake and intake of drugs, over-the-counter medicines, food supplements and herbal preparations, etc. which are known to affect the concentration of certain analytes and it should be verified whether the patient has followed necessary instructions before blood sampling [23], [24], [25].”

    From Joint EFLM-COLABIOCLI Recommendation for venous blood sampling (2018) · cites this paper as [25]

    The Procedure section, “Verifying patient preparation for venipuncture” (page not provided), says diet restrictions and therapy protocols can matter for test results and recommends checking patient preparation before blood sampling. It does not specifically address regular or recent physical activity, over-the-counter medicines, food supplements, or herbal preparations as factors affecting analyte concentrations. (LLM, conf=0.83)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 40

  1. [1]Plebani M Errors in clinical laboratories or errors in laboratory medicine? Clin Chem Lab Med 2006 44 750 9 http://dx.doi.org/10.1515/CCLM.2006.123 16729864 · DOI
  2. [2]Lippi G Becan-McBride K Behúlová D Bowen RAR Church S Delanghe JR Preanalytical quality improvement: in quality we trust Clin Chem Lab Med 2013 51 229 41 http://dx.doi.org/10.1515/cclm-2012-0597 23072858 · DOI
  3. [3]Simundic AM Nikolac N Vukasovic I Vrkic N The prevalence of preanalytical errors in Croatian ISO 15189 accredited laboratory Clin Chem Lab Med 2010 48 1009 14 http://dx.doi.org/10.1515/cclm.2010.221 20441481 · DOI
  4. [4]Lippi G Salvagno GL Montagnana M Franchini M Guidi GC Phlebotomy issues and quality improvement in results of laboratory testing Clin Lab 2006 52 217 30 16812947
  5. [5]Lavery I Ingram P Venepuncture: best practice Nurs Stand 2005 19 55 65 http://dx.doi.org/10.7748/ns2005.08.19.49.55.c3936 16134421 · DOI
  6. [6]Forsman RW Why is the laboratory an afterthought for managed care organizations? Clin Chem 1996 42 813 6 8653920
  7. [7]Katayev A Balciza C Seccombe DW Establishing reference intervals for clinical laboratory test results: is there a better way? Am J Clin Pathol 2010 133 180 6 http://dx.doi.org/10.1309/AJCPN5BMTSF1CDYP 20093226 · DOI
  8. [8]Green SF The cost of poor blood specimen quality and errors in preanalytical processes Clin Biochem 2013 10.1016/j.clinbiochem.2013.06.001 [Epub ahead of print] http://dx.doi.org/10.1016/j.clinbiochem.2013.06.001. 23769816 · DOI
  9. [9]Simundic AM Cornes M Grankvist K Lippi G Nybo M Kovalevskaya S Survey of national guidelines, education and training on phlebotomy in 28 European countries: an original report by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) working group for the preanalytical phase (WG-PA) Clin Chem Lab Med 2013 51 1 9 http://dx.doi.org/10.1515/cclm-2013-0283 23729577 · DOI · Paper page
  10. [10]Clinical Laboratory Standards Institute Procedures for the Collection of Diagnostic Blood Specimens by. Venipuncture; Approved Standard—Sixth Edition. CLSI document H3-A6 Clinical Laboratory Standards Institute Wayne, Pennsylvania, USA 2007
  11. [16]Lipley N Staff require training in phlebotomy to ensure accurate blood test results Emerg Nurse 2011 19 9 http://dx.doi.org/10.7748/en2011.11.19.7.9.p6835 22167920 · DOI
  12. [17]Simundic AM Topic E Cvoriscec D Cepelak I Clinical chemistry and laboratory medicine in Croatia: regulation of the profession Biochem Med 2011 21 15 21 http://dx.doi.org/10.11613/BM.2011.005 22141201 · DOI
  13. [18]Kalenić S Budimir A Bosnjak Z Acketa L Belina D Benko I [Smjernice za higijenu ruku u zdravstvenim ustanovama]. (in Croatian) Lijec Vjesn 2011 133 155 70 21888080
  14. [19]International Organization for Standardization ISO 15189:2012 Medical laboratories -- Requirements for quality and competence Medical laboratories -- Requirements for quality and competence 2012 12617164
  15. [20]Henneman PL Fisher DL Henneman EA Pham TA Mei YY Talati R Providers do not verify patient identity during computer order entry Acad Emerg Med 2008 15 641 8 http://dx.doi.org/10.1111/j.1553-2712.2008.00148.x 19086323 · DOI
  16. [21]Schulmeister L Patient misidentification in oncology care Clin J Oncol Nurs 2008 12 495 8 http://dx.doi.org/10.1188/08.CJON.495-498 18515248 · DOI
  17. [23]Lima-Oliveira G Salvagno GL Lippi G Gelati M Montagnana M Danese E Influence of a regular, standardized meal on clinical chemistry analytes Ann Lab Med 2012 32 250 6 http://dx.doi.org/10.3343/alm.2012.32.4.250 22779065 PMC3384805 · DOI · Paper page
  18. [24]Calmarza P Cordero J Lipemia interferences in routine clinical biochemical tests Biochem Med 2011 21 160 6 http://dx.doi.org/10.11613/BM.2011.025 22135856 · DOI
  19. [25]Won CS Oberlies NH Paine MF Mechanisms underlying food-drug interactions: inhibition of intestinal metabolism and transport Pharmacol Ther 2012 136 186 201 http://dx.doi.org/10.1016/j.pharmthera.2012.08.001 22884524 PMC3466398 · DOI
  20. [26]Tietz Fundamentals of Clinical Chemistry 6th edition Burtis CA Ashwood ER Bruns DE St Louis, MO Saunders/Elsevier 2008
  21. [27]Dasgupta A Review of abnormal laboratory test results and toxic effects due to use of herbal medicines Am J Clin Pathol 2003 120 127 37 http://dx.doi.org/10.1309/P024K7VRDDPJCTVN 12866383 · DOI
  22. [29]Hortin GL Homocysteine: Clinical Significance and Laboratory Measurement Lab Med 2006 37 551 3 http://dx.doi.org/10.1309/93G5JG1BF44N65BQ · DOI
  23. [30]Cooper GR Myers GL Smith SJ Schlant RC Blood lipid measurements. Variations and practical utility JAMA 1992 267 1652 60 http://dx.doi.org/10.1001/jama.267.12.1652 1542176 · DOI
  24. [32]Lucas C Donovan P ‘Just a repeat’ - When drug monitoring is indicated Aust Fam Physician 2013 42 18 22 23529454
  25. [33]Sidwell A Barclay M Begg E Moore G Digoxin therapeutic drug monitoring: an audit and review N Z Med J 2003 116 U708 14752536
  26. [34]Ain KB Pucino F Shiver TM Banks SM Thyroid hormone levels affected by time of blood sampling in thyroxine-treated patients Thyroid 1993 3 81 5 http://dx.doi.org/10.1089/thy.1993.3.81 8369656 · DOI · Paper page
  27. [35]Official Journal of the European Union EU Council Directive 2010/32/EU. Prevention of Sharps Injuries in the Hospital and Healthcare Sector Official Journal of the European Union, No. L134 of 1 6 2010 66 72
  28. [36]Thavendiranathan P Bagai A Ebidia A Detsky AS Choudhry NK Do blood tests cause anemia in hospitalized patients? The effect of diagnostic phlebotomy on hemoglobin and hematocrit levels J Gen Intern Med 2005 20 520 4 http://dx.doi.org/10.1111/j.1525-1497.2005.0094.x 15987327 PMC1490143 · DOI · Paper page
  29. [37]Dugan L Leech L Speroni KG Corriher J Factors affecting hemolysis rates in blood samples drawn from newly placed IV sites in the emergency department J Emerg Nurs 2005 31 338 45 http://dx.doi.org/10.1016/j.jen.2005.05.004 16126097 · DOI
  30. [38]Lima-Oliveira G Lippi G Salvagno GL Montagnana M Picheth G Guidi GC Impact of the phlebotomy training based on CLSI/NCCLS H03-a6 - procedures for the collection of diagnostic blood specimens by venipuncture Biochem Med 2012 22 342 51 http://dx.doi.org/10.11613/BM.2012.036 PMC3900046 23092065 · DOI · Paper page
  31. [39]Lippi G Salvagno GL Montagnana M Brocco G Guidi GC Influence of short-term venous stasis on clinical chemistry testing Clin Chem Lab Med 2005 43 869 75 http://dx.doi.org/10.1515/CCLM.2005.146 16201899 · DOI · Paper page
  32. [40]Lima-Oliveira G Lippi G Salvagno GL Montagnana M Manguera CL Sumita NM New ways to deal with known preanalytical issues: use of transilluminator instead of tourniquet for easing vein access and eliminating stasis on clinical biochemistry Biochem Med 2011 21 152 9 http://dx.doi.org/10.11613/BM.2011.024 22135855 · DOI · Paper page
  33. [41]Cengiz M Ulker P Meiselman HJ Baskurt OK Influence of tourniquet application on venous blood sampling for serum chemistry, hematological parameters, leukocyte activation and erythrocyte mechanical properties Clin Chem Lab Med 2009 47 769 76 http://dx.doi.org/10.1515/CCLM.2009.157 19426141 · DOI
  34. [43]Lima-Oliveira G Lippi G Salvagno GL Montagnana M Manguera CL Sumita NM New ways to deal with known preanalytical issues: use of transilluminator instead of tourniquet for easing vein access and eliminating stasis on clinical biochemistry Biochem Med 2011 21 152 9 http://dx.doi.org/10.11613/BM.2011.024 22135855 · DOI · Paper page
  35. [45]Salvagno GL Danese E Lima-Oliveira G Guidi GC Lippi G Avoidance to wipe alcohol before venipuncture is not a source of spurious hemolysis Biochem Med 2013 23 201 5 http://dx.doi.org/10.11613/BM.2013.023 PMC3900069 23894865 · DOI · Paper page
  36. [46]Fukugawa Y Ohnishi H Ishii T Tanouchi A Sano J Miyawaki H Effect of carryover of clot activators on coagulation tests during phlebotomy Am J Clin Pathol 2012 137 900 3 http://dx.doi.org/10.1309/AJCPL3LZZN9WJGZT 22586048 · DOI
  37. [47]Lima-Oliveira G Lippi G Salvagno GL Montagnana M Picheth G Guidi GC Incorrect order of draw could be mitigate the patient safety: a phlebotomy management case report Biochem Med 2013 23 218 23 http://dx.doi.org/10.11613/BM.2013.026 PMC3900060 23894868 · DOI · Paper page
  38. [50]Raijmakers MTM Menting CHF Vader HL van der Graaf F Collection of blood specimens by venipuncture for plasma-based coagulation assays: necessity of a discard tube Am J Clin Pathol 2010 133 331 5 http://dx.doi.org/10.1309/AJCP9ATB0AXPFJCC 20093244 · DOI
  39. [52]Serin E Bugdayci G Effect of tube filling order on specific coagulation parameters in healthy subjects Lab Med 2007 38 556 8 http://dx.doi.org/10.1309/RQ00WJ60-KQXAM9B0 · DOI
  40. [54]Favaloro EJ Lippi G Raijmakers MT Vader HL van der Graaf F Discard tubes are sometimes necessary when drawing samples for hemostasis Am J Clin Pathol 2010 134 851 http://dx.doi.org/10.1309/AJCP9HIFFC6FWKYF 20959673 · DOI

Cited by

Sorted by citations

Authors
Nikolac, N., Šupak Smolčić, V., Šimundić, A.-M., & Ćelap, I.
Affiliations
Croatian Society for Medical Biochemistry and Laboratory Medicine (HR)
Corresponding author
Nikolac, Nora
Venue
Biochemia Medica
Published
2013
Volume
23
Issue
3
Pages
242-254
ISSN
  • 1330-0962 (ISSN-L)
  • 1846-7482
OpenAlex
W2131396546
Cited by
99
References
3
Citations by year
2026: 3 · 2025: 5 · 2024: 6 · 2023: 7 · 2022: 4 · 2021: 3 · 2020: 5 · 2019: 13 · 2018: 7 · 2017: 12 · 2016: 8 · 2015: 8 · 2014: 17 · 2013: 1
FWCI
7.89
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Biochemia Medica (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • Hrčak Portal of scientific journals of Croatia (University Computing Centre) (submittedVersion, other-oa)
Topics
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Clinical Biochemistry › Bacterial Identification and Susceptibility Testing
  • Health Sciences › Medicine › Biochemistry › Blood transfusion and management
Keywords
phlebotomy, venipuncture, venous blood sampling, pre-analytical phase, blood sampling, national guidelines
MeSH terms
Humans, Croatia, Phlebotomy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review