Abstract
Fluorescent semiconductor nanocrystals (quantum dots [QDs]) are hypothesized to be excellent contrast agents for biomedical assays and imaging. A unique property of QDs is that their absorbance increases with increasing separation between excitation and emission wavelengths. Much of the enthusiasm for using QDs in vivo stems from this property, since photon yield should be proportional to the integral of the broadband absorption. In this study, we demonstrate that tissue scatter and absorbance can sometimes offset increasing QD absorption at bluer wavelengths, and counteract this potential advantage. By using a previously validated mathematical model, we explored the effects of tissue absorbance, tissue scatter, wavelength dependence of the scatter, water-to- hemoglobin ratio, and tissue thickness on QD performance. We conclude that when embedded in biological fluids and tissues, QD excitation wavelengths will often be quite constrained, and that excitation and emission wavelengths should be selected carefully based on the particular application. Based on our results, we produced near-infrared QDs optimized for imaging surface vasculature with white light excitation and a silicon CCD camera, and used them to image the coronary vasculature in vivo. Taken together, our data should prove useful in designing fluorescent QD contrast agents optimized for specific biomedical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Murray, C. B., Norris, D. J., & Bawendi, M. G. (1993) · Journal of the American Chemical Society · doi:10.1021/ja00072a025 · Cited by 9,282
Self-citationSemiconductor Nanocrystals as Fluorescent Biological Labels
Bruchez, M., Moronne, M., Gin, P., Weiss, S., & Alivisatos, A. P. (1998) · Science · doi:10.1126/science.281.5385.2013 · Cited by 8,613
Quantum Dot Bioconjugates for Ultrasensitive Nonisotopic Detection
Chan, W. C. W., & Nie, S. (1998) · Science · doi:10.1126/science.281.5385.2016 · Cited by 7,278
A clearer vision for in vivo imaging
Weissleder, R. (2001) · Nature Biotechnology · doi:10.1038/86684 · Cited by 3,839
In Vivo Imaging of Quantum Dots Encapsulated in Phospholipid Micelles
Dubertret, B., Skourides, P., Norris, D. J., Noireaux, V., Brivanlou, A. H., & Libchaber, A. (2002) · Science · doi:10.1126/science.1077194 · Cited by 3,019
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530 · cited 6×
“, skin [17]), the unique and desired property of QDs, namely, increasing excitation at bluer wavelengths, is largely preserved (Figure 4, solid line), and QDs emitting in Bands 1, 2, or 3 (Figure 5A) should perform well, with a slight overall advantage for Band 2.”
BackgroundMethodInfluentialWu, X., Liu, H., Liu, J., Haley, K. N., Treadway, J. A., Larson, J. P., Ge, N., Peale, F., & Bruchez, M. P. (2003) · Nature Biotechnology · doi:10.1038/nbt764 · Cited by 2,506
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456
Luminescent quantum dots for multiplexed biological detection and imaging
Chan, W. C. W., Maxwell, D. J., Gao, X., Bailey, R. E., Han, M., & Nie, S. (2002) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00282-3 · Cited by 2,068
Long-term multiple color imaging of live cells using quantum dot bioconjugates
Jaiswal, J. K., Mattoussi, H., Mauro, J. M., & Simon, S. M. (2003) · Nature Biotechnology · doi:10.1038/nbt767 · Cited by 1,999
Research works printed but not linked: 8
- 10.1038/35097256 · doi:10.1038/35097256
- 10.1117/1.1352748 · DOI
- 10.1002/(SICI)1520-6343(1997)3:3<225::AID-BSPY6>3.0.CO;2-4 · doi:10.1002/(sici)1520-6343(1997)3:3<225::aid-bspy6>3.0.co;2-4
- Jacques SL, 1999, Oregon Medical Laser Center News., 1999
- 10.1097/00005344-200110000-00011 · doi:10.1097/00005344-200110000-00011
- 10.1088/0031-9155/45/12/319 · DOI
- Chen F, 2002, Mater Res Soc Symp Proc., 691, 359
- 10.1002/(SICI)1521-4095(199905)11:7<552::AID-ADMA552>3.0.CO;2-Q · DOI
Cited by
Items 101–109 of 109
Nanotechnology for cancer diagnostics: promises and challenges
Grodzinski, P., Silver, M., & Molnar, L. K. (2006) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.6.3.307 · Cited by 180
Smith, A. M., & Nie, S. (2011) · Journal of the American Chemical Society · doi:10.1021/ja108482a · Cited by 172
NIR luminescent nanomaterials for biomedical imaging
Wang, R., & Zhang, F. (2014) · Journal of Materials Chemistry B · doi:10.1039/c3tb21447h · Cited by 170
Real-Time Fluorescence Image-Guided Oncologic Surgery
(2014) · Advances in Cancer Research · doi:10.1016/b978-0-12-411638-2.00005-7 · Cited by 163
“Recent studies suggest that the 1300 nm spectral range further improves imaging depth (Lim et al., 2003) and has generated interest in the second optical window of 1000 nm – 1350 nm which can afford much higher depths of penetration (Smith, Mancini and Nie, 2009).”
BackgroundSolution-Processed Quantum Dot Photodetectors
Konstantatos, G., & Sargent, E. H. (2009) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2025612 · Cited by 160
“Sensitive photodetection in the short wavelength infrared (SWIR), on the other hand, enables passive night vision [1], [2] from 1 to 1.7 � m and biomedical imaging for tumor detection [3] exploiting the tissue transparent windows around 900 and 1100 nm [ 4 ], [5].”
BackgroundInfluentialLabeling tumor cells with fluorescent nanocrystal–aptamer bioconjugates
Chu, T. C., Shieh, F., Lavery, L. A., Levy, M., Richards-Kortum, R., Korgel, B. A., & Ellington, A. D. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.12.015 · Cited by 160
“Tissue scatter constrains both the exciation and emission wavelengths of optical probes to the far-red nd near-infrared regions of the visible spectrum, making the arrower band gap exhibited by CdTe nanocrystals better suited or in vivo imaging than CdSe (Lim et al., 2003).”
BackgroundInfluentialMcVeigh, E. R. (2006) · Circulation Research · doi:10.1161/01.res.0000216870.73358.d9 · Cited by 159
Wong, K. C. Y., & Sletten, E. M. (2022) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2022.102131 · Cited by 31
Nishimura, G., Kida, I., & Tamura, M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/11/021 · Cited by 20
Metadata
- Authors
- Lim, Y. T., Kim, S., Nakayama, A., Stott, N. E., Bawendi, M. G., & Frangioni, J. V.
- Venue
- Molecular Imaging
- Publisher
- SAGE Publications
- Published
- 2003-01-01
- Volume
- 2
- Issue
- 1
- Pages
- 50-64
- ISSN
- 1535-3508 (ISSN-L)
- 1536-0121
- OpenAlex
- W2143345040
- Cited by
- 559
- References
- 39
- FWCI
- 12.72
- Type
- journal article
- Language
- en
- Open access
- gold
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.