The DOI matches its Crossref record.
Dendrimer-based Macromolecular MRI Contrast Agents: Characteristics and Application
Open accessAbstract
Numerous macromolecular MRI contrast agents prepared employing relatively simple chemistry may be readily available that can provide sufficient enhancement for multiple applications. These agents operate using a ~100-fold lower concentration of gadolinium ions in comparison to the necessary concentration of iodine employed in CT imaging. Herein, we describe some of the general potential directions of macromolecular MRI contrast agents using our recently reported families of dendrimer-based agents as examples. Changes in molecular size altered the route of excretion. Smaller-sized contrast agents less than 60 kDa molecular weight were excreted through the kidney resulting in these agents being potentially suitable as functional renal contrast agents. Hydrophilic and larger-sized contrast agents were found better suited for use as blood pool contrast agents. Hydrophobic variants formed with polypropylenimine diaminobutane dendrimer cores created liver contrast agents. Larger hydrophilic agents are useful for lymphatic imaging. Finally, contrast agents conjugated with either monoclonal antibodies or with avidin are able to function as tumor-specific contrast agents, which also might be employed as therapeutic drugs for either gadolinium neutron capture therapy or in conjunction with radioimmunotherapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 70
- 10.1097/00004424-198708000-00008 · DOI · Paper page
- 10.1097/00004424-199411000-00004 · doi:10.1097/00004424-199411000-00004
- 10.1002/jmri.1880070110 · DOI · Paper page
- 10.1097/00004424-198908000-00007 · doi:10.1097/00004424-198908000-00007
- 10.1016/S0925-8388(96)02830-7 · DOI
- Watanabe N, 1994, Cancer Res., 54, 1049
- 10.1007/BF02668094 · DOI · Paper page
- 10.1055/s-2002-19551 · doi:10.1055/s-2002-19551
- 10.1097/00004424-199111000-00008 · doi:10.1097/00004424-199111000-00008
- 10.1002/jmri.1880040325 · doi:10.1002/jmri.1880040325
- 10.1097/00004424-199205000-00004 · doi:10.1097/00004424-199205000-00004
- 10.1148/radiology.187.3.8497616 · DOI · Paper page
- 10.1148/radiology.175.2.1691513 · doi:10.1148/radiology.175.2.1691513
- 10.1016/0730-725X(96)00020-3 · doi:10.1016/0730-725x(96)00020-3
- 10.1097/00004424-199605000-00008 · doi:10.1097/00004424-199605000-00008
- 10.2214/ajr.162.5.8165978 · doi:10.2214/ajr.162.5.8165978
- 10.1002/jmri.1880040337 · doi:10.1002/jmri.1880040337
- 10.1148/radiology.198.2.8596833 · doi:10.1148/radiology.198.2.8596833
- 10.1021/bc000091p · DOI
- 10.1002/3527600612 · DOI · Paper page
- 10.1002/anie.199001381 · DOI · Paper page
- 10.1016/S0168-3659(99)00246-1 · DOI · Paper page
- 10.1016/0960-894X(94)80014-6 · DOI
- 10.1093/clinchem/40.9.1845 · doi:10.1093/clinchem/40.9.1845
- 10.1021/bc00025a008 · DOI · Paper page
- 10.1021/bc980091d · DOI
- 10.1007/s002590000293 · doi:10.1007/s002590000293
- 10.1097/00004424-199809000-00026 · DOI
- 10.2214/ajr.174.5.1741385 · doi:10.2214/ajr.174.5.1741385
- 10.1002/mrm.1314 · DOI
- Kobayashi H, Kawamoto S, Jo S, Bryant LHJr., Brechbiel MW, Star RA (in press). Macromolecular MRI contrast agents with small dendrimers: Pharmacokinetic differences between sizes and cores. Bioconjug Chem.
- 10.1002/mrm.1910310102 · DOI · Paper page
- 10.1002/1522-2594(200103)45:3<454::AID-MRM1060>3.0.CO;2-M · doi:10.1002/1522-2594(200103)45:3<454::aid-mrm1060>3.0.co;2-m
- 10.1002/jmri.10025 · DOI
- 10.1007/s002590000276 · DOI · Paper page
- Wiseman GA, 1999, Clin Cancer Res., 5, 3281s
- 10.1002/mrm.1257 · doi:10.1002/mrm.1257
- Kobayashi H, 2001, Cancer Res., 61, 4966
- 10.1002/mrm.1259 · doi:10.1002/mrm.1259
- 10.1021/bc010002o · doi:10.1021/bc010002o
- 10.1021/bc000075s · doi:10.1021/bc000075s
- 10.1002/mrm.1910220225 · DOI · Paper page
- 10.1148/radiology.198.3.8628876 · DOI · Paper page
- 10.1002/mrm.1230 · doi:10.1002/mrm.1230
- Shirakawa K, 2002, Cancer Res., 62, 560
- Kobayashi H, 2002, Cancer Res., 62, 860
- 10.1002/mrm.1214 · doi:10.1002/mrm.1214
- Behr TM, 1995, Cancer Res., 55, 3825
- Kobayashi H, 1996, Cancer Res., 56, 3788
- Kobayashi H, 2000, J Nucl Med., 41, 755
- 10.1148/radiology.170.3.2916025 · doi:10.1148/radiology.170.3.2916025
- 10.1097/00004728-198905000-00016 · doi:10.1097/00004728-198905000-00016
- 10.1002/mrm.1910220233 · doi:10.1002/mrm.1910220233
- 10.1046/j.1523-1755.2002.00364.x · DOI
- Kobayashi H, 2003, Cancer Res., 63, 271
- 10.1248/bpb.23.97 · DOI
- 10.1002/mrm.1910330113 · doi:10.1002/mrm.1910330113
- 10.1007/BF02594598 · DOI
- 10.1097/00004424-200203000-00007 · doi:10.1097/00004424-200203000-00007
- 10.1016/S1076-6332(96)80193-0 · doi:10.1016/s1076-6332(96)80193-0
- 10.2214/ajr.158.1.1727343 · doi:10.2214/ajr.158.1.1727343
- 10.1002/1522-2586(200011)12:5<734::AID-JMRI10>3.0.CO;2-R · doi:10.1002/1522-2586(200011)12:5<734::aid-jmri10>3.0.co;2-r
- 10.2214/ajr.159.4.1529857 · doi:10.2214/ajr.159.4.1529857
- 10.2214/ajr.161.1.8517301 · doi:10.2214/ajr.161.1.8517301
- 10.1097/00004424-199512000-00003 · DOI
- 10.1148/radiology.191.1.8134576 · DOI
- 10.1097/00004424-199712000-00005 · DOI · Paper page
- 10.1097/00004424-200001000-00006 · DOI
- 10.1016/S1064-9689(21)00560-2 · DOI
- 10.1038/nm0598-623 · DOI · Paper page
Cited by
Dendrimers in biomedical applications—reflections on the field
SVENSON, S., & TOMALIA, D. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2005.09.018 · Cited by 1,919
Kobayashi, H., Watanabe, R., & Choyke, P. L. (2014) · Theranostics · doi:10.7150/thno.7193 · Cited by 996
Self-citationDendrimers in biomedical applications—reflections on the field
Svenson, S., & Tomalia, D. A. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.030 · Cited by 593
Nanoparticles: Emerging carriers for drug delivery
Mudshinge, S. R., Deore, A. B., Patil, S., & Bhalgat, C. M. (2011) · Saudi Pharmaceutical Journal · doi:10.1016/j.jsps.2011.04.001 · Cited by 543
Dendrimers in Oncology: An Expanding Horizon
Tekade, R. K., Kumar, P. V., & Jain, N. K. (2009) · Chemical Reviews · doi:10.1021/cr068212n · Cited by 466
Metadata
- Authors
- Kobayashi, H., & Brechbiel, M. W.
- Venue
- Molecular Imaging
- Publisher
- SAGE Publications
- Published
- 2003-01-01
- Volume
- 2
- Issue
- 1
- Pages
- 1-10
- ISSN
- 1535-3508 (ISSN-L)
- 1536-0121
- OpenAlex
- W2133532535
- Cited by
- 202
- References
- 0
- FWCI
- 14.03
- Type
- journal article
- Language
- en
- Open access
- gold
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dendrimer-based Macromolecular MRI Contrast Agents: Characteristics and Application. https://app.cochat.ai/papers/10.1162/15353500200303100
- The paper
- Kobayashi, H., & Brechbiel, M. W. (2003). Dendrimer-based Macromolecular MRI Contrast Agents: Characteristics and Application. Molecular Imaging. https://doi.org/10.1162/15353500200303100
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.