Adaptive Decoding for Brain-Machine Interfaces Through Bayesian Parameter Updates
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Brain-machine interfaces (BMIs) transform the activity of neurons recorded in motor areas of the brain into movements of external actuators. Representation of movements by neuronal populations varies over time, during both voluntary limb movements and movements controlled through BMIs, due to motor learning, neuronal plasticity, and instability in recordings. To ensure accurate BMI performance over long time spans, BMI decoders must adapt to these changes. We propose the Bayesian regression self-training method for updating the parameters of an unscented Kalman filter decoder. This novel paradigm uses the decoder's output to periodically update its neuronal tuning model in a Bayesian linear regression. We use two previously known statistical formulations of Bayesian linear regression: a joint formulation, which allows fast and exact inference, and a factorized formulation, which allows the addition and temporary omission of neurons from updates but requires approximate variational inference. To evaluate these methods, we performed offline reconstructions and closed-loop experiments with rhesus monkeys implanted cortically with microwire electrodes. Offline reconstructions used data recorded in areas M1, S1, PMd, SMA, and PP of three monkeys while they controlled a cursor using a handheld joystick. The Bayesian regression self-training updates significantly improved the accuracy of offline reconstructions compared to the same decoder without updates. We performed 11 sessions of real-time, closed-loop experiments with a monkey implanted in areas M1 and S1. These sessions spanned 29 days. The monkey controlled the cursor using the decoder with and without updates. The updates maintained control accuracy and did not require information about monkey hand movements, assumptions about desired movements, or knowledge of the intended movement goals as training signals. These results indicate that Bayesian regression self-training can maintain BMI control accuracy over long periods, making clinical neuroprosthetics more viable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to Variational Methods for Graphical Models
Jordan, M. I., Ghahramani, Z., Jaakkola, T. S., & Saul, L. K. (1999) · Machine Learning · doi:10.1023/a:1007665907178 · Cited by 3,791
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 2×
“…for translating recorded neuronal signals into movement commands assumed static neuronal tuning (Wessberg et al., 2000; Serruya, Hatsopoulos, Paninski, Fellows, & Donoghue , 2002; Carmena et al., 2003; Hochberg et al., 2006; Wu, Gao, Bienenstock, Donoghue, & Black, 2006; Ganguly & Carmena, 2009).”
BackgroundLearning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761 · cited 2×
“We included neurons from S1 for predictions because prior work has found that they can be used for decoding arm movements (Carmena et al., 2003).”
BackgroundMethodSelf-citationCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Cognitive Control Signals for Neural Prosthetics
Musallam, S., Corneil, B. D., Greger, B., Scherberger, H., & Andersen, R. A. (2004) · Science · doi:10.1126/science.1097938 · Cited by 663
(2005) · Edinburgh Research Explorer (University of Edinburgh) · doi:10.5555/1046920.1088695 · Cited by 650
Emergence of a stable cortical map for neuroprosthetic control
Ganguly, K., & Carmena, J. M. (2009) · PLoS Biology · doi:10.1371/journal.pbio.1000153 · Cited by 578 · cited 2×
“Studies have shown that baseline firing rates of neurons change over time (Chestek et al., 2007; Ganguly & Carmena, 2009) and so the means should be updated.”
Background
Cited by
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Self-citationA high-performance neural prosthesis enabled by control algorithm design
Gilja, V., Nuyujukian, P., Chestek, C. A., Cunningham, J. P., Yu, B. M., Fan, J. M., Churchland, M. M., Kaufman, M. T., Kao, J. C., Ryu, S. I., et al. (2012) · Nature Neuroscience · doi:10.1038/nn.3265 · Cited by 564
Restoring sensorimotor function through intracortical interfaces: progress and looming challenges
Bensmaia, S. J., & Miller, L. E. (2014) · Nature Reviews Neuroscience · doi:10.1038/nrn3724 · Cited by 368
Closed-Loop Decoder Adaptation Shapes Neural Plasticity for Skillful Neuroprosthetic Control
Orsborn, A. L., Moorman, H. G., Overduin, S. A., Shanechi, M. M., Dimitrov, D. F., & Carmena, J. M. (2014) · Neuron · doi:10.1016/j.neuron.2014.04.048 · Cited by 280
A survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Metadata
- Authors
- Li, Z., O'Doherty, J. E., Lebedev, M. A., & Nicolelis, M. A. L.
- Venue
- Neural Computation
- Publisher
- MIT Press - Journals
- Published
- 2011-12
- Volume
- 23
- Issue
- 12
- Pages
- 3162-3204
- ISSN
- 0899-7667 (ISSN-L)
- 1530-888X
- OpenAlex
- W2136988120
- Cited by
- 128
- References
- 8
- FWCI
- 7.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adaptive Decoding for Brain-Machine Interfaces Through Bayesian Parameter Updates. https://app.cochat.ai/papers/10.1162/neco_a_00207
- The paper
- Li, Z., O'Doherty, J. E., Lebedev, M. A., & Nicolelis, M. A. L. (2011). Adaptive Decoding for Brain-Machine Interfaces Through Bayesian Parameter Updates. Neural Computation. https://doi.org/10.1162/neco_a_00207
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.