PEG-cross-linked heparin is an affinity hydrogel for sustained release of vascular endothelial growth factor
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
An affinity-based controlled release system for growth factors having heparin-binding domains was prepared using a cross-linked heparin gel. The heparin gel was made by reacting hydrazide-functionalized heparin (Hep-ADH) with the N-hydroxysuccinimidyl ester of poly(ethylene glycol)-bis-butanoic acid (SBA-PEG-SBA). The degree of cross-linking could be controlled by defining the stoichiometry of hydrazide modification and the PEG cross-linker addition. The release of vascular endothelial growth factor (VEGF) was characterized as a heparin-binding growth factor. VEGF was directly injected into the heparin gel and the loaded VEGF displayed a slow, controlled release over 3 weeks with little initial burst phase. The biological activity of the released VEGF was measured with a proliferation assay utilizing human umbilical vein endothelial cells. The released VEGF maintained its biological activity at all time points investigated. The heparin gel with loaded VEGF was implanted sub-cutaneously in the dorsal region of mice. A significantly increased density of the endothelial cell marker platelet endothelial adhesion molecule (PECAM-1) was observed in histological specimens of the tissues surrounding the implanted gel.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vascular-specific growth factors and blood vessel formation
Yancopoulos, G. D., Davis, S., Gale, N. W., Rudge, J. S., Wiegand, S. J., & Holash, J. (2000) · Nature · doi:10.1038/35025215 · Cited by 3,699
Cited by
Bioactive modification of poly (ethylene glycol) hydrogels for tissue engineering
Zhu, J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.02.044 · Cited by 1,457
3D printing of hydrogels: Rational design strategies and emerging biomedical applications
Li, J., Wu, C., Chu, P. K., & Gelinsky, M. (2020) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2020.100543 · Cited by 862
Hydrogel‐Based Growth Factor Delivery Platforms: Strategies and Recent Advances
Shan, B., & Wu, F. (2024) · Advanced Materials · doi:10.1002/adma.202210707 · Cited by 430
Approaches to neural tissue engineering using scaffolds for drug delivery
Willerth, S. M., & Sakiyama-Elbert, S. E. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.03.014 · Cited by 392
Supramolecular engineering of hydrogels for drug delivery
Bernhard, S., & Tibbitt, M. W. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.02.002 · Cited by 363
Metadata
- Authors
- Tae, G., Scatena, M., Stayton, P. S., & Hoffman, A. S.
- Venue
- Journal of Biomaterials Science, Polymer Edition
- Publisher
- Informa UK Limited
- Published
- 2006-01
- Volume
- 17
- Issue
- 1-2
- Pages
- 187-197
- ISSN
- 0920-5063 (ISSN-L)
- 1568-5624
- OpenAlex
- W2093169400
- Cited by
- 147
- References
- 1
- FWCI
- 3.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.