Electrospinning versus knitting: two scaffolds for tissue engineering of the aortic valve
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Two types of scaffolds were developed for tissue engineering of the aortic valve; an electrospun valvular scaffold and a knitted valvular scaffold. These scaffolds were compared in a physiologic flow system and in a tissue-engineering process. In fibrin gel enclosed human myofibroblasts were seeded onto both types of scaffolds and cultured for 23 days under continuous medium perfusion. Tissue formation was evaluated by confocal laser scanning microscopy, histology and DNA quantification. Collagen formation was quantified by a hydroxyproline assay. When subjected to physiologic flow, the spun scaffold tore within 6 h, whereas the knitted scaffold remained intact. Cells proliferated well on both types of scaffolds, although the cellular penetration into the spun scaffold was poor. Collagen production, normalized to DNA content, was not significantly different for the two types of scaffolds, but seeding efficiency was higher for the spun scaffold, because it acted as a cell impermeable filter. The knitted tissue constructs showed complete cellular in-growth into the pores. An optimal scaffold seems to be a combination of the strength of the knitted structure and the cell-filtering ability of the spun structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The effect of scaffold degradation rate on three-dimensional cell growth and angiogenesis
Sung, H.-J., Meredith, C., Johnson, C., & Galis, Z. S. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.066 · Cited by 804
Cited by
The return of a forgotten polymer—Polycaprolactone in the 21st century
Woodruff, M. A., & Hutmacher, D. W. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.04.002 · Cited by 4,033
Nanostructured materials for applications in drug delivery and tissue engineering
Goldberg, M., Langer, R., & Jia, X. (2007) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856207779996931 · Cited by 1,054
Progress in the Field of Electrospinning for Tissue Engineering Applications
Agarwal, S., Wendorff, J. H., & Greiner, A. (2009) · Advanced Materials · doi:10.1002/adma.200803092 · Cited by 523
Recent Advances in Bioplastics: Application and Biodegradation
Narancic, T., Cerrone, F., Beagan, N., & O’Connor, K. E. (2020) · Polymers · doi:10.3390/polym12040920 · Cited by 421
Improved Cellular Infiltration in Electrospun Fiber via Engineered Porosity
Nam, J., Huang, Y., Agarwal, S., & Lannutti, J. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0306 · Cited by 414
Electrospun Fibrous Mats with High Porosity as Potential Scaffolds for Skin Tissue Engineering
Zhu, X., Cui, W., Li, X., & Jin, Y. (2008) · Biomacromolecules · doi:10.1021/bm800476u · Cited by 383
Electrospun cellular microenvironments: Understanding controlled release and scaffold structure
Szentivanyi, A., Chakradeo, T., Zernetsch, H., & Glasmacher, B. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.12.002 · Cited by 271
Substrates for cardiovascular tissue engineering
Bouten, C. V. C., Dankers, P. Y. W., Driessen-Mol, A., Pedron, S., Brizard, A. M. A., & Baaijens, F. P. T. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.007 · Cited by 261
Self-citationDesign and preparation of polymeric scaffolds for tissue engineering
Weigel, T., Schinkel, G., & Lendlein, A. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.3.6.835 · Cited by 228
Biomechanics and mechanobiology in functional tissue engineering
Guilak, F., Butler, D. L., Goldstein, S. A., & Baaijens, F. P. T. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.04.019 · Cited by 228
“…have been applied to the development of scaffolds and constructs with highly biomimetic properties, as well as the ability to provide cell-instructive signals (Almeida et al., 2013; Brunger et al., 2014; Freeman et al., 2011; Liberski et al., 2011; Moutos et al., 2007; van Lieshout et al., 2006).”
BackgroundSelf-citationMultiscale three-dimensional scaffolds for soft tissue engineering via multimodal electrospinning
Soliman, S., Pagliari, S., Rinaldi, A., Forte, G., Fiaccavento, R., Pagliari, F., Franzese, O., Minieri, M., Di Nardo, P., Licoccia, S., et al. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.10.051 · Cited by 226
“Hence, in its simplest form the design problem for a unimodal electrospun scaffold may be reduced to selection of the proper fiber distribution to deliver the optimal trade-off between sufficiently large pores and as small as possible fibers [20,31].”
BackgroundBaker, S. R., Banerjee, S., Bonin, K., & Guthold, M. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.09.102 · Cited by 224
Textile Technologies and Tissue Engineering: A Path Toward Organ Weaving
Akbari, M., Tamayol, A., Bagherifard, S., Serex, L., Mostafalu, P., Faramarzi, N., Mohammadi, M. H., & Khademhosseini, A. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201500517 · Cited by 215
Aortic valve disease and treatment: The need for naturally engineered solutions
Butcher, J. T., Mahler, G. J., & Hockaday, L. A. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.008 · Cited by 210
“Motor controlled electrospinning and knitting have also been used to create TEHV with prescribed polymer fiber architectures [463,464].”
MethodBalguid, A., Mol, A., van Marion, M. H., Bank, R. A., Bouten, C. V. C., & Baaijens, F. P. T. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2007.0294 · Cited by 194
Self-citationFibrous scaffolds for building hearts and heart parts
Capulli, A. K., MacQueen, L. A., Sheehy, S. P., & Parker, K. K. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.11.020 · Cited by 130
“”Because of this “bottom-up” approach, scaffold characteristics such as fiber diameter [187], fiber alignment [26], scaffold porosity for cell infiltration [188], and macroscopic scaffold geometry [189] can be controlled by simply varyingneedle diameter, applied needle voltage,flow rate or viscosity of solution/melt,…”
JetValve: Rapid manufacturing of biohybrid scaffolds for biomimetic heart valve replacement
Capulli, A. K., Emmert, M. Y., Pasqualini, F. S., Kehl, D., Caliskan, E., Lind, J. U., Sheehy, S. P., Park, S. J., Ahn, S., Weber, B., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.04.033 · Cited by 112
Metadata
- Authors
- van Lieshout, M. I., Vaz, C. M., Rutten, M. C. M., Peters, G. W. M., & Baaijens, F. P. T.
- Venue
- Journal of Biomaterials Science, Polymer Edition
- Publisher
- Informa UK Limited
- Published
- 2006-01
- Volume
- 17
- Issue
- 1-2
- Pages
- 77-89
- ISSN
- 0920-5063 (ISSN-L)
- 1568-5624
- OpenAlex
- W2096303359
- Cited by
- 97
- References
- 1
- FWCI
- 3.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.