Injectable PLGA microsphere/calcium phosphate cements: physical properties and degradation characteristics
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Calcium phosphate (CaP) cements show an excellent biocompatibility and often have a high mechanical strength, but in general degrade relatively slow. To increase degradation rates, macropores can be introduced into the cement, e.g., by the inclusion of biodegradable microspheres into the cement. The aim of this research is to develop an injectable PLGA microsphere/CaP cement with sufficient setting/cohesive properties and good mechanical and physical properties. PLGA microspheres were prepared using a water-in-oil-in-water double-emulsion technique. The CaP-cement used was Calcibon, a commercially available hydroxyapatite-based cement. 10:90 and 20:80 dry wt% PLGA microsphere/CaP cylindrical scaffolds were prepared as well as microporous cement (reference material). Injectability, setting time, cohesive properties and porosity were determined. Also, a 12-week degradation study in PBS (37 degree C) was performed. Results showed that injectability decreased with an increase in PLGA microsphere content. Initial and final setting time of the PLGA/CaP samples was higher than the microporous sample. Porosity of the different formulations was 40.8% (microporous), 60.2% (10:90) and 69.3% (20:80). The degradation study showed distinct mass loss and a pH decrease of the surrounding medium starting from week 6 with the 10:90 and 20:80 formulations, indicating PLGA erosion. Compression strength of the PLGA microsphere/CaP samples decreased siginificantly in time, the microporous sample remained constant. After 12 weeks both PLGA/CaP samples showed a structure of spherical micropores and had a compressive strength of 12.2 MPa (10:90) and 4.3 MPa (20:80). Signs of cement degradation were also found with the 20:80 formulation. In conclusion, all physical parameters were well within workable ranges with both 10:90 and 20:80 PLGA microsphere/CaP cements. After 12 weeks the PLGA was totally degraded and a highly porous, but strong scaffold remained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanisms of polymer degradation and erosion
Göpferich, A. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85755-3 · Cited by 1,781
Why degradable polymers undergo surface erosion or bulk erosion
Burkersroda, F. V., Schedl, L., & Göpferich, A. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00170-9 · Cited by 1,146
Potential of ceramic materials as permanently implantable skeletal prostheses
Hulbert, S. F., Young, F. A., Mathews, R. S., Klawitter, J. J., Talbert, C. D., & Stelling, F. H. (1970) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820040309 · Cited by 1,019
The Optimum Pore Size for the Fixation of Porous-Surfaced Metal Implants by the Ingrowth of Bone
BOBYN, J. D., PILLIAR, R. M., CAMERON, H. U., & WEATHERLY, G. C. (1980) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198007000-00045 · Cited by 832
Injectability of calcium phosphate pastes
Bohner, M., & Baroud, G. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.05.010 · Cited by 395
Pore diameter of more than 100 μm is not requisite for bone ingrowth in rabbits
Itälä, A. I., Ylänen, H. O., Ekholm, C., Karlsson, K. H., & Aro, H. T. (2001) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1069 · Cited by 379
Physico-chemical characterization of Ca-alginate microparticles produced with different methods
Fundueanu, G., Nastruzzi, C., Carpov, A., Desbrieres, J., & Rinaudo, M. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00050-2 · Cited by 318
Fast setting calcium phosphate–chitosan scaffold: mechanical properties and biocompatibility
Xu, H. H. K., & Simon, C. G. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.04.043 · Cited by 270
A new method to produce macropores in calcium phosphate cements
del Real, R. P., Wolke, J. G. C., Vallet-Regı́, M., & Jansen, J. A. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00101-1 · Cited by 265
Self-citationPLG Microsphere Size Controls Drug Release Rate Through Several Competing Factors
Berkland, C., Kim, K., & Pack, D. W. (2003) · Pharmaceutical Research · doi:10.1023/a:1024466407849 · Cited by 219
Holland, T. A., Tessmar, J. K. V., Tabata, Y., & Mikos, A. G. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2003.09.007 · Cited by 208
Self-citationRUHE, Q. P., HEDBERG, E. L., PADRON, N. T., SPAUWEN, P. H. M., JANSEN, J. A., & MIKOS, A. G. (2003) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200300003-00013 · Cited by 186
Self-citationControlled release of transforming growth factor ?1 from biodegradable polymer microparticles
Lu, L., Stamatas, G. N., & Mikos, A. G. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(20000605)50:3<440::aid-jbm19>3.0.co;2-g · Cited by 170
Self-citationXu, H. H. K., Quinn, J. B., Takagi, S., Chow, L. C., & Eichmiller, F. C. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20011205)57:3<457::aid-jbm1189>3.0.co;2-x · Cited by 158
Simon, C. G., Khatri, C. A., Wight, S. A., & Wang, F. W. (2002) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(01)00140-1 · Cited by 118
Controlled release of an osteogenic peptide from injectable biodegradable polymeric composites
Hedberg, E. L., Tang, A., Crowther, R. S., Carney, D. H., & Mikos, A. G. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(02)00261-4 · Cited by 117
Self-citationAthanasiou, K. A., Schmitz, J. P., & Agrawal, C. M. (1998) · Tissue Engineering · doi:10.1089/ten.1998.4.53 · Cited by 110
Effect of calcium carbonate on clinical compliance of apatitic calcium phosphate bone cement
Khairoun, I., Boltong, M. G., Driessens, F. C. M., & Planell, J. A. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199724)38:4<356::aid-jbm8>3.0.co;2-n · Cited by 98
In vitro characterization and in vivo properties of a carbonated apatite bone cement
Khairoun, I., Magne, D., Gauthier, O., Bouler, J., Aguado, E., Daculsi, G., & Weiss, P. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10132 · Cited by 67
A detailed characterization of polyglycolide prepared by solid-state polycondensation reaction
Schwarz, K., & Epple, M. (1999) · Macromolecular Chemistry and Physics · doi:10.1002/(sici)1521-3935(19991001)200:10<2221::aid-macp2221>3.0.co;2-q · Cited by 63
POE/PLGA composite microspheres: formation and in vitro behavior of double walled microspheres
Yang, Y. Y., Shi, M., Goh, S.-H., Moochhala, S., Ng, S., & Heller, J. (2003) · Journal of Controlled Release · doi:10.1016/s0168-3659(02)00491-1 · Cited by 62
Schwach, G., Oudry, N., Delhomme, S., Lück, M., Lindner, H. R., & Gurny, R. (2003) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/s0939-6411(03)00096-1 · Cited by 52
Effect of Ganciclovir on the Hydrolytic Degradation of Poly(lactide-co-glycolide) Microspheres
Chen, X., Ooi, C. P., & Lim, T. H. (2006) · Journal of Biomaterials Applications · doi:10.1177/0885328206054265 · Cited by 46
Kempen, D. H. R., Lu, L., Zhu, X., Kim, C. W., Jabbari, E., Dhert, W. J. A., Currier, B. L., & Yaszemski, M. J. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30079 · Cited by 28
Agrawal (1997) · doi:10.1002/(sici)1097-4636(199722)38:2<105::aid-jbm4>3.0.co;2-u
Cited by
An Overview of Poly(lactic-co-glycolic) Acid (PLGA)-Based Biomaterials for Bone Tissue Engineering
Gentile, P., Chiono, V., Carmagnola, I., & Hatton, P. (2014) · International Journal of Molecular Sciences · doi:10.3390/ijms15033640 · Cited by 1,593
“Amorphous PLGA copolymers are suitable for biomedical applications, as provides a more homogeneous dispersion of the active species in the polymer matrix [80].”
BackgroundInjectable matrices and scaffolds for drug delivery in tissue engineering
Kretlow, J. D., Klouda, L., & Mikos, A. G. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.03.013 · Cited by 629
Self-citationCeramic composites as matrices and scaffolds for drug delivery in tissue engineering
Habraken, W. J. E. M., Wolke, J. G. C., & Jansen, J. A. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.03.011 · Cited by 566
Self-citationBone tissue engineering therapeutics: controlled drug delivery in three-dimensional scaffolds
Mouriño, V., & Boccaccini, A. R. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0379 · Cited by 527
Review: Mineralization of Synthetic Polymer Scaffolds for Bone Tissue Engineering
Kretlow, J. D., & Mikos, A. G. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0394 · Cited by 343
Self-citation
Metadata
- Authors
- Habraken, W. J. E. M., Wolke, J. G. C., Mikos, A. G., & Jansen, J. A.
- Venue
- Journal of Biomaterials Science, Polymer Edition
- Publisher
- Informa UK Limited
- Published
- 2006-01
- Volume
- 17
- Issue
- 9
- Pages
- 1057-1074
- ISSN
- 0920-5063 (ISSN-L)
- 1568-5624
- OpenAlex
- W2123714740
- Cited by
- 192
- References
- 25
- FWCI
- 10.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.