CoChat

Application of an elastic biodegradable poly(L-lactide-co-ε-caprolactone) scaffold for cartilage tissue regeneration

Jung, Youngmee, Kim, Soo Hyun, You, Hee Jin, Kim, Sang-Heon, Ha Kim, Young, Min, Byoung Goo · 2008 · Journal of Biomaterials Science, Polymer Edition
Cited by 51

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

In cartilage tissue regeneration, it is important that an implant inserted into a defect site can maintain its mechanical integrity and endure stress loads from the body, in addition to being biocompatible and able to induce tissue growth. These factors are crucial in the design of scaffolds for cartilage tissue engineering. We developed an elastic biodegradable scaffold from poly(L-lactideco-epsilon-caprolactone) (PLCL) for application in cartilage treatment. Biodegradable PLCL co-polymer was synthesized from L-lactide and epsilon-caprolactone in the presence of stannous octoate as a catalyst. A highly elastic PLCL scaffold was fabricated by a gel-pressing method with 80% porosity and 300-500 microm pore size. The tensile mechanical and recovery tests were performed in order to examine mechanical and elastic properties of the PLCL scaffold. They could be easily twisted and bent and exhibited almost complete (over 94%) recoverable extension up to breaking point. For examining cartilaginous tissue formation, rabbit chondrocytes were seeded on scaffolds. They were then cultured in vitro for 5 weeks or implanted in nude mice subcutaneously. From in vitro and in vivo tests, the accumulation of extracellular matrix on the constructs showed that chondrogenic differentiation was sustained onto PLCL scaffolds. Histological analysis showed that cells onto PLCL scaffolds formed mature and well-developed cartilaginous tissue, as evidenced by chondrocytes within lacunae. From these results, we are confident that elastic PLCL scaffolds exhibit biocompatibility and as such would provide an environment where cartilage tissue growth is enhanced and facilitated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1163/156856208784909336

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 51

Metadata

Authors
Jung, Y., Kim, S. H., You, H. J., Kim, S.-H., Ha Kim, Y., & Min, B. G.
Venue
Journal of Biomaterials Science, Polymer Edition
Published
2008-01
Volume
19
Issue
8
Pages
1073-1085
ISSN
  • 0920-5063 (ISSN-L)
  • 1568-5624
OpenAlex
W2002793051
Cited by
51
References
2
FWCI
3.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Application of an elastic biodegradable poly(L-lactide-co-ε-caprolactone) scaffold for cartilage tissue regeneration. https://app.cochat.ai/papers/10.1163/156856208784909336
The paper
Jung, Y., Kim, S. H., You, H. J., Kim, S.-H., Ha Kim, Y., & Min, B. G. (2008). Application of an elastic biodegradable poly(L-lactide-co-ε-caprolactone) scaffold for cartilage tissue regeneration. Journal of Biomaterials Science, Polymer Edition. https://doi.org/10.1163/156856208784909336

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.