Comparison of assisted ventilator modes on triggering, patient effort, and dyspnea.
The DOI matches its Crossref record.
Abstract
In 11 ventilator-dependent patients, we undertook a head-to-head comparison of patient-ventilator interaction during four ventilator modes: assist-control ventilation (ACV), intermittent mandatory ventilation (IMV), pressure support (PS), and a combination of IMV and PS. Progressive increases in IMV rate and PS level each decreased inspiratory pressure-time product (PTP) (p < 0.0001). These reductions in PTP were greater with PS than with IMV at lower but proportional levels of maximal assistance (p < 0.005). When PS 10 cm H2O was added to a given level of IMV, greater reductions in PTP were achieved not only during intervening (PS) breaths (p < 0.001), but also during mandatory (volume-assisted) breaths (p < 0.0005); this additional unloading during mandatory breaths was proportional to the decrease in respiratory drive (dP/dt) during intervening breaths (r = 0.67, p < 0.0001). Maximal unloading occurred with ACV, achieving more than a fivefold decrease in PTP compared with unassisted breathing. Decreases in PTP were confined to the post-trigger phase, and PTP of the post-trigger phase correlated with dP/dt (r = 0.78, p < 0.0001). Effort during the trigger phase remained constant despite marked changes in drive and intrinsic positive end-expiratory pressure (PEEPi). Ineffective triggering occurred with all modes, and wasted PTP increased with increasing levels of assistance as a result of the accompanying decrease in drive and increase in volume. Breaths preceding nontriggering efforts had shorter respiratory cycle times (p < 0.0005) and expiratory times (p < 0.0001) and higher PEEPi (p < 0.0001), indicating that neural-mechanical asynchrony resulted from inspiratory activity commencing prematurely before elastic recoil pressure had fallen to a level that could be overcome by a patient's muscular effort. Thus, increases in the level of ventilator assistance produced progressive decreases in inspiratory muscle effort and dyspnea,which were accompanied by increases in the rate of ineffective triggering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS/ERS Statement on Respiratory Muscle Testing
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.166.4.518 · Cited by 2,841
Weaning from mechanical ventilation
Boles, J.-M., Bion, J., Connors, A., Herridge, M., Marsh, B., Melot, C., Pearl, R., Silverman, H., Stanchina, M., Vieillard-Baron, A., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00010206 · Cited by 2,064
Patient-ventilator asynchrony during assisted mechanical ventilation
Thille, A. W., Rodriguez, P., Cabello, B., Lellouche, F., & Brochard, L. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0301-8 · Cited by 930
ESTEBAN, A., ANZUETO, A., ALÍA, I., GORDO, F., APEZTEGUÍA, C., PÁLIZAS, F., CIDE, D., GOLDWASER, R., SOTO, L., BUGEDO, G., et al. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.5.9902018 · Cited by 780
Self-citationNon-invasive ventilation in acute respiratory failure
(2002) · Thorax · doi:10.1136/thorax.57.3.192 · Cited by 652
Neural control of mechanical ventilation in respiratory failure
Sinderby, C., Navalesi, P., Beck, J., Skrobik, Y., Comtois, N., Friberg, S., Gottfried, S. B., & Lindström, L. (1999) · Nature Medicine · doi:10.1038/71012 · Cited by 636
The Application of Esophageal Pressure Measurement in Patients with Respiratory Failure
Akoumianaki, E., Maggiore, S. M., Valenza, F., Bellani, G., Jubran, A., Loring, S. H., Pelosi, P., Talmor, D., Grasso, S., Chiumello, D., et al. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201312-2193ci · Cited by 635
Self-citationAdvances in Mechanical Ventilation
Tobin, M. J. (2001) · New England Journal of Medicine · doi:10.1056/nejm200106283442606 · Cited by 475
Self-citationVignaux, L., Vargas, F., Roeseler, J., Tassaux, D., Thille, A. W., Kossowsky, M. P., Brochard, L., & Jolliet, P. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1416-5 · Cited by 353
Changes in the Work of Breathing Induced by Tracheotomy in Ventilator-dependent Patients
DIEHL, J.-L., EL ATROUS, S., TOUCHARD, D., LEMAIRE, F., & BROCHARD, L. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.2.9707046 · Cited by 330
Thille, A. W., Cabello, B., Galia, F., Lyazidi, A., & Brochard, L. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1121-9 · Cited by 288
Cycling of Inspiratory and Expiratory Muscle Groups with the Ventilator in Airflow Limitation
PARTHASARATHY, S., JUBRAN, A., & TOBIN, M. J. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.5.9802014 · Cited by 233
Self-citationColombo, D., Cammarota, G., Bergamaschi, V., De Lucia, M., Corte, F. D., & Navalesi, P. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1208-3 · Cited by 225
“worsen patient–ventilator interaction [7, 10, 11].”
Spahija, J., de Marchie, M., Albert, M., Bellemare, P., Delisle, S., Beck, J., & Sinderby, C. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181cb0d7b · Cited by 211
BECK, J., GOTTFRIED, S. B., NAVALESI, P., SKROBIK, Y., COMTOIS, N., ROSSINI, M., & SINDERBY, C. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.3.2009018 · Cited by 203
Observational study of patient-ventilator asynchrony and relationship to sedation level
de Wit, M., Pedram, S., Best, A. M., & Epstein, S. K. (2009) · Journal of Critical Care · doi:10.1016/j.jcrc.2008.08.011 · Cited by 199
“(5,7) Therefore, we may not have had the power to detect COPD as a marker of ineffective triggering.”
BackgroundResultInfluentialImpact of Expiratory Trigger Setting on Delayed Cycling and Inspiratory Muscle Workload
Tassaux, D., Gainnier, M., Battisti, A., & Jolliet, P. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200407-880oc · Cited by 196
“These findings differ from those of Leung and colleagues (12), who documented higher levels of inspiratory efforts during such breaths.”
BackgroundResultInfluentialTitration and Implementation of Neurally Adjusted Ventilatory Assist in Critically Ill Patients
Brander, L., Leong-Poi, H., Beck, J., Brunet, F., Hutchison, S. J., Slutsky, A. S., & Sinderby, C. (2009) · Chest · doi:10.1378/chest.08-1747 · Cited by 171
Clinical review: Respiratory monitoring in the ICU - a consensus of 16
Brochard, L., Martin, G. S., Blanch, L., Pelosi, P., Belda, F. J., Jubran, A., Gattinoni, L., Mancebo, J., Ranieri, V. M., Richard, J.-C. M., et al. (2012) · Critical Care · doi:10.1186/cc11146 · Cited by 160
“Excessive levels of pressure support may result in ineff ective triggering because they are associated with long inspiratory times and intrinsic PEEP [54], and insuffi cient assistance (for example, because of a short inspiratory time during assist/control ventilation) can also result in dyssynchrony.”
BackgroundSelf-citationAdler, D., Perrig, S., Takahashi, H., Espa, F., Rodenstein, D., Pépin, J. L., & Janssens, J.-P. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0605-y · Cited by 104
“In selected subjects with severe COPD and static hyperinflation, excessive pressure support might lead to dynamic hyperinflation and increased PEEPi [31] which are major determinants of unrewarded efforts [21].”
Background
Metadata
- Authors
- Leung, P., Jubran, A., & Tobin, M. J.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-06
- Volume
- 155
- Issue
- 6
- Pages
- 1940-1948
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2005270749
- Cited by
- 420
- References
- 0
- FWCI
- 10.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.