Tidal Volume Reduction for Prevention of Ventilator-induced Lung Injury in Acute Respiratory Distress Syndrome
The DOI matches its Crossref record, with a small difference in title or year; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Because animal studies have demonstrated that mechanical ventilation at high volume and pressure can be deleterious to the lungs, limitation of airway pressure, allowing hypercapnia if necessary, is already used for ventilation of acute respiratory distress syndrome (ARDS). Whether a systematic and more drastic reduction is necessary is debatable. A multicenter randomized study was undertaken to compare a strategy aimed at limiting the end-inspiratory plateau pressure to 25 cm H2O, using tidal volume (Vt) below 10 ml/kg of body weight, versus a more conventional ventilatory approach (with regard to current practice) using Vt at 10 ml/kg or above and close to normal PaCO2. Both arms used a similar level of positive end-expiratory pressure. A total of 116 patients with ARDS and no organ failure other than the lung were enrolled over 32 mo in 25 centers. The two groups were similar at inclusion. Patients in the two arms were ventilated with different Vt (7.1 ± 1.3 versus 10.3 ± 1.7 ml/kg at Day 1, p < 0.001) and plateau pressures (25.7 ± 5.0 versus 31.7 ± 6.6 cm H2O at Day 1, p < 0.001), resulting in different PaCO2 (59.5 ± 15.0 versus 41.3 ± 7.6 mm Hg, p < 0.001) and pH (7.28 ± 0.09 versus 7.4 ± 0.09, p < 0.001), but a similar level of oxygenation. The new approach did not reduce mortality at Day 60 (46.6% versus 37.9% in control subjects, p = 0.38), the duration of mechanical ventilation (23.1 ± 20.2 versus 21.4 ± 16.3 d, p = 0.85), the incidence of pneumothorax (14% versus 12%, p = 0.78), or the secondary occurrence of multiple organ failure (41% versus 41%, p = 1). We conclude that no benefit could be observed with reduced Vt titrated to reach plateau pressures around 25 cm H2O compared with a more conventional approach in which normocapnia was achieved with plateau pressures already below 35 cm H2O.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Although the β-1 activity of dopamine may be useful in patients with myocardial dysfunction, the higher risk of arrhythmias limits its use (348).”
From Surviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock 2021. (2021) · cites this paper as [348]
In the citing paper
“Several multicentre RCTs have been performed in patients with established ARDS to evaluate the effects of limiting inspiratory pressure through moderation of tidal volume [424–427].”
From Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021 (2021) · cites this paper as [426]
In the citing paper
“These three RCTS compared a strategy of low tidal volume and limited plateau pressure with a strategy using higher tidal volume and plateau pressure; pooled data suggest reduced mortality (RR 0.83; 95% CI 0.70–0.97) and more ventilator-free days (MD 1.8 days; 95% CI 0.35–3.25) in patients managed with low plateau pressures.”
From Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021 (2021) · cites this paper as [426]
In the citing paper
“Of note, the 3 RCTs that guide this recommendation [424, 426, 427] enrolled patients using the criteria from the American-European Consensus Criteria Definition for Acute Lung Injury and ARDS [422] whereas the current document use the 2012 Berlin definition and the terms mild, moderate, and severe ARDS (PaO2/FiO2 ≤ 300, ≤ 200, and ≤ 100 mm Hg, respectively) [423].”
From Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021 (2021) · cites this paper as [426]
Citations
Cites
APACHE II: A severity of disease classification system
KNAUS, W. A., DRAPER, E. A., WAGNER, D. P., & ZIMMERMAN, J. E. (1985) · Critical Care Medicine · doi:10.1097/00003246-198510000-00009 · Cited by 13,664 · cited 1×
“No. of patients (M/F) 58 (33/25) 58 (33/25) 1 Age, yr 57.0 6 15.3 56.5 6 15.3 0.85 APACHE II ( 27 )”
InfluentialAPACHE II-A Severity of Disease Classification System: Reply
Knaus, W. A., Draper, E. A., Wagner, D. P., & Zimmerman, J. E. (1986) · Critical Care Medicine · doi:10.1097/00003246-198608000-00028 · Cited by 13,376
Le Gall, J.-R. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.270.24.2957 · Cited by 7,773 · cited 2×
“On admission 19 6 9 17 6 7 0.12 At inclusion 18 6 7 17 6 8 0.30 SAPS II ( 23 )”
MethodInfluentialBernard, G. R., Artigas, A., Brigham, K. L., Carlet, J., Falke, K., Hudson, L., Lamy, M., Legall, J. R., Morris, A., & Spragg, R. (1994) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.149.3.7509706 · Cited by 6,746
Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome.
Amato, M. B. P., Barbas, C. S. V., Medeiros, D. M., Magaldi, R. B., Schettino, G. P., Lorenzi-Filho, G., Kairalla, R. A., Deheinzelin, D., Munoz, C., Oliveira, R., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802053380602 · Cited by 3,654
An Expanded Definition of the Adult Respiratory Distress Syndrome
Murray, J. F., Matthay, M. A., Luce, J. M., & Flick, M. R. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/138.3.720 · Cited by 2,646 · cited 3×
“Lung Injury Score ( 18 ) 3.0 6 0.3 3.0 6 0.3 0.57 Pa O2 /F IO2 , mm Hg 144 6 61 155 6 68 0.54”
BackgroundMethodInfluentialTidal ventilation at low airway pressures can augment lung injury.
Muscedere, J. G., Mullen, J. B., Gan, K., & Slutsky, A. S. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.5.8173774 · Cited by 1,244
Prognosis in Acute Organ-System Failure
KNAUS, W. A., DRAPER, E. A., WAGNER, D. P., & ZIMMERMAN, J. E. (1985) · Annals of Surgery · doi:10.1097/00000658-198512000-00004 · Cited by 1,225 · cited 4×
“In addition to recordings of arterial blood gases (recorded once a day) and ventilator settings, APACHE II (19) and Simplified Acute Physiology Score (SAPS) II (23) were calculated both on admission to the intensive care unit and on inclusion in the study; the number of organ systems failing were calculated on Days 1,…”
BackgroundMethodInfluentialHh, W., & Tierney, D. F. (1974) · PubMed · doi:10.1164/arrd.1974.110.5.556 · Cited by 941
Hickling, K. G., Henderson, S. J., & Jackson, R. (1990) · Intensive Care Medicine · doi:10.1007/bf01735174 · Cited by 933
Gattinoni, L., Pesenti, A., Avalli, L., Rossi, F., & Bombino, M. (1987) · American Review of Respiratory Disease · doi:10.1164/ajrccm/136.3.730 · Cited by 900
Hickling, K. G., Walsh, J., Henderson, S., & Jackson, R. (1994) · Critical Care Medicine · doi:10.1097/00003246-199422100-00011 · Cited by 695
Pepe, P., & Marini, J. J. (1982) · PubMed · doi:10.1164/arrd.1982.126.1.166 · Cited by 672
Amato, M. B., Barbas, C. S., Medeiros, D. M., Schettino, G. D. P., Lorenzi Filho, G., Kairalla, R. A., Deheinzelin, D., Morais, C., Fernandes, E. D. O., & Takagaki, T. Y. (1995) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.152.6.8520744 · Cited by 625
Gattinoni, L., Pelosi, P., Crotti, S., & Valenza, F. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.151.6.7767524 · Cited by 582
(1987) · Journal of Critical Care · doi:10.1016/0883-9441(87)90024-4 · Cited by 572
The Acute Respiratory Distress Syndrome
Kollef, M. H., & Schuster, D. P. (1995) · New England Journal of Medicine · doi:10.1056/nejm199501053320106 · Cited by 550 · cited 3×
“While tidal volumes of 15 ml/kg or higher were frequently employed several years ago ( 31 ), this approach was no longer considered acceptable at the time we designed our study (1, 31).”
BackgroundMethodInfluentialDreyfuss, D., & Saumon, G. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/148.5.1194 · Cited by 514
Self-citationPermissive hypercapnia. How permissive should we be?
Feihl, F., & Perret, C. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.6.7952641 · Cited by 437
Kolobow, T., Moretti, M. P., Fumagalli, R., MASCHERONI, D., Prato, P., Chen, V., & Joris, M. (1987) · PubMed · doi:10.1164/arrd.1987.135.2.312 · Cited by 435
Acute lung injury from mechanical ventilation at moderately high airway pressures
Tsuno, K., Prato, P., & Kolobow, T. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.69.3.956 · Cited by 347
Adverse Effects of Large Tidal Volume and Low PEEP in Canine Acid Aspiration
Corbridge, T. C., Wood, L. D. H., Crawford, G. P., Chudoba, M. J., Yanos, J., & Sznajder, J. I. (1990) · American Review of Respiratory Disease · doi:10.1164/ajrccm/142.2.311 · Cited by 339
Titration of tidal volume and induced hypercapnia in acute respiratory distress syndrome.
Roupie, E., Dambrosio, M., Servillo, G., Mentec, H., el Atrous, S., Beydon, L., Brun-Buisson, C., Lemaire, F., & Brochard, L. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.1.7599810 · Cited by 327
Self-citationMechanical ventilation-induced pulmonary edema. Interaction with previous lung alterations.
Dreyfuss, D., Soler, P., & Saumon, G. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.151.5.7735616 · Cited by 231
Self-citationHistologic aspects of pulmonary barotrauma in critically ill patients with acute respiratory failure
Rouby, J. J., Lherm, T., Martin de Lassale, E., Poète, P., Bodin, L., Finet, J. F., Callard, P., & Viars, P. (1993) · Intensive Care Medicine · doi:10.1007/bf01724877 · Cited by 211
Puybasset, L., Stewart, T., Rouby, J.-J., Cluzel, P., Mourgeon, E., Belin, M.-F., Arthaud, M., Landault, C., & Wars, P. (1994) · Anesthesiology · doi:10.1097/00000542-199406000-00013 · Cited by 203 · cited 2×
“The level of positive end-expiratory pressure may be especially important in this situation, as shown by experimental (38, 39 ) and human data (43).”
BackgroundConsensus conference on mechanical ventilation-January 28–30, 1993 at Northbrook, Illinois, USA
Slutsky, A. S. (1994) · Intensive Care Medicine · doi:10.1007/bf01707673 · Cited by 193
Ranieri, V. M., Mascia, L., Fiore, T., Bruno, F., BRIENZA, A., & Giuliani, R. (1995) · Anesthesiology · doi:10.1097/00000542-199510000-00010 · Cited by 142 · cited 1×
“The level of positive end-expiratory pressure may be especially important in this situation, as shown by experimental (38, 39) and human data ( 43 ).”
BackgroundDAMBROSIO, M., Roupie, É., Mollet, J.-J., Anglade, M., VASILE, N., Lemaire, F., & Brochard, L. J. (1997) · Anesthesiology · doi:10.1097/00000542-199709000-00007 · Cited by 138
Self-citationThorens, J.-B., Jolliet, P., Ritz, M., & Chevrolet, J.-C. (1996) · Intensive Care Medicine · doi:10.1007/bf01712235 · Cited by 132
Mechanical ventilation increases microvascular permeability in oleic acid-injured lungs
Hernandez, L. A., COKER, P. J., May, S., Thompson, A. L., & Parker, J. C. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.69.6.2057 · Cited by 130
Clinical Risk Factors for Pulmonary Barotrauma: A Multivariate Analysis
Gammon, R. B., Shin, M. S., Groves, R. H., Hardin, J. M., Hsu, C.-W., & Buchalter, S. E. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.4.7551376 · Cited by 122
Systemic Gas Embolism Complicating Mechanical Ventilation in the Adult Respiratory Distress Syndrome
Marini, J. J., & Culver, B. H. (1989) · Annals of Internal Medicine · doi:10.7326/0003-4819-110-9-699 · Cited by 107
Benito, S., & Lemaire, F. (1990) · Journal of Critical Care · doi:10.1016/0883-9441(90)90006-u · Cited by 98
Self-citationCereda, M. F., Foti, G., Musch, G., Sparacino, M. E., & Pesenti, A. M. (1996) · CHEST Journal · doi:10.1378/chest.109.2.480 · Cited by 73 · cited 2×
“The level of positive end-expiratory pressure may be especially important in this situation, as shown by experimental ( 38 , 39) and human data (43).”
BackgroundShould Mechanical Ventilation Be Optimized to Blood Gases, Lung Mechanics, or Thoracic CT Scan?
Brunet, F. P., Jeanbourquin, D., Monchi, M., Mira, J. P., Fierobe, L., Armaganidis, A., Renaud, B., Belghith, M., Nouira, S., & Dhainaut, J.-F. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.2.7633702 · Cited by 65
Increased sensitivity to mechanical ventilation after surfactant inactivation in young rabbit lungs
COKER, P. J., Hernandez, L. A., Peevy, K. J., Adkins, K., & Parker, J. C. (1992) · Critical Care Medicine · doi:10.1097/00003246-199205000-00015 · Cited by 55
Extracorporeal Carbon Dioxide Removal Technique Improves Oxygenation Without Causing Overinflation
Brunet, F. P., Mira, J. P., Belghith, M., Monchi, M., Renaud, B., Fierobe, L., Hamy, I., Dhainaut, J.-F., & DALL'AVA-SANTUCCI, J. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.6.8004313 · Cited by 53
PEEP-Induced Airspace Overdistension Complicating Paraquat Lung
Lemaire, F., Cerrina, J., Lange, F., HARF, A., Carlet, J. M., & Bignon, J. (1982) · CHEST Journal · doi:10.1378/chest.81.5.654 · Cited by 12 · cited 1×
“In addition to evidence from animal studies, this hypothesis has been supported indirectly by the presence of cysts, bullae, or emphysematous-like lesions at autopsy of such patients (21, 22, 28 , 29).”
BackgroundSelf-citation
Research works printed but not linked: 2
- Webb, 1974, Experimental pulmonary edema due to intermittent positive end-expiratory pressures., Am. Rev. Respir. Dis., 110, 556
- Amato, 1996, Improved survival in ARDS: beneficial effects of a lung protective strategy (abstract)., Am. J. Respir. Crit. Care Med., 153, A531
Cited by
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
The Surviving Sepsis Campaign Guidelines Committee including The Pediatric Subgroup*, Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2769-8 · Cited by 7,290
Dellinger, R. P., Levy, M. M., Carlet, J. M., Bion, J., Parker, M. M., Jaeschke, R., Reinhart, K., Angus, D. C., Brun-Buisson, C., Beale, R., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-007-0934-2 · Cited by 6,772
Self-citationSurviving Sepsis Campaign: International guidelines for management of sepsis and septic shock: 2016.
Rhodes, A., Evans, L. E., Alhazzani, W., Levy, M. M., Antonelli, M., Ferrer, R., Kumar, A., Sevransky, J. E., Sprung, C. L., Nunnally, M. E., et al. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4683-6 · Cited by 6,621
Metadata
- Authors
- BROCHARD, L., ROUDOT-THORAVAL, F., ROUPIE, E., DELCLAUX, C., CHASTRE, J., FERNANDEZ-MONDÉJAR, E., CLÉMENTI, E., MANCEBO, J., FACTOR, P., MATAMIS, D., RANIERI, M., BLANCH, L., RODI, G., MENTEC, H., DREYFUSS, D., FERRER, M., BRUN-BUISSON, C., TOBIN, M., & LEMAIRE, F.
- Affiliations
- Inserm (FR)
- Medical Intensive Care Unit, Henri Mondor Hospital, Assistance Publique–Hôpitaux de Paris, Université Paris XII and INSERM U 492, Créteil, France
- ORCID
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-12-01
- Volume
- 158
- Issue
- 6
- Pages
- 1831-1838
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2147279870
- Semantic Scholar
- cb70286353a7786eaafef9f7504089fce0923031
- Cited by
- 800
- References
- 39
- Citations by year
- 2026: 7 · 2025: 5 · 2024: 7 · 2023: 8 · 2022: 30 · 2021: 18 · 2020: 14 · 2019: 21 · 2018: 15 · 2017: 24 · 2016: 17 · 2015: 22 · 2014: 27 · 2013: 35 · 2012: 30
- FWCI
- 32.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Respiratory and Critical Care Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Neonatal Respiratory Health Research
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Nosocomial Infections in ICU
- Keywords
- acute respiratory distress syndrome, ventilator-induced lung injury, tidal volume reduction, plateau pressure, mechanical ventilation, hypercapnia, positive end-expiratory pressure, mortality, multiple organ failure, pneumothorax, lung-protective ventilation, normocapnia, oxygenation, acid-base balance, mechanical ventilation duration, randomized controlled trials
- MeSH terms
- Adolescent, Adult, Aged, Body Weight, Carbon Dioxide, Humans, Hydrogen-Ion Concentration, Hypercapnia, Inspiratory Capacity, Lung Diseases, Middle Aged, Multiple Organ Failure, Oxygen, Oxygen Consumption, Pneumothorax, Positive-Pressure Respiration, Pressure, Respiration, Artificial, Pulmonary Ventilation, Respiratory Distress Syndrome, Tidal Volume, Time Factors, Incidence, Survival Rate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.