Physiologic Determinants of Ventilator Dependence in Long-term Mechanically Ventilated Patients
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
To investigate the pathophysiologic mechanisms of ventilator dependence, we took physiologic measurements in 28 patients with COPD and 11 postcardiac surgery (PCS) patients receiving long-term mechanical ventilation during a spontaneous breathing trial, and in 20 stable, spontaneously breathing patients matched for age and disease. After 40 +/- 14 min of spontaneous breathing, 20 of 28 patients with COPD and all 11 PCS patients were judged ventilator-dependent (VD). We found that in the 31 VD patients tidal volume was low (VT: 0.36 +/- 0.12 and 0.31 +/- 0.08 L for COPD and PCS, respectively), neuromuscular drive was high (P(0.1): 5.6 +/- 1. 6 and 3.9 +/- 1.9 cm H(2)O), inspiratory muscle strength was reduced (Pdi(max): 42 +/- 12 and 28 +/- 15 cm H(2)O), and lung mechanics were abnormal, particularly PEEPi (5.9 +/- 3.0 cm H(2)O) and lung resistance (22.2 +/- 9.2 cm H(2)O/L/s) in COPD. The load/capacity balance was altered (Pdi/Pdi(max) and Ppl/Ppl(max) > 0.4) and the effective inspiratory impedance was high (P(0.1)/VT/TI >/= 10 cm H(2)O/L/s). Failure to wean occurred in patients with f/VT > 105 breaths/min/L and 56% of patients with COPD with f/VT < 80 breaths/min/L. Those who failed despite a low f/VT ( < 80 breaths/min/L) either showed ineffective inspiratory efforts, which artificially lowered f/ VT (n = 8), or did not increase breathing frequency (n = 5), but P(0.1) and P(0.1)/VT/TI were as high as in other VD patients. In the 31 VD patients, Pa(CO(2)) increased during the weaning trial (+12.3 +/- 8.0 mm Hg). We conclude that in the presence of a high drive to breathe, the imbalance between increased work load and reduced inspiratory muscle strength causes respiratory distress and CO(2) retention. Noninvasive measurements (breathing pattern, P(0.1), P(0.1)/ VT/TI) may give better insight into weaning failure useful in clinical decision-making, particularly in patients with COPD not showing rapid shallow breathing (56% in this study).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Siafakas, N., Vermeire, P., Pride, N., Paoletti, P., Gibson, J., Howard, P., Yernault, J., Decramer, M., Higenbottam, T., Postma, D., et al. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08081398 · Cited by 1,592 · cited 1×
“As soon as the patient was accustomed to the experimental setting and equipment, arterial blood was sampled from the radial artery to measure Pa O 2 , Pa CO 2 , and pH. Then the weaning trial started, and the patient was disconnected from the ventilator and left to breathe spontaneously while receiving supplemental ox…”
MethodYang, K. L., & Tobin, M. J. (1991) · New England Journal of Medicine · doi:10.1056/nejm199105233242101 · Cited by 1,378
Ely, E. W., Baker, A. M., Dunagan, D. P., Burke, H. L., Smith, A. C., Kelly, P. T., Johnson, M. M., Browder, R. W., Bowton, D. L., & Haponik, E. F. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612193352502 · Cited by 1,346 · cited 3×
“Similarly to some studies on large heterogeneous ICU populations (3, 5 , 6, 30), a high f/VT ratio . 100 can predict weaning failure also in the chronic care setting.”
BackgroundInfluentialA simple method for assessing the validity of the esophageal balloon technique.
Baydur, A., BEHRAKIS, P. K., Zin, W. A., Jaeger, M., & Milic‐Emili, J. (1982) · PubMed · doi:10.1164/arrd.1982.126.5.788 · Cited by 1,076
Esley, E. W., Ly, E., Aker, M., Unagan, D. O. P. D., Urke, L. B., Mith, C. S., Atrick, P., Elly, T. K., Argaret, M., Ohnson, M. J., et al. (1996) · Cited by 950
ESTEBAN, A., ALÍA, I., TOBIN, M. J., GIL, A., GORDO, F., VALLVERDÚ, I., BLANCH, L., BONET, A., VÁZQUEZ, A., de PABLO, R., et al. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.2.9803106 · Cited by 773 · cited 6×
“The circuit included the pneumotachograph, connectors with the side port to sample Pao, and a T-tube (4).”
BackgroundInfluentialEffect of pressure and timing of contraction on human diaphragm fatigue
Bellemare, F., & Grassino, A. (1982) · Journal of Applied Physiology · doi:10.1152/jappl.1982.53.5.1190 · Cited by 644 · cited 4×
“A series of studies in normal subjects (13) and in patients with stable COPD (14) have suggested that a TTdi .”
BackgroundMethodResultInfluentialAppendini, L., Patessio, A., Zanaboni, S., Carone, M., Gukov, B., Donner, C. F., & Rossi, A. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.5.8173743 · Cited by 515 · cited 4×
“Dynamic intrinsic positive end-expiratory pressure (PEEPi dyn ) was estimated from the decrease in Ppl preceding the start of the inspiratory flow with correction for expiratory muscle activity by subtraction of the negative deflection in Pab (7, 10).”
MethodInfluentialSelf-citationRoussos, C. S., & Macklem, P. T. (1977) · Journal of Applied Physiology · doi:10.1152/jappl.1977.43.2.189 · Cited by 497 · cited 2×
“4 was associated with the incapability to sustain spontaneous breathing for long (20).”
BackgroundVALLVERDÚ, I., CALAF, N., SUBIRANA, M., NET, A., BENITO, S., & MANCEBO, J. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.6.9712135 · Cited by 480 · cited 5×
“On the one hand, similar to what has been reported for ICU patients (6), a high f/VT ratio, e.”
BackgroundResultInfluential
Cited by
Vestbo, J., Hurd, S. S., Agustí, A. G., Jones, P. W., Vogelmeier, C., Anzueto, A., Barnes, P. J., Fabbri, L. M., Martinez, F. J., Nishimura, M., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201204-0596pp · Cited by 15,983
Disorders of the Respiratory Muscles
Laghi, F., & Tobin, M. J. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2206020 · Cited by 687
Management of Patients Requiring Prolonged Mechanical Ventilation
MacIntyre, N. R., Epstein, S. K., Carson, S., Scheinhorn, D., Christopher, K., & Muldoon, S. (2005) · Chest · doi:10.1378/chest.128.6.3937 · Cited by 533
McKenzie, D. K., & Frith, P. A. (2003) · Medical Journal of Australia · doi:10.5694/j.1326-5377.2003.tb05213.x · Cited by 369
Is Weaning Failure Caused by Low-Frequency Fatigue of the Diaphragm?
Laghi, F., Cattapan, S. E., Jubran, A., Parthasarathy, S., Warshawsky, P., Choi, Y.-S. A., & Tobin, M. J. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200210-1246oc · Cited by 359
Martin, A. D., Smith, B. K., Davenport, P. D., Harman, E., Gonzalez-Rothi, R. J., Baz, M., Layon, A. J., Banner, M. J., Caruso, L. J., Deoghare, H., et al. (2011) · Critical Care · doi:10.1186/cc10081 · Cited by 294
Ineffective triggering predicts increased duration of mechanical ventilation *
de Wit, M., Miller, K. B., Green, D. A., Ostman, H. E., Gennings, C., & Epstein, S. K. (2009) · Critical Care Medicine · doi:10.1097/00003246-200910000-00010 · Cited by 286
Prolonged mechanical ventilation alters diaphragmatic structure and function
Powers, S. K., Kavazis, A. N., & Levine, S. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181b6e760 · Cited by 203
“Furthermore, patients who fail to wean from the ventilator have significantly weaker inspiratory muscles compared with patients who can be weaned from MV (9).”
BackgroundObservational study of patient-ventilator asynchrony and relationship to sedation level
de Wit, M., Pedram, S., Best, A. M., & Epstein, S. K. (2009) · Journal of Critical Care · doi:10.1016/j.jcrc.2008.08.011 · Cited by 199
“Patients with COPD and those with intrinsic PEEP resulting from hyperinflation are more likely to demonstrate ineffective triggering.(1,2,3,4,5,7,18) Although we did not measure intrinsic PEEP in our pilot study, we found no correlation between plateau pressure and ineffective triggering.”
BackgroundClusters of ineffective efforts during mechanical ventilation: impact on outcome
Vaporidi, K., Babalis, D., Chytas, A., Lilitsis, E., Kondili, E., Amargianitakis, V., Chouvarda, I., Maglaveras, N., & Georgopoulos, D. (2017) · Intensive Care Medicine · doi:10.1007/s00134-016-4593-z · Cited by 184
VITACCA, M., VIANELLO, A., COLOMBO, D., CLINI, E., PORTA, R., BIANCHI, L., ARCARO, G., VITALE, G., GUFFANTI, E., LO COCO, A., et al. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.2.2008160 · Cited by 177
Mechanisms, assessment and therapeutic implications of lung hyperinflation in COPD
Rossi, A., Aisanov, Z., Avdeev, S., Di Maria, G., Donner, C. F., Izquierdo, J. L., Roche, N., Similowski, T., Watz, H., Worth, H., et al. (2015) · Respiratory Medicine · doi:10.1016/j.rmed.2015.03.010 · Cited by 121
Self-citation
Metadata
- Authors
- PURRO, A., APPENDINI, L., DE GAETANO, A., GUDJONSDOTTIR, M., DONNER, C. F., & ROSSI, A.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-04-01
- Volume
- 161
- Issue
- 4
- Pages
- 1115-1123
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W1981332436
- Cited by
- 189
- References
- 29
- FWCI
- 8.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.