Best Compliance during a Decremental, But Not Incremental, Positive End-Expiratory Pressure Trial Is Related to Open-Lung Positive End-Expiratory Pressure: A Mathematical Model of Acute Respiratory Distress Syndrome Lungs
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
A mathematical model of the acute respiratory distress syndrome (ARDS) lung, incorporating simulated gravitational superimposed pressure and alveolar opening and closing pressures, was used to study the mean tidal pressure-volume (PV) slope ("effective compliance") during incremental and decremental positive end-expiratory pressure (PEEP) trials with constant tidal volume (VT) "ventilation." During incremental PEEP, the PEEP giving maximum mean tidal PV slope did not coincide with "open lung PEEP" (minimum PEEP preventing end expiratory collapse of 97.5% of alveoli inflated at end-inspiration), and it varied greatly with varying VT and "lung mechanics." Incremental PEEP with a low VT tests recruitment by the peak pressure, not prevention of collapse by PEEP. During decremental PEEP with a low VT, maximum mean tidal PV slope occurred with PEEP 2-3.5 cm H2O below open-lung PEEP, unless closing pressure was high. High VT, high "specific compliance," and high opening pressures caused slightly greater underestimation of open-lung PEEP. Maximum mean tidal PV slope was always higher (e.g., 93.7 versus 16.69 ml/cm H2O), and the variation in PV slope with PEEP was greater, during decremental PEEP. The maximum PV slope during a decremental PEEP trial with a low VT may be a useful method to determine open-lung PEEP in ARDS, and should be studied clinically.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome.
Amato, M. B. P., Barbas, C. S. V., Medeiros, D. M., Magaldi, R. B., Schettino, G. P., Lorenzi-Filho, G., Kairalla, R. A., Deheinzelin, D., Munoz, C., Oliveira, R., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802053380602 · Cited by 3,654
Ranieri, V. M., Suter, P. M., Tortorella, C., De Tullio, R., Dayer, J. M., Brienza, A., Bruno, F., & Slutsky, A. S. (1999) · JAMA · doi:10.1001/jama.282.1.54 · Cited by 1,908
Tremblay, L., Valenza, F., Ribeiro, S. P., Li, J., & Slutsky, A. S. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119259 · Cited by 1,330
Optimum End-Expiratory Airway Pressure in Patients with Acute Pulmonary Failure
Suter, P. M., Fairley, H. B., & Isenberg, M. D. (1975) · New England Journal of Medicine · doi:10.1056/nejm197502062920604 · Cited by 1,295
Tidal ventilation at low airway pressures can augment lung injury.
Muscedere, J. G., Mullen, J. B., Gan, K., & Slutsky, A. S. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.5.8173774 · Cited by 1,244
Gattinoni, L., Pesenti, A., Avalli, L., Rossi, F., & Bombino, M. (1987) · American Review of Respiratory Disease · doi:10.1164/ajrccm/136.3.730 · Cited by 900
Multiple System Organ Failure: Is Mechanical Ventilation a Contributing Factor?
SLUTSKY, A. S., & TREMBLAY, L. N. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.6.9709092 · Cited by 836
Amato, M. B., Barbas, C. S., Medeiros, D. M., Schettino, G. D. P., Lorenzi Filho, G., Kairalla, R. A., Deheinzelin, D., Morais, C., Fernandes, E. D. O., & Takagaki, T. Y. (1995) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.152.6.8520744 · Cited by 625
Gattinoni, L., Pelosi, P., Crotti, S., & Valenza, F. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.151.6.7767524 · Cited by 582
Gattinoni, L. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1993.03500160092039 · Cited by 481
RE-EXPANSION OF ATELECTASIS DURING GENERAL ANAESTHESIA: A COMPUTED TOMOGRAPHY STUDY
ROTHEN, H. U., SPORRE, B., ENGBERG, G., WEGENIUS, G., & HEDENSTIERNA, G. (1993) · British Journal of Anaesthesia · doi:10.1093/bja/71.6.788 · Cited by 425
The Pressure–Volume Curve Is Greatly Modified by Recruitment: A Mathematical Model of ARDS Lungs
HICKLING, K. G. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.1.9708049 · Cited by 412
Self-citationJONSON, B., RICHARD, J.-C., STRAUS, C., MANCEBO, J., LEMAIRE, F., & BROCHARD, L. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.4.9801088 · Cited by 385
RANIERI, V. M., SUTER, P. M., TORTORELLA, C., TULLIO, R. D., DAYER, J. M., BRIENZA, A., BRUNO, F., & SLUTSKY, A. S. (2000) · Survey of Anesthesiology · doi:10.1097/00132586-200002000-00011 · Cited by 286
Effect of granulocyte depletion in a ventilated surfactant-depleted lung
Kawano, T., Mori, S., Cybulsky, M., Burger, R., Ballin, A., Cutz, E., & Bryan, A. C. (1987) · Journal of Applied Physiology · doi:10.1152/jappl.1987.62.1.27 · Cited by 275
Ventilator pattern influences neutrophil influx and activation in atelectasis-prone rabbit lung
Sugiura, M., McCulloch, P. R., Wren, S., Dawson, R. H., & Froese, A. B. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.3.1355 · Cited by 170
Mergoni, M., Martelli, A., Volpi, A., Primavera, S., Zuccoli, P., & Rossi, A. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.3.9607040 · Cited by 162
Ranieri, V. M., Mascia, L., Fiore, T., Bruno, F., BRIENZA, A., & Giuliani, R. (1995) · Anesthesiology · doi:10.1097/00000542-199510000-00010 · Cited by 142
Benito, S., & Lemaire, F. (1990) · Journal of Critical Care · doi:10.1016/0883-9441(90)90006-u · Cited by 98
Cited by
Costa, E. L. V., Borges, J. B., Melo, A., Suarez-Sipmann, F., Toufen, C., Bohm, S. H., & Amato, M. B. P. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1447-y · Cited by 506
Perspective on Lung Injury and Recruitment: A Skeptical Look at the Opening and Collapse Story
Hubmayr, R. D. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2001080-01cp · Cited by 312
Stahl, C. A., Möller, K., Schumann, S., Kuhlen, R., Sydow, M., Putensen, C., & Guttmann, J. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000227220.67613.0d · Cited by 289
Suarez-Sipmann, F., Böhm, S. H., Tusman, G., Pesch, T., Thamm, O., Reissmann, H., Reske, A., Magnusson, A., & Hedenstierna, G. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000251131.40301.e2 · Cited by 281
Pressure-Volume Curves of the Respiratory System
Harris, R. S. (2005) · Respiratory Care · doi:10.4187/respcare.05500078 · Cited by 200
Metadata
- Authors
- HICKLING, K. G.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-01-01
- Volume
- 163
- Issue
- 1
- Pages
- 69-78
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2115370751
- Cited by
- 312
- References
- 19
- FWCI
- 16.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.