Snoring and Sleep Architecture
The DOI matches its Crossref record.
Abstract
The purpose of this study was to examine whether snoring adversely affects sleep architecture and sleep efficiency, and thus may account for the frequent complaints of daytime tiredness and fatigue expressed by heavy snorers. We recruited eight self-confessed heavy snorers and six self-confessed nonsnorers. All subjects had full nocturnal polysomnography, including continuous monitoring of snoring, which was quantified by counting the number of snores per hour of sleep (snoring index), the number of snores per minute of snoring time (snoring frequency), maximal and mean nocturnal sound intensity (dBmax and dBmean, respectively). We found that even the self-confessed nonsnorers snored lightly, with significantly smaller frequency and index than the heavy snorers. Sleep architecture was similar in both groups. Distribution of snoring among the sleep stages differed for light and heavy snorers: light snorers snored uniformly throughout all sleep stages, whereas heavy snorers tended to snore more during slow-wave and REM sleep. Snoring frequency and snoring index were similar during all sleep stages in light snorers, but they were higher during slow-wave sleep in heavy snorers. Wakefulness time after sleep onset and sleep efficiency correlated significantly with the snoring index. We conclude that although snoring does not affect sleep architecture in general, it influences sleep efficiency and wakefulness time after sleep onset; this may have an adverse effect on daytime function of heavy snorers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Cause of Excessive Daytime Sleepiness
Guilleminault, C., Stoohs, R., Clerk, A., Cetel, M., & Maistros, P. (1993) · Chest · doi:10.1378/chest.104.3.781 · Cited by 897
Davies, R. J., Ali, N. J., & Stradling, J. R. (1992) · Thorax · doi:10.1136/thx.47.2.101 · Cited by 479
Sleep Apnea and Sleep Disruption in Obese Patients
Vgontzas, A. N. (1994) · Archives of Internal Medicine · doi:10.1001/archinte.154.15.1705 · Cited by 471
Radiofrequency Volumetric Tissue Reduction of the Palate in Subjects With Sleep-Disordered Breathing
Powell, N. B., Riley, R. W., Troell, R. J., Li, K., Blumen, M. B., & Guilleminault, C. (1998) · Chest · doi:10.1378/chest.113.5.1163 · Cited by 330
Cigarette Smoking and Sleep Disturbance
Phillips, B. A. (1995) · Archives of Internal Medicine · doi:10.1001/archinte.1995.00430070088011 · Cited by 304
Metadata
- Authors
- Hoffstein, V., Mateika, J. H., & Mateika, S.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1991-01
- Volume
- 143
- Issue
- 1
- Pages
- 92-96
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W2092264024
- Cited by
- 98
- References
- 0
- FWCI
- 2.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Snoring and Sleep Architecture. https://app.cochat.ai/papers/10.1164/ajrccm/143.1.92
- The paper
- Hoffstein, V., Mateika, J. H., & Mateika, S. (1991). Snoring and Sleep Architecture. American Review of Respiratory Disease. https://doi.org/10.1164/ajrccm/143.1.92
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.