Prospective Study of Nosocomial Pneumonia and of Patient and Circuit Colonization During Mechanical Ventilation with Circuit Changes Every 48 Hours Versus No Change
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Abstract Circuits on mechanical ventilators with cascade humidifiers are routinely changed every day or every other day, although humidifying cascades have been considered unlikely to increase the risk of respiratory infection because they do not generate aerosols. Moreover, changing ventilator tubings every 24 rather than every 48 h increases the risk of ventilator-associated pneumonia. To study the effects of ventilator circuit changes on the rate of nosocomial pneumonia and on patient and circuit colonization, 73 consecutive patients requiring continuous mechanical ventilation for more than 48 h were randomly assigned to either ventilator circuit changes every 48 h (Group 1, n = 38) or no change (Group 2, n = 35). Patients dying or being weaned before 96 h were not analyzed (Group 1 n = 3; Group 2 n = 7; leaving Group 1 n = 35 and Group 2 n = 28; p = 0.13). Ventilator-associated pneumonia was defined as the occurrence during mechanical ventilation or within 48 h after weaning of a new and persistent infiltrate on chest X-ray, purulent tracheal secretions, and a positive culture of a protected brush specimen (⩾ 103 cfu/ml). Bacterial colonization was assessed every 48 h by quantitative cultures of pharyngeal swab, tracheal aspirate, humidifying cascade, and expiratory tubing trap. The two groups were similar in terms of age, indication for and duration of ventilation, and severity of illness. The incidence of pneumonia was similar in both groups (11 of 35 and 8 of 28 in Groups 1 and 2, respectively; p = 0.8), as was the duration of ventilation before pneumonia (10.1 ± 5.8 versus 9.1 ± 2.9 days; p = 0.7). The level of colonization by both gram-positive and gram-negative bacteria was the same in both groups. We conclude that not changing ventilator circuits during mechanical ventilation has no adverse effect on the rate of nosocomial pneumonia or on patient and circuit colonization. Substantial savings in expenses of tubing and personnel time could be obtained without apparent adverse effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A simplified acute physiology score for ICU patients
GALL, J.-R. L., LOIRAT, P., ALPEROVITCH, A., GLASER, P., GRANTHIL, C., MATHIEU, D., MERCIER, P., THOMAS, R., & VILLERS, D. (1984) · Critical Care Medicine · doi:10.1097/00003246-198411000-00012 · Cited by 1,251
JOHANSON, W. G., PIERCE, A. K., SANFORD, J. P., & THOMAS, G. D. (1972) · Annals of Internal Medicine · doi:10.7326/0003-4819-77-5-701 · Cited by 1,087
Changing Pharyngeal Bacterial Flora of Hospitalized Patients: Emergence of Gram-Negative Bacilli
Johanson, W. G., Pierce, A. K., & Sanford, J. P. (1969) · New England Journal of Medicine · doi:10.1056/nejm196911202812101 · Cited by 910
Fagon, J.-Y., Chastre, J., Domart, Y., Trouillet, J.-L., Pierre, J., Darne, C., & Gibert, C. (1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/139.4.877 · Cited by 823
Driks, M. R., Craven, D. E., Celli, B. R., Manning, M., Burke, R. A., Garvin, G. M., Kunches, L. M., Farber, H. W., Wedel, S. A., & McCabe, W. R. (1987) · New England Journal of Medicine · doi:10.1056/nejm198711263172204 · Cited by 757
Risk factors for pneumonia and fatality in patients receiving continuous mechanical ventilation.
Craven, D. E., Kunches, L. M., Kilinsky, V., Lichtenberg, D. A., Make, B. J., & McCabe, W. R. (1986) · PubMed · Cited by 676
Diagnosis of Nosocomial Bacterial Pneumonia in Acute, Diffuse Lung Injury
Andrews, C. P., Coalson, J. J., Smith, J. D., & Johanson, W. G. (1981) · Chest · doi:10.1378/chest.80.3.254 · Cited by 482
Fagon, J.-Y., Chastre, J., Hance, A. J., Guiguet, M., Trouillet, J.-L., Domart, Y., Pierre, J., & Gibert, C. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/138.1.110 · Cited by 426
Wimberley, N., Faling, L. J., & Bartlett, J. G. (1979) · PubMed · doi:10.1164/arrd.1979.119.3.337 · Cited by 407
Chastre, J. E., Viau, F., Brun, P., Pierre, J., Dauge, M., Bouchama, A., Akesbi, A., & Gibert, C. (1984) · PubMed · doi:10.1164/arrd.1984.130.5.924 · Cited by 355
Self-citationComplications of assisted ventilation
Zwillich, C. W., Pierson, D. J., Creagh, C. E., Sutton, F. D., Schatz, E., & Petty, T. L. (1974) · The American Journal of Medicine · doi:10.1016/0002-9343(74)90440-9 · Cited by 349
Role of respiratory assistance devices in endemic nosocomial pneumonia
Cross, A. S., & Roup, B. (1981) · The American Journal of Medicine · doi:10.1016/0002-9343(81)90596-9 · Cited by 294
COMPLICATIONS OF ASSISTED VENTILATION: A PROSPECTIVE STUDY OF 354 CONSECUTIVE EPISODES
ZWILLICH, C. W., PIERSON, D. J., CREAGH, C. E., SUTTON, F. D., SCHATZ, E., & PETTY, T. L. (1975) · Survey of Anesthesiology · doi:10.1097/00132586-197510000-00022 · Cited by 289
The Potential Role of Inhalation Therapy Equipment in Nosocomial Pulmonary Infection*
Reinarz, J. A., Pierce, A. K., Mays, B. B., & Sanford, J. P. (1965) · Journal of Clinical Investigation · doi:10.1172/jci105195 · Cited by 289
Bacteriology of Hospital-Acquired Pneumonia
Bartlett, J. G. (1986) · Archives of Internal Medicine · doi:10.1001/archinte.146.5.868 · Cited by 268
Contaminated condensate in mechanical ventilator circuits. A risk factor for nosocomial pneumonia?
Craven, D. E., Goularte, T. A., & Make, B. J. (1984) · PubMed · Cited by 232
Long-term Respiratory Support and Risk of Pneumonia in Critically III Patients
Langer, M., Mosconi, P., Cigada, M., Mandelli, M., & The Intensive Care Unit Group of Infection Control (1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/140.2.302 · Cited by 217
Contamination of Mechanical Ventilators with Tubing Changes Every 24 or 48 Hours
Craven, D. E., Connolly, M. G., Lichtenberg, D. A., Primeau, P. J., & McCabe, W. R. (1982) · New England Journal of Medicine · doi:10.1056/nejm198206243062501 · Cited by 212
Serratia marcescens Infections from Inhalation Therapy Medications: Nosocomial Outbreak
SANDERS, C. V., LUBY, J. P., JOHANSON, W. G., BARNETT, J. A., & SANFORD, J. P. (1970) · Annals of Internal Medicine · doi:10.7326/0003-4819-73-1-15 · Cited by 170
Use of the Protected Specimen Brush in Patients with Endotracheal or Tracheostomy Tubes
Baughman, R. P., Thorpe, J. E., Staneck, J., Rashkin, M., & Frame, P. T. (1987) · Chest · doi:10.1378/chest.91.2.233 · Cited by 169
Torres, A., de la Bellacasa, J. P., Rodriguez‐Roisin, R., de Anta, M. T. J., & Agustí-Vidal, A. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/138.1.117 · Cited by 151
Nosocomial infections and hospital deaths
Gross, P. A., & Antwerpen, C. V. (1983) · The American Journal of Medicine · doi:10.1016/0002-9343(83)90453-9 · Cited by 127
Pneumonia in the Critically III Hospitalized Patient
Niederman, M. S., Craven, D. E., Fein, A. M., & Schultz, D. E. (1990) · CHEST Journal · doi:10.1378/chest.97.1.170 · Cited by 89
Bacterial Contamination of Aerosols
Pierce, A. K., & SANFORD, J. P. (1973) · Archives of Internal Medicine · doi:10.1001/archinte.1973.00320070152017 · Cited by 72
Cited by
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200405-644st · Cited by 5,877
Ventilator-associated Pneumonia
Chastre, J., & Fagon, J.-Y. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.7.2105078 · Cited by 2,812
Clinical and economic consequences of ventilator-associated pneumonia: A systematic review
Safdar, N., Dezfulian, C., Collard, H. R., & Saint, S. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000181731.53912.d9 · Cited by 1,086
Evidence-Based Clinical Practice Guideline for the Prevention of Ventilator-Associated Pneumonia
Dodek, P., Keenan, S., Cook, D., Heyland, D., Jacka, M., Hand, L., Muscedere, J., Foster, D., Mehta, N., Hall, R., et al. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-141-4-200408170-00011 · Cited by 546
Metadata
- Authors
- Dreyfuss, D., Djedaini, K., Weber, P., Brun, P., Lanore, J.-J., Rahmani, J., Boussougant, Y., & Coste, F.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1991-04
- Volume
- 143
- Issue
- 4_pt_1
- Pages
- 738-743
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W2038114251
- Cited by
- 237
- References
- 24
- FWCI
- 8.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.