The DOI matches its Crossref record.
Normal Standards for Ventilatory Function Using an Automated Wedge Spirometer 1
Abstract
Abstract A computer attachment was developed for a wedge spirometer that provided an immediate printout of a forced expiratory vital capacity, maximal mid-expiratory flow, forced expiratory volume in one second, the indirect maximal breathing capacity, peak or maximal expiratory flow, and maximal flow at 75 per cent, 50 per cent, and 25 per cent of the forced vital capacity. The maximal breathing capacity was measured in a separate maneuver. The circuitry was straightforward and relatively simple. The special purpose spirometer was in operation for more than 4 years without major problems and was especially useful in surveys as well as routine assessment of ventilatory function in a pulmonary function laboratory. Prediction standards of measurements of ventilatory function were derived from 879 male and 452 female, healthy nonsmokers, ranging in age from 15 to 79 years, who resided in Manitoba, Canada, which is essentially pollution-free. Negative correlations were obtained for each lung function with age; the largest negative correlations were obtained with maximal expiratory flow at 25 per cent of vital capacity and the forced expiratory volume in one second. All parameters correlated positively with height; the largest positive correlation was with the forced vital capacity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Asthma and irreversible airflow obstruction.
Brown, P. J., Greville, H. W., & Finucane, K. E. (1984) · Thorax · doi:10.1136/thx.39.2.131 · Cited by 320
Reference Values for Lung Function Tests in Men: Regression Equations with Smoking Variables
Hedenström, H., Malmberg, P., & Fridriksson, H. V. (1986) · Upsala Journal of Medical Sciences · doi:10.3109/03009738609178670 · Cited by 288
O'donnell, D. E., Sanii, R., & Younes, M. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/138.6.1510 · Cited by 131
Skeletal Muscle Inflammation and Nitric Oxide in Patients with COPD
Montes de Oca, M., Torres, S. H., De Sanctis, J., Mata, A., Hernández, N., & Tálamo, C. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00107404 · Cited by 123
Metadata
- Authors
- Cherniack, R. M., & Raber, M. B.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1972-07
- Volume
- 106
- Issue
- 1
- Pages
- 38-46
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W2212853496
- Cited by
- 326
- References
- 0
- FWCI
- 9.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Normal Standards for Ventilatory Function Using an Automated Wedge Spirometer 1. https://app.cochat.ai/papers/10.1164/arrd.1972.106.1.38
- The paper
- Cherniack, R. M., & Raber, M. B. (1972). Normal Standards for Ventilatory Function Using an Automated Wedge Spirometer 1. American Review of Respiratory Disease. https://doi.org/10.1164/arrd.1972.106.1.38
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.