The DOI matches its Crossref record.
Nosocomial Tuberculosis 1, 2
Abstract
Hospital employees are at risk of contracting tuberculosis from patients. The undiagnosed case with sputum-smear positive for acid-fast bacilli is the usual source case. However, even the smear-negative patient may pose a risk. This was documented by a high rate of skin test conversion in hospital staff exposed to a smear-negative, culture-positive patient in a respiratory intensive care unit. The patient required bronchoscopy, intubation, and assisted ventilation. Of susceptible hospital staff members who were exposed to the index case, 14 of 45 (31%) converted their PPD skin test. Ten of 13 (77%) susceptible hospital staff members present at the time of bronchoscopy converted, compared with 4 of 32 (12.5%) who were not present at bronchoscopy (Fischer's exact test p = 0.0006). Rough calculations suggest that during the bronchoscopy and intubation the index case generated at least 249 infectious units per hour. At the ventilation levels in this area, this resulted in 1 infectious unit of tuberculosis in each 68.9 cubic feet of air. Improved ventilation, high efficiency filters, and ultraviolet irradiation are effective recommended ways to clean the air of infectious particles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Siegel, J. D., Rhinehart, E., Jackson, M., & Chiarello, L. (2007) · American Journal of Infection Control · doi:10.1016/j.ajic.2007.10.007 · Cited by 3,456
Lewinsohn, D. M., Leonard, M. K., LoBue, P. A., Cohn, D. L., Daley, C. L., Desmond, E., Keane, J., Lewinsohn, D. A., Loeffler, A. M., Mazurek, G. H., et al. (2017) · Clinical Infectious Diseases · doi:10.1093/cid/ciw694 · Cited by 992
Transmission of Mycobacterium tuberculosis from patients smear-negative for acid-fast bacilli
Behr, M., Warren, S., Salamon, H., Hopewell, P., de Leon, A. P., Daley, C., & Small, P. (1999) · The Lancet · doi:10.1016/s0140-6736(98)03406-0 · Cited by 754
Rudnick, S. N., & Milton, D. K. (2003) · Indoor Air · doi:10.1034/j.1600-0668.2003.00189.x · Cited by 624
Natural Ventilation for the Prevention of Airborne Contagion
Escombe, A. R., Oeser, C. C., Gilman, R. H., Navincopa, M., Ticona, E., Pan, W., Martínez, C., Chacaltana, J., Rodríguez, R., Moore, D. A. J., et al. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040068 · Cited by 420
Tuberculosis among Health Care Workers
Menzies, D., Fanning, A., Yuan, L., & Fitzgerald, M. (1995) · New England Journal of Medicine · doi:10.1056/nejm199501123320206 · Cited by 378
Cole, E. C., & Cook, C. E. (1998) · American Journal of Infection Control · doi:10.1016/s0196-6553(98)70046-x · Cited by 317
Updates on the risk factors for latent tuberculosis reactivation and their managements
Ai, J.-W., Ruan, Q.-L., Liu, Q.-H., & Zhang, W.-H. (2016) · Emerging Microbes & Infections · doi:10.1038/emi.2016.10 · Cited by 298
Airborne Infection: Theoretical Limits of Protection Achievable by Building Ventilation
Nardell, E. A., Keegan, J., Cheney, S. A., & Etkind, S. C. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.2.302 · Cited by 261
Infectious respiratory illnesses and their impact on healthcare workers: a review
Low, J., & Wilder-Smith, A. (2005) · Annals of the Academy of Medicine, Singapore · doi:10.47102/annals-acadmedsg.v34n1p105 · Cited by 46
Metadata
- Authors
- Catanzaro, A.
- Venue
- American Review of Respiratory Disease
- Publisher
- Oxford University Press (OUP)
- Published
- 1982-05
- Volume
- 125
- Issue
- 5
- Pages
- 559-562
- ISSN
- 0003-0805 (ISSN-L)
- OpenAlex
- W1846497036
- Cited by
- 177
- References
- 0
- FWCI
- 2.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.