Meta-analysis of acute lung injury and acute respiratory distress syndrome trials testing low tidal volumes.
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
The use of low tidal volumes (5-7 ml/kg measured body weight) as a protective lung strategy is becoming widely recommended for patients with acute lung injury (ALI) and acute respiratory distress syndrome (ARDS) requiring mechanical ventilation (1-4). However, clinical trials testing low tidal volumes in ALI and ARDS have not shown uniform results (5-7). This has led some experts to recommend avoiding high tidal volumes during mechanical ventilation in these patients (6, 8), whereas other experts advocate using very low tidal volumes (1-4). Our concern, shared by others (9), was that trials showing low tidal volumes to be beneficial did not use control arms that reflected the current best practice standards at the time. Instead, the trials compared very low tidal volumes (5-7 ml/kg measured body weight) with traditional tidal volumes (10 ml/kg or more), which were higher than those routinely used (8-9 ml/kg) (10-13). As a result, those studies were inconclusive. We performed a meta-analysis to investigate why five randomized, prospective clinical trials produced disparate results and to critically evaluate the basis for recommending low tidal volume ventilation in ALI and ARDS (3-7). In this analysis, we demonstrate that there is a significant difference in the effects of low tidal volume on survival among the five trials. We then compare the tidal volumes and plateau airway pressures from the five trials to determine whether these account for differences in survival. In contrast to previous explanations based on the low tidal volumes tested (4), this meta-analysis demonstrates that significant differences in the control arms can account for the discrepant results among these five trials.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These studies showed differing results, which may have been caused by differences in airway pressures in the treatment and control groups [423, 424, 428].”
From Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021 (2021) · cites this paper as [428]
Citations
Cites
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome.
Amato, M. B. P., Barbas, C. S. V., Medeiros, D. M., Magaldi, R. B., Schettino, G. P., Lorenzi-Filho, G., Kairalla, R. A., Deheinzelin, D., Munoz, C., Oliveira, R., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802053380602 · Cited by 3,654
Kress, J. P., Pohlman, A. S., O'Connor, M. F., & Hall, J. B. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005183422002 · Cited by 2,981
Esteban, A. (2002) · JAMA · doi:10.1001/jama.287.3.345 · Cited by 1,779
Tidal ventilation at low airway pressures can augment lung injury.
Muscedere, J. G., Mullen, J. B., Gan, K., & Slutsky, A. S. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.5.8173774 · Cited by 1,244
The Use of Continuous IV Sedation Is Associated With Prolongation of Mechanical Ventilation
Kollef, M. H., Levy, N. T., Ahrens, T. S., Schaiff, R., Prentice, D., & Sherman, G. (1998) · Chest · doi:10.1378/chest.114.2.541 · Cited by 916
Stewart, T. E., Meade, M. O., Cook, D. J., Granton, J. T., Hodder, R. V., Lapinsky, S. E., Mazer, C. D., McLean, R. F., Rogovein, T. S., Schouten, B. D., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802053380603 · Cited by 888
BROCHARD, L., ROUDOT-THORAVAL, F., ROUPIE, E., DELCLAUX, C., CHASTRE, J., FERNANDEZ-MONDÉJAR, E., CLÉMENTI, E., MANCEBO, J., FACTOR, P., MATAMIS, D., et al. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.6.9801044 · Cited by 800
ESTEBAN, A., ANZUETO, A., ALÍA, I., GORDO, F., APEZTEGUÍA, C., PÁLIZAS, F., CIDE, D., GOLDWASER, R., SOTO, L., BUGEDO, G., et al. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.5.9902018 · Cited by 780
Brower, R. G., Shanholtz, C. B., Fessler, H. E., Shade, D. M., White, P., Wiener, C. M., Teeter, J. G., Dodd-o, J. M., Almog, Y., & Piantadosi, S. (1999) · Critical Care Medicine · doi:10.1097/00003246-199908000-00015 · Cited by 575
Research works printed but not linked: 1
- 2000, N Engl J Med, 343, 813
Cited by
Items 101–200 of 415
Maslow, A. D., Stafford, T. S., Davignon, K. R., & Ng, T. (2013) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2013.01.021 · Cited by 54
Mechanical ventilation of acute respiratory distress syndrome
Ochiai, R. (2015) · Journal of Intensive Care · doi:10.1186/s40560-015-0091-6 · Cited by 62
“to the extremely higher plateau pressure in the control group of two beneficial groups [18].”
Backgroundde Prost, N., Costa, E. L. V., Wellman, T. J., Musch, G., Winkler, T., Tucci, M. R., Harris, R. S., Venegas, J. G., & Melo, M. F. V. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00311.2011 · Cited by 50
Yalcin, H. C., Hallow, K. M., Wang, J., Wei, M., Ou‐Yang, H. D., & Ghadiali, S. N. (2009) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.90562.2008 · Cited by 55
“Although these low volume ventilation strategies minimize the amount of stretching deformations experienced by EpC, several studies (8, 12, 26) have demonstrated that even these low volume strategies result in significant lung damage.”
BackgroundOf Principles and Protocols and Weaning
Tobin, M. J. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2401006 · Cited by 49
Moran, J. L., Bersten, A. D., & Solomon, P. J. (2005) · Intensive Care Medicine · doi:10.1007/s00134-004-2506-z · Cited by 53
“and it may be harmful” [8] and support the conclusions (based upon an individual patient analysis) of Amato et al.”
BackgroundMethodResultInfluentialAre We Really Reducing Tidal Volume—And Should We?
Ricard, J.-D. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2303003 · Cited by 48
Fernández, A., Modesto, V., Rimensberger, P. C., Korang, S. K., Iyer, N. P., Cheifetz, I. M., & on behalf of the Second Pediatric Acute Lung Injury Consensus Conference (PALICC-2) of the Pediatric Acute Lung Injury and Sepsis Investigators (PALISI) Network (2023) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000003159 · Cited by 55
Regli, A., Mahendran, R., Fysh, E. T. H., Roberts, B., Noffsinger, B., Keulenaer, B. L. D., Singh, B., & van Heerden, P. V. (2012) · Critical Care · doi:10.1186/cc11840 · Cited by 44
“2) We applied tidal volumes of 8 ml/ kg, which are higher than currently recommended for mechanical ventilation of patients with ALI/ARDS and have the potential to cause or further exacerbate ventilator induced lung injury (VILI) [25,30].”
MethodAdlakha, A., Pavlou, M., Walker, D. A., Copas, A. J., Dufty, N. E., Batson, S. D., Edwards, S., Singer, M., & Miller, R. F. (2011) · International Journal of STD & AIDS · doi:10.1258/ijsa.2011.010496 · Cited by 45
Closed-Loop Ventilation: An Emerging Standard of Care?
Wysocki, M., & Brunner, J. X. (2007) · Critical Care Clinics · doi:10.1016/j.ccc.2006.12.011 · Cited by 45
Severe novel influenza A (H1N1) infection in cancer patients
Hajjar, L. A., Mauad, T., Galas, F. R. B. G., Kumar, A., da Silva, L. F. F., Dolhnikoff, M., Trielli, T. R., de Almeida, J. P., Borsato, M. R. L., Abdalla, E., et al. (2010) · Annals of Oncology · doi:10.1093/annonc/mdq254 · Cited by 42
“Most patients needed mechanical ventilation (five of eight), and they were all treated with protective strategies according to the ARDS Network protocol [19].”
Method“Lies, Damned Lies …” and Observational Studies in Comparative Effectiveness Research
Albert, R. K. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201212-2187oe · Cited by 42
“RCTs comparing one treatment with another can similarly be criticized when neither intervention represents usual care, as was thought to be the case with the study of low tidal volumes in patients with acute respiratory distress syndrome (8).”
ResultHough, C. L., Kallet, R. H., Ranieri, V. M., Rubenfeld, G. D., Luce, J. M., & Hudson, L. D. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000155782.86244.42 · Cited by 41
Evidence-Based Management of Acute Lung Injury and Acute Respiratory Distress Syndrome
Kallet, R. H. (2004) · Respiratory Care · doi:10.4187/respcare.04490793 · Cited by 48
Acute Lung Injury After Thoracic Surgery
Eichenbaum, K. D., & Neustein, S. M. (2010) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2009.10.032 · Cited by 48
Kalil, A. C., & Sun, J. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002291 · Cited by 40
“Our results unambiguously demonstrate that it is important to replicate the results of each of these trials in well designed confirmatory studies if we want to provide patient care based on scientifically sound evidence. Further, the many study design issues raised, e.g. standard of care of control groups (EGDT and Lo…”
ResultNormalizing physiological variables in acute illness: five reasons for caution
Kavanagh, B. P., & Meyer, L. J. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2729-7 · Cited by 39
“Indeed it is important to note that several detailed critiques have generated significant debate about the interpretation and incorporation of clinical studies into practice [2, 30, 58, 59, 60 ].”
BackgroundWhat Is Evidence-Based Medicine and Why Should I Care?
HESS, D. R. (2004) · Respiratory Care · doi:10.4187/respcare.04490730 · Cited by 50
New treatment strategies for severe sepsis and septic shock
Patel, G. P., Gurka, D. P., & BALK, R. A. (2003) · Current Opinion in Critical Care · doi:10.1097/00075198-200310000-00009 · Cited by 53
Should A Tidal Volume of 6 mL/kg Be Used in All Patients?
Davies, J. D., Senussi, M. H., & Mireles‐Cabodevila, E. (2016) · Respiratory Care · doi:10.4187/respcare.04651 · Cited by 40
Mechanical Ventilation: What Have We Learned?
Fenstermacher, D., & Hong, D. (2004) · Critical Care Nursing Quarterly · doi:10.1097/00002727-200407000-00006 · Cited by 50
Petrucci, N., & Iacovelli, W. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000118102.93688.97 · Cited by 43
“landmark clinical trials of patients with ARDS (12).”
BackgroundResultInfluentialAlbaiceta, G. M., Piacentini, E. A., Villagra, A. L. R., López‐Aguilar, J., Taboada, F., & Blanch, L. L. (2003) · Critical Care Medicine · doi:10.1097/01.ccm.0000090003.87219.aa · Cited by 37
Mechanical Ventilation and Air Leaks After Lung Biopsy for Acute Respiratory Distress Syndrome
Cho, M. H., Malhotra, A., Donahue, D. M., Wain, J. C., Harris, R. S., Karmpaliotis, D., & Patel, S. R. (2006) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2006.02.022 · Cited by 37
“While the results of the ARDSNet study advocating lower tidal volumes and ventilatory pressures have generally been accepted, aspects of the study have been questioned [27] and ventilation with low tidal volumes is still not routinely applied [28].”
ResultAcute respiratory distress syndrome: evaluation and management.
Cortés, I., Peñuelas, Ó., & Esteban, A. (2012) · PubMed · Cited by 48
Research ethics and consent in the intensive care unit
Luce, J. M. (2003) · Current Opinion in Critical Care · doi:10.1097/00075198-200312000-00013 · Cited by 36
Role of Airway Recruitment and Derecruitment in Lung Injury
Ghadiali, S. N., & Huang, Y. (2011) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v39.i4.40 · Cited by 42
Drazen, J. M. (2003) · New England Journal of Medicine · doi:10.1056/nejme030031 · Cited by 36
Intraoperative mechanical ventilation for the pediatric patient
Kneyber, M. C. J. (2015) · Best practice & research. Clinical anaesthesiology · doi:10.1016/j.bpa.2015.10.001 · Cited by 41
Vinko Tomicic, F., Espinoza, M., Andresen, M., Molina, J., Calvo, M. A., Héctor Ugarte, E., de Godoy, J. A. P., Gálvez, S. C., Maurelia, J. C., Delgado, I., et al. (2008) · Revista médica de Chile · doi:10.4067/s0034-98872008000800001 · Cited by 54
Ahn, H. J., Kim, J. A., Yang, M., Shim, W. S., Park, K., & Lee, J. J. (2012) · Anaesthesia and Intensive Care · doi:10.1177/0310057x1204000505 · Cited by 34
Ethics and research in critical care
SILVERMAN, H. J., & Lemaire, F. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0305-4 · Cited by 39
“whereby an experimental therapy is compared against an alleged inferior control strategy, have been raised in several critical care trials [22, 23, 24, 25, 26, 27].”
ResultAdult respiratory distress syndrome
Cutts, S., Talboys, R., Paspula, C., Prempeh, E. M., Fanous, R., & Ail, D. (2016) · Annals of The Royal College of Surgeons of England · doi:10.1308/rcsann.2016.0238 · Cited by 34
Meta-analysis of tidal volumes in ards
Parshuram, C. S., & Kavanagh, B. P. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.5.950 · Cited by 33
Controversies around Lung Protective Mechanical Ventilation
Stewart, T. E. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2210002 · Cited by 35
Influence of tidal volume on stroke volume variation. Does it really matter?
Michard, F., Teboul, J., & Richard, C. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1886-9 · Cited by 33
Improving clinical trial design in acute lung injury
Wood, K. A., Huang, D. T., & Angus, D. C. (2003) · Critical Care Medicine · doi:10.1097/01.ccm.0000057908.11686.b3 · Cited by 33
Spece, L. J., Mitchell, K. H., Caldwell, E., Gundel, S. J., Jolley, S. E., & Hough, C. L. (2017) · Journal of Critical Care · doi:10.1016/j.jcrc.2017.10.021 · Cited by 32
“Previous literature has suggested that physicians may not pursue low tidal volumes in patients with ARDSwhen plateau pressures are not high [34], and some argue that a Pplat b30 cm H2O is safe [35,36].”
BackgroundVistisen, S. T., Struijk, J. J., & LARSSON, A. (2009) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2008.01893.x · Cited by 32
What Is the Legacy of the National Institutes of Health Acute Respiratory Distress Syndrome Network?
Kallet, R. H. (2009) · Respiratory Care · doi:10.4187/002013209793800330 · Cited by 31
Is it better to consent to an RCT or to care? Μηδεν αγαν (“nothing in excess”)
Dreyfuss, D. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2493-0 · Cited by 34
The Role of a Journal in a Scientific Controversy
Tobin, M. J. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2307001 · Cited by 35
“In December 2002, the Journal published a Critical Care Perspective by Eichacker and colleagues ( 6 ) focusing on these five trials.”
BackgroundInfluentialDreyfuss, D., Ricard, J.-D., & Gaudry, S. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-4062-0 · Cited by 34
Jaswal, D. S., Leung, J. M., Sun, J., Cui, X., Li, Y., Kern, S. J., Welsh, J. A., Natanson, C., & Eichacker, P. Q. (2014) · Critical Care Medicine · doi:10.1097/ccm.0000000000000504 · Cited by 34
“At the trial’s publication, questions were raised as to whether it had demonstrated benefit with low V T as opposed to introducing harm with the high “traditional” control V T of 12 mL/ kg PBW (124).”
BackgroundSelf-citationBelda, T. E., Gajic, O., Rabatin, J. T., & Harrison, B. A. (2004) · Respiratory Care · doi:10.4187/respcare.04491015 · Cited by 29
“17 Following the clinician-education intervention, the use of potentially injurious high-V T ventilation became less common at our institution.”
Aguirre-Bermeo, H., Morán, I., Bottiroli, M., Italiano, S., Parrilla, F. J., Plazolles, E., Roche‐Campo, F., & Mancebo, J. (2016) · Annals of Intensive Care · doi:10.1186/s13613-016-0183-z · Cited by 31
“Background Mechanical ventilation in patients with acute respiratory distress syndrome (ARDS) must combine both low tidal volumes (Vt) and adequate positive end-expiratory pressure (PEEP) [1, 2].”
BackgroundSchultz, M. J., Wolthuis, E. K., Moeniralam, H. S., & Levi, M. M. (2005) · Journal of Critical Care · doi:10.1016/j.jcrc.2005.05.007 · Cited by 29
“Patients in the control arm were not mechanically ventilated in a standard manner; on the contrary, these patients were ventilated with significantly larger tidal volumes than before randomization [18].”
MethodShould dynamic parameters for prediction of fluid responsiveness be indexed to the tidal volume?
Vistisen, S. T., Koefoed-Nielsen, J., & LARSSON, A. (2009) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2009.02114.x · Cited by 29
“5)* PEP (ms) 63 (17) 53 (25) 49 (14)* 39 (9)* 36 (7)* Hemoglobin (mmol/l) 5.”
Misrepresenting “Usual Care” in Research: An Ethical and Scientific Error
Macklin, R., & Natanson, C. (2020) · The American Journal of Bioethics · doi:10.1080/15265161.2019.1687777 · Cited by 28
“…a clinician during routine management of a mechanically ventilated patient to raise breath size and permit airway pressures to go to the abnormally high levels as allowed in this trial without a compelling reason (Deans et al. 2006, 2007; Eichacker et al. 2002; Esteban et al. 2000; Slutsky 1993).”
BackgroundSelf-citationCon: Low Tidal Volumes Are Indicated During One-Lung Ventilation
Gal, T. J. (2006) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000223678.64129.7c · Cited by 28
“Here one should use either ideal or predicted BW (4).”
BackgroundDembinski, R., Henzler, D., Bensberg, R., sse, B. P., Rossaint, R., & Kuhlen, R. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000090319.21491.91 · Cited by 28
“In a recently published metaanalysis of trials testing low Vt ventilation in ALI, it has been pointed out that high levels of Pmean are associated with an increasing mortality rate (26).”
BackgroundFuchs, H. W., Mendler, M. R., Scharnbeck, D., Ebsen, M., & Hummler, H. (2011) · PLoS ONE · doi:10.1371/journal.pone.0023816 · Cited by 27
“In our surfactant depletion model the use of tidal volumes in the range of 4–5 ml/kg associated with moderate hypercapnia protected from alveolar edema formation as compared to the accepted and commonly applied tidal volumes of 8– 10 ml/kg [11,19] with normocapnia.”
MethodResultVillar, J., Pérez‐Méndez, L., Aguirre‐Jaime, A., & Kacmarek, R. M. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2519-7 · Cited by 27
“Changing medical practice is a very difficult task, but retrospective analysis and clinical studies suggest that clinical practice at the time that the ARDSnet trial was performed was already tending towards lower tidal volumes [14, 15, 16].”
Gordo-Vidal, F., Gómez-Tello, V., Palencia-Herrejón, E., Latour-Pérez, J., Sánchez, B., & Díaz-Alersi, R. (2007) · Medicina Intensiva · doi:10.1016/s0210-5691(07)74856-8 · Cited by 29
BALK, R. A. (2006) · Yearbook of Critical Care Medicine · doi:10.1016/s0734-3299(08)70016-9 · Cited by 26
Interventions to improve long-term outcomes after critical illness
Rubenfeld, G. D. (2007) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e3282efdea5 · Cited by 25
Eslami, S., Abu–Hanna, A., Schultz, M. J., de Jonge, E., & de Keizer, N. F. (2011) · Journal of Critical Care · doi:10.1016/j.jcrc.2011.07.082 · Cited by 25
Is the Current Management of Severe Sepsis and Septic Shock Really Evidence Based?
Vincent, J. (2006) · PLoS Medicine · doi:10.1371/journal.pmed.0030346 · Cited by 25
“However, only two tidal volumes were compared and the high tidal volume chosen for the study was somewhat higher than the values usually applied [19].”
ResultBasic Ventilator Management: Lung Protective Strategies
Donahoe, M. P. (2006) · Surgical Clinics of North America · doi:10.1016/j.suc.2006.08.005 · Cited by 25
Ventilator-induced Lung Injury
Bigatello, L. M., & Pesenti, A. M. (2009) · Anesthesiology · doi:10.1097/aln.0b013e3181b76545 · Cited by 24
Hypercapnic acidosis and compensated hypercapnia in control and pulmonary hypertensive piglets
Lee, K. J., Hernández, G., & Gordon, J. B. (2003) · Pediatric Pulmonology · doi:10.1002/ppul.10340 · Cited by 24
van Ruler, O., Schultz, M. J., Reitsma, J. B., Gouma, D. J., & Boermeester, M. A. (2009) · Surgical Infections · doi:10.1089/sur.2008.012 · Cited by 28
“…[70], control patients received higher tidal volumes (12 mL = kg of predicted body weight) than are common in standard care (i.e., 10 mL = kg) [71], leading to higher airway pressures around a threshold of 35cm H 2 O. Airway pressures above this threshold were considered by many to be harmful [69].”
Huang, Y., Yang, Y., Chen, Q., Liu, S., Liu, L., Pan, C. S., Yang, C., & Qiu, H. (2013) · Journal of Surgical Research · doi:10.1016/j.jss.2013.05.012 · Cited by 23
Ventilator-induced lung injury in children: a reality?
Koopman, A. A., de Jager, P., Blokpoel, R. G. T., & Kneyber, M. C. J. (2019) · Annals of Translational Medicine · doi:10.21037/atm.2019.09.13 · Cited by 29
“No single threshold for Vt to be associated with adverse outcome could be identified in this systematic review, mirroring the three negative adult randomized trials in which Vt ~7 mL/kg was compared with ~10 mL/kg (23).”
BackgroundBellomo, R., Cass, A., Cole, L., Finfer, S. R., Gallagher, M., Goldsmith, D., Myburgh, J., Norton, R., & Scheinkestel, C. D. (2008) · Blood Purification · doi:10.1159/000148400 · Cited by 24
Kneyber, M. C. J., & Rimensberger, P. C. (2012) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0b013e31824fbc37 · Cited by 23
“In these three studies, the Vt used in both study arms was around 7 mL/kg and 10 mL/kg respectively, but the observed plateau pressure was < 32 cm H2O in both arms, suggesting that pressure limitation might have its role in lung protection as well (8).”
BackgroundMethodShorofsky, M., Jayaraman, D., Lellouche, F., Husa, R., & Lipes, J. (2014) · Acute Cardiac Care · doi:10.3109/17482941.2013.869345 · Cited by 22
Pediatric Acute Respiratory Distress Syndrome
Cheifetz, I. M. (2011) · Respiratory Care · doi:10.4187/respcare.01515 · Cited by 26
Better conduct of clinical trials: The control group in critical care trials
Takala, J. A. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181922bf4 · Cited by 22
SARS in the intensive care unit
Joynt, G. M., & Yap, H. (2004) · Current Infectious Disease Reports · doi:10.1007/s11908-004-0013-6 · Cited by 24
Extracorporeal support for patients with acute respiratory distress syndrome
Finney, S. J. (2014) · European Respiratory Review · doi:10.1183/09059180.00005514 · Cited by 21
Ventrice, E., Martí‐Sistac, O., Gonzalvo, R., Villagra, A. L. R., López‐Aguilar, J., & Blanch, L. L. (2007) · Medicina Intensiva · doi:10.1016/s0210-5691(07)74779-4 · Cited by 21
Intraoperative protective ventilation strategies in lung transplantation
Verbeek, G. L., & Myles, P. S. (2013) · Transplantation Reviews · doi:10.1016/j.trre.2012.11.004 · Cited by 22
“Low tidal volume mechanical ventilation has been accepted as standard practice in patients with acute respiratory distress syndrome (ARDS) and has been demonstrated to minimise ventilator-associated lung injury in non-ARDS patients, thereby reducingmorbidity andmortality associated withmechanical ventilation [15,25].”
BackgroundBojmehrani, A., Bergeron-Duchesne, M., Bouchard, C., Simard, S., Bouchard, P.-A., Vanderschuren, A., L’Her, E., & Lellouche, F. (2013) · Respiratory Care · doi:10.4187/respcare.02732 · Cited by 22
“Postoperatively, heights were visually estimated (4) by one clinician, and (5) subjects (bedridden in a supine position) were subsequently measured with a tape measure.”
MethodAdoption of Lower Tidal Volume Ventilation Improves With Feedback and Education
Wolthuis, E. K., Kesecioğlu, J., Hassink, L. H., Determann, R. M., Korevaar, J. C., & Schultz, M. J. (2007) · Respiratory Care · doi:10.4187/respcare.07521761 · Cited by 25
“3–5 Poor recognition by physicians of ALI/ARDS,6 concerns over hypercapnia, acidosis, and hypoxemia,7 as well as fear of increased need for sedation to maintain ventilator synchrony and comfort are several of the barriers to the use of lower VT.(8,9) In addition, the importance of using PBW (ie, weight based on patien…”
Beyond randomized, controlled trials
Dreyfuss, D. (2004) · Current Opinion in Critical Care · doi:10.1097/01.ccx.0000144763.88787.e8 · Cited by 20
Fundamentos de la ventilación mecánica en el síndrome de distrés respiratorio agudo
Vinko Tomicic, F., Fuentealba, A., Martínez, E., Graf, J., & Borges, J. B. (2010) · Medicina Intensiva · doi:10.1016/j.medin.2009.10.005 · Cited by 25
CO2 elimination at varying inspiratory pause in acute lung injury
Aboab, J., Niklason, L., Uttman, L., Kouatchet, A., Brochard, L. J., & Jonson, B. (2006) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2007.00699.x · Cited by 19
“In acute lung injury and acute respiratory distress syndrome (ALI/ARDS) lung protective ventilation at low tidal volume, VT, may lead to hypoventilation and hypercarbia (Eichacker et al., 2002).”
BackgroundAdvances in ventilator-associated lung injury: prevention is the target
Sutherasan, Y., D’Antini, D., & Pelosi, P. P. (2014) · Expert Review of Respiratory Medicine · doi:10.1586/17476348.2014.890519 · Cited by 21
“On the other hand, an unnecessary reduction in VT may lead to atelectrauma, induced by repetitive opening and closing of alveolar units [100].”
BackgroundVentilation Strategies and Adjunctive Therapy in Severe Lung Disease
Kissoon, N. “., Rimensberger, P. C., & BOHN, D. J. (2008) · Pediatric Clinics of North America · doi:10.1016/j.pcl.2008.02.012 · Cited by 22
“In the first instance, a large number of subjects were screened for study entry but not included, and a significant number of subjects in the 12 mL/kg arm of the study actually had their tidal volumes increased following randomization, which begs the question as to whether at least part of the outcome difference was b…”
BackgroundNieman, G. F., Satalin, J. M., Andrews, P., Wilcox, K., Aiash, H., Baker, S., Kollisch-Singule, M. C., Madden, M., Gatto, L. A., & Habashi, N. M. (2018) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0000000000002050 · Cited by 19
Using computerized medical databases to measure and to improve the quality of intensive care
Rubenfeld, G. D. (2004) · Journal of Critical Care · doi:10.1016/j.jcrc.2004.08.004 · Cited by 18
Protecting Participants of Clinical Trials Conducted in the Intensive Care Unit
Flanagan, B. M., Philpott, S. M., & Strosberg, M. A. (2011) · Journal of Intensive Care Medicine · doi:10.1177/0885066610390867 · Cited by 23
Defining the standard of care in randomized controlled trials of titrated therapies
Deans, K. J., Minneci, P. C., Eichacker, P. Q., & Natanson, C. (2004) · Current Opinion in Critical Care · doi:10.1097/01.ccx.0000145097.36069.44 · Cited by 18
Self-citationParshuram, C. S., & Kavanagh, B. P. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200403-342cp · Cited by 18
Metaanalysis of Tidal Volume in ARDS
Amato, M. B. P., Brochard, L. J., Stewart, T. E., Brower, R. G., Eichacker, P. Q., Banks, S. M., & Natanson, C. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.168.5.950 · Cited by 19
Self-citationCutts, S., Talboys, R., Paspula, C., Prempeh, E. M., Fanous, R., & Ail, D. (2016) · Bulletin of The Royal College of Surgeons of England · doi:10.1308/rcsbull.2017.12 · Cited by 18
Airway pressure release ventilation and pediatrics: theory and practice
Frawley, P. M., & Habashi, N. M. (2004) · Critical Care Nursing Clinics of North America · doi:10.1016/j.ccell.2004.04.003 · Cited by 17
“Although the recent ARDSNet strategy of low tidal volume ventilation [47] attempts to standardize low tidal volume ventilation, the results of the trial remain controversial regarding ideal tidal volume [19,48–50].”
BackgroundTherapie des akuten Lungenversagens in einem Behandlungszentrum
Henzler, D., Dembinski, R., Kopp, R., Hawickhorst, R., Rossaint, R., & Kuhlen, R. (2004) · Der Anaesthesist · doi:10.1007/s00101-004-0653-9 · Cited by 20
Rezoagli, E., Laffey, J. G., Madotto, F., Protti, A., Pham, T. O., Pesenti, A., Bellani, G., & Brochard, L. J. (2025) · European Respiratory Journal · doi:10.1183/13993003.00742-2025 · Cited by 21
Oh, D. K., Lee, M. G., Choi, E. Y., Lim, J., Lee, H.-K., Kim, S. C., Lim, C., Koh, Y., & Hong, S. (2013) · Journal of Critical Care · doi:10.1016/j.jcrc.2013.03.001 · Cited by 16
“Although lowTV mechanical ventilation is a widely accepted crucial intervention, some authors insist intermediate-TV mechanical ventilation is also related to better clinical outcome than conventional mechanical ventilation [13,14].”
BackgroundResultPrinciples of artificial ventilation
Gould, T., & de Beer, J. M. A. (2007) · Anaesthesia & intensive care medicine · doi:10.1016/j.mpaic.2006.12.016 · Cited by 19
Therapie des akuten Lungenversagens: Umfrage an deutschen ARDS-Zentren und wissenschaftliche Evidenz
Kredel, M., Bierbaum, D., Lotz, C., Küstermann, J., Roewer, N., & Muellenbach, R. M. (2015) · Der Anaesthesist · doi:10.1007/s00101-015-0010-1 · Cited by 19
Ventilator-Associated Lung Injury
Jaecklin, T., Jarreau, P., & Kavanagh, B. P. (2014) · Springer eBooks · doi:10.1007/978-3-642-01219-8_33 · Cited by 16
Low tidal volume, high respiratory rate and auto-PEEP: the importance of the basics.
Patroniti, N. A., & Pesenti, A. M. (2003) · Critical Care · doi:10.1186/cc1883 · Cited by 16
“As always, and in spite of these important results, some aspects of the study design and speculation regarding the mechanisms involved generated some controversial interpretations [2–5].”
Cyclic deformation-induced injury and differentiation of rat alveolar epithelial type II cells
Ye, H., Zhan, Q., Ren, Y., Liu, X., Yang, C., & Wang, C. (2011) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2011.11.011 · Cited by 17
Predicted body weight during mechanical ventilation: using arm demispan to aid clinical assessment
Deane, A. M., Reid, D. A., & Tobin, A. E. (2008) · Critical Care and Resuscitation · doi:10.1016/s1441-2772(23)01084-0 · Cited by 16
Driving Pressure and Mechanical Power: The Return of Physiology in Pediatric Mechanical Ventilation*
Kneyber, M. C. J. (2021) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000002829 · Cited by 15
Wang, W., Scharfstein, D. O., Wang, C., Daniels, M. J., Needham, D. M., & Brower, R. G. (2011) · Journal of the Royal Statistical Society Series C (Applied Statistics) · doi:10.1111/j.1467-9876.2010.00757.x · Cited by 15
“The editorial argued that, in five randomized trials of ALI mechanical ventilation strategies (including the tidal volume trial), clinical outcomes were better in the study groups that received low tidal volumes only when the mean plateau pressures in the traditional study groups exceeded 32 cm H2O.”
Influential
Metadata
- Authors
- Eichacker, P. Q., Gerstenberger, E. P., Banks, S. M., Cui, X., & Natanson, C.
- Affiliations
- National Institutes of Health (US)
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-12-01
- Volume
- 166
- Issue
- 11
- Pages
- 1510-1514
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2153339769
- Cited by
- 423
- References
- 24
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 3 · 2023: 8 · 2022: 5 · 2021: 7 · 2020: 4 · 2019: 10 · 2018: 5 · 2017: 12 · 2016: 8 · 2015: 11 · 2014: 18 · 2013: 16 · 2012: 20
- FWCI
- 9.47
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Respiratory and Critical Care Medicine (publishedVersion)
- PubMed (publishedVersion)
- DigitalGeorgetown (Georgetown University Library) (submittedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Neonatal Respiratory Health Research
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Nosocomial Infections in ICU
- Keywords
- low tidal volume ventilation, acute lung injury, acute respiratory distress syndrome, mechanical ventilation, survival outcomes, trial heterogeneity
- MeSH terms
- Acute Disease, Humans, Lung Diseases, Respiratory Distress Syndrome, Tidal Volume, Randomized Controlled Trials as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.