Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 161

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Detection of Airborne Rhinovirus and Its Relation to Outdoor Air Supply in Office Environments

Myatt, Theodore A., Johnston, Sebastian L., Zuo, Zhengfa, Wand, Matthew, Kebadze, Tatiana, Rudnick, Stephen, Milton, Donald K.·2004·American Journal of Respiratory and Critical Care Medicine

Abstract

Rhinoviruses are major causes of morbidity in patients with respiratory diseases; however, their modes of transmission are controversial. We investigated detection of airborne rhinovirus in office environments by polymerase chain reaction technology and related detection to outdoor air supply rates. We sampled air from 9 A.M. to 5 P.M. each workday, with each sample run for 1 work week. We directly extracted RNA from the filters for nested reverse transcriptase-polymerase chain reaction analysis of rhinovirus. Nasal lavage samples from building occupants with upper respiratory infections were also collected. Indoor carbon dioxide (CO2 concentrations were recorded every 10 minutes as a surrogate for outdoor air supply. To increase the range of CO2 concentrations, we adjusted the outdoor air supply rates every 3 months. Generalized additive models demonstrated an association between the probability of detecting airborne rhinovirus and a weekly average CO2 concentration greater than approximately 100 ppm, after controlling for covariates. In addition, one rhinovirus from a nasal lavage contained an identical nucleic acid sequence similar to that in the building air collected during the same week. These results suggest that occupants in buildings with low outdoor air supply may have an increased risk of exposure to infectious droplet nuclei emanating from a fellow building occupant.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.200306-760oc

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 161

Metadata

Authors
Myatt, T. A., Johnston, S. L., Zuo, Z., Wand, M., Kebadze, T., Rudnick, S., & Milton, D. K.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2004-06-01
Volume
169
Issue
11
Pages
1187-1190
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2108489553
Cited by
161
References
6
FWCI
6.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of Airborne Rhinovirus and Its Relation to Outdoor Air Supply in Office Environments. https://app.cochat.ai/papers/10.1164/rccm.200306-760oc
The paper
Myatt, T. A., Johnston, S. L., Zuo, Z., Wand, M., Kebadze, T., Rudnick, S., & Milton, D. K. (2004). Detection of Airborne Rhinovirus and Its Relation to Outdoor Air Supply in Office Environments. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.200306-760oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.