Clinical Usefulness of Home Oximetry Compared with Polysomnography for Assessment of Sleep Apnea
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
The practical purpose of diagnostic assessment in most cases of obstructive sleep apnea is to predict which patients have symptoms that will improve on treatment. We measured the accuracy with which clinicians make this prediction using polysomnography compared with oximeter-based home monitoring. Patients referred to a sleep center with suspicion of symptomatic obstructive sleep apnea were randomized to have polysomnography or home monitoring. Patients with comorbidity or physiologic consequences of sleep apnea were excluded. Sleep specialists estimated the likelihood of success of treatment as greater than 50% (predicted success) or less than 50% (predicted failure) on the basis of clinical data and test results. All patients were treated for 4 weeks with autoadjusting continuous positive airway pressure. Success was defined as an increase greater than 1.0 in Sleep Apnea Quality of Life Index. Correct prediction rates were compared. Two hundred eighty-eight patients were enrolled. Initial patient characteristics, compliance, and improvement in quality of life at 4 weeks were not different in the two groups. The correct prediction rate was 0.61 with polysomnography and 0.64 with home monitoring (not significant). We conclude that the ability of physicians to predict the outcome of continuous positive airway treatment in individual patients is not significantly better with polysomnography than with home oximeter-based monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · PubMed · Cited by 33,716
The MOS 36-ltem Short-Form Health Survey (SF-36): I. Conceptual Framework and Item Selection
Ware, J. E., & Sherbourne, C. D. (1992) · Medical Care · doi:10.1097/00005650-199206000-00002 · Cited by 30,033 · cited 1×
“Patients completed the shortened, self-administered version (21) of the SAQLI just before and after treatment, as well as the SF-36 Health Survey (Medical Outcomes Trust, Inc., Boston, MA), a general health status instrument ( 22 ), and the Epworth Sleepiness Scale (23).”
MethodA New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Johns, M. W. (1991) · Sleep · doi:10.1093/sleep/14.6.540 · Cited by 17,364 · cited 3×
“They had lower mean AHI or RDI values than the rest of the patients, but there were no significant differences in pretreatment mean values for SAQLI or Epworth Sleepiness Scale.”
BackgroundMcNicholas, W. T., Strohl, K. P., White, D. P., Levy, P. A., Schmidt, W., Wheatley, J. R., Redline, S. S., Carley, D. W., Buysse, D. J., Young, T. B., et al. (1999) · PubMed · Cited by 3,665
Young, T., Evans, L., Finn, L., & Palta, M. (1997) · Sleep · doi:10.1093/sleep/20.9.705 · Cited by 1,765 · cited 1×
“Approximately 90% of people with the condition remain undiagnosed (3).”
BackgroundTHE MOS 36- ITEM SHORT FORM HEALTH SURVEY (SF- 36) CONCEPTUAL FRAMEWORK AND ITEM SELECTION
J.E.Jr., W., & Sherburne, C. D. (1992) · Cited by 1,586
Objective Measurement of Patterns of Nasal CPAP Use by Patients with Obstructive Sleep Apnea
Kribbs, N. B., Pack, A. I., Kline, L. R., Smith, P. L., Schwartz, A. R., Schubert, N. M., Redline, S., Henry, J. N., Getsy, J. E., & Dinges, D. F. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.4.887 · Cited by 1,339 · cited 1×
“Compliance was defined as greater than 4 hours/night of use (24) over the last 2 weeks of treatment.”
BackgroundJenkinson, C., Davies, R. J., Mullins, R., & Stradling, J. R. (1999) · The Lancet · doi:10.1016/s0140-6736(98)10532-9 · Cited by 826
Long-term Use of CPAP Therapy for Sleep Apnea/Hypopnea Syndrome
McARDLE, N., DEVEREUX, G., HEIDARNEJAD, H., ENGLEMAN, H. M., MACKAY, T. W., & DOUGLAS, N. J. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.4.9807111 · Cited by 820
Cited by
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
Obstructive Sleep Apnea Devices for Out-Of-Center (OOC) Testing: Technology Evaluation
Collop, N. A., Tracy, S. L., Kapur, V., Mehra, R., Kuhlmann, D., Fleishman, S. A., & Ojile, J. M. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1328 · Cited by 427
Mulgrew, A. T., Fox, N., Ayas, N. T., & Ryan, C. F. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-3-200702060-00004 · Cited by 368
Rosen, C. L., Auckley, D., Benca, R., Foldvary-Schaefer, N., Iber, C., Kapur, V., Rueschman, M., Zee, P., & Redline, S. (2012) · Sleep · doi:10.5665/sleep.1870 · Cited by 367
Diagnosis of Obstructive Sleep Apnea in Adults
McNicholas, W. T. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200708-118mg · Cited by 285
Association of Sleep-Disordered Breathing With Postoperative Complications
Hwang, D., Shakir, N., Limann, B., Sison, C., Kalra, S., Shulman, L., Souza, A. D. C., & Greenberg, H. (2008) · Chest · doi:10.1378/chest.07-1488 · Cited by 244
Masa, J. F., Corral, J., Pereira, R., Duran-Cantolla, J., Cabello, M., Hernandez-Blasco, L., Monasterio, C., Alonso, A., Chiner, E., Rubio, M., et al. (2011) · Thorax · doi:10.1136/thx.2010.152272 · Cited by 161
Diagnosis of Obstructive Sleep Apnea Syndrome and Its Outcomes With Home Portable Monitoring
de Oliveira, A. C. T., Martinez, D., Vasconcelos, L. F. T., Cadaval Gonçalves, S., do Carmo Lenz, M., Costa Fuchs, S., Gus, M., de Abreu-Silva, E. O., Beltrami Moreira, L., & Danni Fuchs, F. (2009) · Chest · doi:10.1378/chest.08-1859 · Cited by 129
An Economic Evaluation of Home Versus Laboratory-Based Diagnosis of Obstructive Sleep Apnea
Kim, R. D., Kapur, V. K., Redline-Bruch, J., Rueschman, M., Auckley, D. H., Benca, R. M., Foldvary-Schafer, N. R., Iber, C., Zee, P. C., Rosen, C. L., et al. (2015) · Sleep · doi:10.5665/sleep.4804 · Cited by 105
West, S. D. (2006) · Thorax · doi:10.1136/thx.2005.046300 · Cited by 93
Finan, P. H., Richards, J. M., Gamaldo, C. E., Han, D., Leoutsakos, J. M., Salas, R., Irwin, M. R., & Smith, M. T. (2016) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6262 · Cited by 90
“The automatic scoring algorithm (SP Auto) was guided by general staging rules consistent with the AASM scoring rules,8 with the following exceptions: (1) Four consecutive non-wake epochs are necessary to identify sleep onset in the first 5 minutes of recording; (2) If a wake period is identified within a block of REM…”
MethodNussbaumer, Y., Bloch, K. E., Genser, T., & Thurnheer, R. (2006) · Chest · doi:10.1378/chest.129.3.638 · Cited by 63
Effect of an ambulatory diagnostic and treatment programme in patients with sleep apnoea
Andreu, A. L., Chiner, E., Sancho-Chust, J. N., Pastor, E., Llombart, M., Gomez-Merino, E., Senent, C., & Barbé, F. (2012) · European Respiratory Journal · doi:10.1183/09031936.00013311 · Cited by 62
Comparability of pulse oximeters used in sleep medicine for the screening of OSA
Böhning, N., Schultheiß, B., Eilers, S., Penzel, T., Böhning, W., & Schmittendorf, E. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/7/001 · Cited by 35
Sharma, S., Mather, P., Efird, J. T., Kahn, D., Cheema, M., Rubin, S., Reeves, G., Bonita, R., Malloy, R., & Whellan, D. J. (2015) · JACC: Heart Failure · doi:10.1016/j.jchf.2015.04.015 · Cited by 31
Pataka, A., Kalamaras, G., Vlachogianni, E., & Argyropoulou, P. (2019) · Pulmonology · doi:10.1016/j.pulmoe.2018.10.004 · Cited by 12
“Our results support the argument that home monitoring may replace laboratory diagnosis and treatment of OSA in situations where access to sleep studies is not available, reducing costs and facilitating rapid initiation of CPAP treatment, especially in severe disease.(13,25,26) However, this may not be sufficient for a…”
ResultPatel, M. R., Alexander, T. H., & Davidson, T. M. (2007) · Operative Techniques in Otolaryngology-Head and Neck Surgery · doi:10.1016/j.otot.2007.01.005 · Cited by 8
Metadata
- Authors
- Whitelaw, W. A., Brant, R. F., & Flemons, W. W.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-01-15
- Volume
- 171
- Issue
- 2
- Pages
- 188-193
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W1969317592
- Cited by
- 173
- References
- 37
- FWCI
- 6.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.