Effects of Different Ventilator Settings on Sleep and Inspiratory Effort in Patients with Neuromuscular Disease
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Patients with neuromuscular disease (NMD) who require long-term ventilation normally have the ventilation set using empirical daytime parameters. We evaluated arterial blood gases (ABG), breathing pattern, respiratory muscle function, and sleep architecture during ventilation with two noninvasive Pressure Support Ventilation (nPSV) settings in nine patients with NMD. The two settings were randomly applied: the usual (US), with the nPSV setting titrated on simple clinical parameters, and the physiological (PHYS), tailored to the patient's respiratory effort. During wakefulness, nPSV significantly improved ABG and minute ventilation and reduced the diaphragmatic pressure-time product (PTPdi/breath), independently of the type of setting (PTPdi/breath spontaneous breathing 5.7 +/- 2.4, US 3.2 +/- 2, PHYS 3.6 +/- 1.6 cm H2O . seconds(-1), p < 0.001). However, during sleep, PHY nPSV resulted in a significant improvement of gas exchange, sleep efficiency (71.7% +/- 14 US vs. 80.6% +/- 8.3 PHYS, p < 0.01) and % of REM sleep (9.1% +/- 7 US vs. 17.3% +/- 5.4 PHYS, p < 0.01). This improvement was significantly correlated with the reduction in ineffective efforts. In NMD, nPSV is effective in improving daytime ABG and in unloading inspiratory muscles independently of whether it is set on the basis of the patient's comfort or the patient's respiratory mechanics. However, PHYS was associated with better sleep architecture and nighttime gas exchange.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rechtschaffen, A. (1968) · Medical Entomology and Zoology · Cited by 12,675
A simple method for assessing the validity of the esophageal balloon technique.
Baydur, A., BEHRAKIS, P. K., Zin, W. A., Jaeger, M., & Milic‐Emili, J. (1982) · PubMed · doi:10.1164/arrd.1982.126.5.788 · Cited by 1,076
Physical Properties of Human Lungs Measured During Spontaneous Respiration
Mead, J., & Whittenberger, J. L. (1953) · Journal of Applied Physiology · doi:10.1152/jappl.1953.5.12.779 · Cited by 729
Appendini, L., Patessio, A., Zanaboni, S., Carone, M., Gukov, B., Donner, C. F., & Rossi, A. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.5.8173743 · Cited by 515
Meecham Jones, D. J., Paul, E. A., Jones, P. W., & Wedzicha, J. A. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.2.7633704 · Cited by 479
Clini, E., Sturani, C., Rossi, A., Viaggi, S., Corrado, A., Donner, C. F., & Ambrosino, N. (2002) · European Respiratory Journal · doi:10.1183/09031936.02.02162001 · Cited by 447
Jubran, A., van de Graaff, W. B., & Tobin, M. J. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.1.7599811 · Cited by 338
Effect of Ventilator Mode on Sleep Quality in Critically Ill Patients
Parthasarathy, S., & Tobin, M. J. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200209-999oc · Cited by 324
Strumpf, D. A., Millman, R. P., Carlisle, C. C., Grattan, L. M., Ryan, S. M., Erickson, A. D., & Hill, N. S. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.6.1234 · Cited by 272
Cited by
Patient-ventilator asynchrony during assisted mechanical ventilation
Thille, A. W., Rodriguez, P., Cabello, B., Lellouche, F., & Brochard, L. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0301-8 · Cited by 930
Asynchronies during mechanical ventilation are associated with mortality
Blanch, L., Villagra, A., Sales, B., Montanya, J., Lucangelo, U., Luján, M., García-Esquirol, O., Chacón, E., Estruga, A., Oliva, J. C., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3692-6 · Cited by 539
NPPV Titration Task Force of the American Academy of Sleep Medicine, Berry, R. B., Chediak, A., Brown, L. K., Finder, J., Gozal, D., Iber, C., Kushida, C. A., Morgenthaler, T., Rowley, J. A., et al. (2010) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27941 · Cited by 315
Bosma, K., Ferreyra, G., Ambrogio, C., Pasero, D., Mirabella, L., Braghiroli, A., Appendini, L., Mascia, L., & Ranieri, V. M. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000260055.64235.7c · Cited by 300
Clusters of ineffective efforts during mechanical ventilation: impact on outcome
Vaporidi, K., Babalis, D., Chytas, A., Lilitsis, E., Kondili, E., Amargianitakis, V., Chouvarda, I., Maglaveras, N., & Georgopoulos, D. (2017) · Intensive Care Medicine · doi:10.1007/s00134-016-4593-z · Cited by 184
Campo, F. R., Drouot, X., Thille, A. W., Galia, F., Cabello, B., dʼOrtho, M.-P., & Brochard, L. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181bc8243 · Cited by 179
“Additionally, poor sleep quality has been reported during NIV (11).”
BackgroundGonzalez-Bermejo, J., Perrin, C., Janssens, J. P., Pepin, J. L., Mroue, G., Léger, P., Langevin, B., Rouault, S., Rabec, C., Rodenstein, D., et al. (2012) · Thorax · doi:10.1136/thx.2010.142653 · Cited by 176
Sleep in the intensive care unit
Drouot, X., Cabello, B., d’Ortho, M.-P., & Brochard, L. (2008) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2007.11.004 · Cited by 165
Long-Term Ventilation in Neuromuscular Patients: Review of Concerns, Beliefs, and Ethical Dilemmas
Crimi, C., Pierucci, P., Carlucci, A., Cortegiani, A., & Gregoretti, C. (2019) · Respiration · doi:10.1159/000495941 · Cited by 46
Metadata
- Authors
- Fanfulla, F., Delmastro, M., Berardinelli, A., Lupo, N. D., & Nava, S.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-09-01
- Volume
- 172
- Issue
- 5
- Pages
- 619-624
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W1975797644
- Cited by
- 184
- References
- 30
- FWCI
- 9.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.