Association of Indoor Nitrogen Dioxide Exposure with Respiratory Symptoms in Children with Asthma
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
RATIONALE: Chronic exposure to indoor nitrogen dioxide (NO2) is a public health concern. Over half of U.S. households have a source of NO2, and experimental data suggest potential for adverse respiratory effects. OBJECTIVE: To examine associations of indoor NO2 exposure with respiratory symptoms among children with asthma. METHODS: NO2 was measured using Palmes tubes, and respiratory symptoms in the month before sampling were collected during home interviews of mothers of 728 children with active asthma. All were younger than 12 yr, lived at the sampled home for at least 2 mo, and had asthma symptoms or used maintenance medication within the previous year. MEASUREMENTS: Respiratory symptoms (wheeze, persistent cough, shortness of breath, chest tightness). RESULTS: Mean (SD) NO2 was 8.6 (9.1) ppb in homes with electric ranges and 25.9 (18.1) ppb in homes with gas stoves. In models stratified by housing type (a factor associated with socioeconomic status), gas stove presence and elevated NO2 were each significantly associated with respiratory symptoms, controlling for age, ethnicity, medication, mold/mildew, water leaks, and season of sampling. Among children in multifamily housing, exposure to gas stoves increased likelihood of wheeze (odds ratio [OR], 2.27; 95% confidence interval [95% CI], 1.15, 4.47), shortness of breath (OR, 2.33; 95% CI, 1.12, 5.06), and chest tightness (OR, 4.34; 95% CI, 1.76, 10.69), whereas each 20-ppb increase in NO2 increased both likelihood of any wheeze (OR, 1.52; 95% CI, 1.04, 2.21) or chest tightness (OR, 1.61; 95% CI, 1.04, 2.49), and days of wheeze (rate ratio (RR), 1.33; 95% CI, 1.05, 1.68) or chest tightness (RR, 1.51; 95% CI, 1.18, 1.91). CONCLUSION: Exposure to indoor NO2 at levels well below the Environmental Protection Agency outdoor standard (53 ppb) is associated with respiratory symptoms among children with asthma in multifamily housing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Personal sampler for nitrogen dioxide
PALMES, E. D., GUNNISON, A. F., DiMATTIO, J., & TOMCZYK, C. (1976) · American Industrial Hygiene Association Journal · doi:10.1080/0002889768507522 · Cited by 514 · cited 1×
“NO2 was measured in each home using a Palmes tube (31) placed in the main living area for 10 to 14 d after the enrollment visit.”
MethodPersonal exposure to nitrogen dioxide (NO2) and the severity of virus-induced asthma in children
Chauhan, A., Inskip, H. M., Linaker, C. H., Smith, S., Schreiber, J., Johnston, S. L., & Holgate, S. T. (2003) · The Lancet · doi:10.1016/s0140-6736(03)13582-9 · Cited by 346 · cited 1×
“In a study of 114 children with asthma in England, the authors investigated whether NO2 exposure before viral infections could potentiate an asthmatic response (21, 22).”
BackgroundBelanger, K. (2003) · American Journal of Epidemiology · doi:10.1093/aje/kwg148 · Cited by 232 · cited 3×
“Populations studied have also varied and include healthy children (4, 5, 12–15) and infants (16–19), as well as children with asthma (4, 5, 20–23) and infants at risk for developing asthma (24, 25).”
BackgroundSelf-citationChildhood Asthma and the Indoor Environment
Dekker, C., Dales, R., Bartlett, S., Brunekreef, B., & Zwanenburg, H. (1991) · Chest · doi:10.1378/chest.100.4.922 · Cited by 208
Synthesis of Environmental Evidence: Nitrogen Dioxide Epidemiology Studies
Hasselblad, V., Eddy, D. M., & Kotchmar, D. J. (1992) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1992.10467018 · Cited by 202
Effect of outdoor and indoor nitrogen dioxide on respiratory symptoms in schoolchildren
Shima, M., & Adachi, M. (2000) · International Journal of Epidemiology · doi:10.1093/ije/29.5.862 · Cited by 171
Inhalation of 0.30 ppm nitrogen dioxide potentiates exercise-induced bronchospasm in asthmatics.
Bauer, M. A., Utell, M. J., Morrow, P. E., Speers, D. M., & Gibb, F. R. (1986) · PubMed · doi:10.1164/arrd.1986.134.6.1203 · Cited by 165
Gent, J. F., Ren, P., Belanger, K., Triche, E., Bracken, M. B., Holford, T. R., & Leaderer, B. P. (2002) · Environmental Health Perspectives · doi:10.1289/ehp.021100781 · Cited by 161 · cited 2×
“The Yale Childhood Asthma Study (24, 25, 29) enrolled 1,002 families who had a newborn infant and an older child with physician-diagnosed asthma.”
BackgroundSelf-citationRespiratory Symptoms in Children and Indoor Exposure to Nitrogen Dioxide and Gas Stoves
GARRETT, M. H., HOOPER, M. A., HOOPER, B. M., & ABRAMSON, M. J. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.3.9701084 · Cited by 158 · cited 1×
“Garrett and colleagues (43) prospectively investigated 148 Australian children, including 53 children with asthma and 88 children with atopy.”
BackgroundImpact of Residential Nitrogen Dioxide Exposure on Personal Exposure: An International Study
Levy, J. I. (1998) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1998.10463704 · Cited by 136
Cited by
Highly ordered nanowire arrays on plastic substrates for ultrasensitive flexible chemical sensors
McAlpine, M. C., Ahmad, H., Wang, D., & Heath, J. R. (2007) · Nature Materials · doi:10.1038/nmat1891 · Cited by 959
Outdoor Air Pollution: Nitrogen Dioxide, Sulfur Dioxide, and Carbon Monoxide Health Effects
Chen, T.-M., Kuschner, W. G., Gokhale, J., & Shofer, S. (2007) · The American Journal of the Medical Sciences · doi:10.1097/maj.0b013e31803b900f · Cited by 729
The health effects of nonindustrial indoor air pollution
Bernstein, J. A., Alexis, N., Bacchus, H., Bernstein, I. L., Fritz, P., Horner, E., Li, N., Mason, S., Nel, A., Oullette, J., et al. (2008) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2007.10.045 · Cited by 574
Indoor Exposure to Selected Air Pollutants in the Home Environment: A Systematic Review
Vardoulakis, S., Giagloglou, E., Steinle, S., Davis, A., Sleeuwenhoek, A., Galea, K. S., Dixon, K., & Crawford, J. O. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17238972 · Cited by 545
Kanchongkittiphon, W., Mendell, M. J., Gaffin, J. M., Wang, G., & Phipatanakul, W. (2015) · Environmental Health Perspectives · doi:10.1289/ehp.1307922 · Cited by 414
A review on human health perspective of air pollution with respect to allergies and asthma
Kim, K.-H., Jahan, S. A., & Kabir, E. (2013) · Environment International · doi:10.1016/j.envint.2013.05.007 · Cited by 374
Respiratory health and indoor air pollutants based on quantitative exposure assessments
Hulin, M., Simoni, M., Viegi, G., & Annesi-Maesano, I. (2012) · European Respiratory Journal · doi:10.1183/09031936.00159011 · Cited by 267
Acute respiratory health effects of air pollution on children with asthma in US inner cities
O'Connor, G. T., Neas, L., Vaughn, B., Kattan, M., Mitchell, H., Crain, E. F., Evans, R., Gruchalla, R., Morgan, W., Stout, J., et al. (2008) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2008.02.020 · Cited by 264
Dannemiller, K. C., Gent, J. F., Leaderer, B. P., & Peccia, J. (2016) · Indoor Air · doi:10.1111/ina.12205 · Cited by 197
“, 1997), single or multifamily homes (Belanger et al., 2006), visible mold (Mendell et al.”
BackgroundSelf-citationCrocker, D. D., Kinyota, S., Dumitru, G. G., Ligon, C. B., Herman, E. J., Ferdinands, J. M., Hopkins, D. P., Lawrence, B. M., & Sipe, T. A. (2011) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2011.05.012 · Cited by 183
Hansel, N. N., Breysse, P. N., McCormack, M. C., Matsui, E. C., Curtin-Brosnan, J., Williams, D. L., Moore, J. L., Cuhran, J. L., & Diette, G. B. (2008) · Environmental Health Perspectives · doi:10.1289/ehp.11349 · Cited by 175
“Studies done in subjects with asthma have suggested that higher indoor NO2 concentrations lead to increased asthma symptoms; however, results have not been consistent across subpopulations (Belanger et al. 2006; Garrett et al. 1998; Hasselblad et al. 1992; Kattan et al. 2007; Nitschke et al. 2006; Shima and Adachi 200…”
BackgroundResultInfluentialThe respiratory health effects of nitrogen dioxide in children with asthma
Gillespie-Bennett, J., Pierse, N., Wickens, K., Crane, J., Howden-Chapman, P., & and the Housing Heating and Health Study Research Team (2011) · European Respiratory Journal · doi:10.1183/09031936.00115409 · Cited by 98
Gillespie-Bennett, J., Pierse, N., Wickens, K., Crane, J., Nicholls, S., Shields, D., Boulic, M., Viggers, H., Baker, M., Woodward, A., et al. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2008.00554.x · Cited by 36
Pettit, T., Irga, P. J., Surawski, N. C., & Torpy, F. R. (2019) · Atmosphere · doi:10.3390/atmos10120801 · Cited by 35
Metadata
- Authors
- Belanger, K., Gent, J. F., Triche, E. W., Bracken, M. B., & Leaderer, B. P.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-02-01
- Volume
- 173
- Issue
- 3
- Pages
- 297-303
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2082238102
- Cited by
- 172
- References
- 35
- FWCI
- 5.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.