The DOI matches its Crossref record.
Airway deposition and airway effects of antiasthma drugs delivered from metered-dose inhalers
Open accessAbstract
Many different metered-dose inhalation devices are becoming available for the treatment of airway diseases. Each of these inhalers differs in its delivery characteristics. An assessment of the efficacy of drug delivery by these inhalers is essential, in view of their therapeutic use. A review of the literature on the relationship between airway deposition and airway effects of drugs delivered from metered-dose inhalers is presented. Nebulizers or spacers are not discussed. The effect of an inhaler depends on the characteristics of the inhaler and the inhalation manoeuvre performed by the patient. This review focuses on the influence of inhaler characteristics on the airway deposition and airway effects. Data from several studies show that there is a significant relationship between the amount of drug deposited in the airways and the airway effects of the drug. Studies on the relationship between airway deposition and airway effect have been troubled by methodological problems, such as the absence of multiple dose comparisons and the difficulty in obtaining steep dose-response curves. The techniques for measuring airway deposition of inhaled drugs, namely the scintigraphic and the pharmacokinetic method, are discussed and compared. The appropriate use of these techniques can help to define and compare the drug delivery characteristics of different devices, thus enabling inhaled therapy to be optimized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Physiological changes in respiratory function associated with ageing
Janssens, J.-P., Pache, J. C., & Nicod, L. P. (1999) · European Respiratory Journal · doi:10.1034/j.1399-3003.1999.13a36.x · Cited by 801
Regional Lung Deposition and Bronchodilator Response as a Function of β 2 -Agonist Particle Size
Usmani, O. S., Biddiscombe, M. F., & Barnes, P. J. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200410-1414oc · Cited by 578
Evolution of dry powder inhaler design, formulation, and performance
NEWMAN, S. P., & BUSSE, W. W. (2002) · Respiratory Medicine · doi:10.1053/rmed.2001.1276 · Cited by 340
Self-citationChoosing inhaler devices for people with asthma: Current knowledge and outstanding research needs
Haughney, J., Price, D., Barnes, N. C., Virchow, J. C., Roche, N., & Chrystyn, H. (2010) · Respiratory Medicine · doi:10.1016/j.rmed.2010.04.012 · Cited by 190
Metadata
- Authors
- Pauwels, R., Newman, S., & Borgstrom, L.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1997-09-01
- Volume
- 10
- Issue
- 9
- Pages
- 2127-2138
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2163347392
- Cited by
- 198
- References
- 0
- FWCI
- 9.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Airway deposition and airway effects of antiasthma drugs delivered from metered-dose inhalers. https://app.cochat.ai/papers/10.1183/09031936.97.10092127
- The paper
- Pauwels, R., Newman, S., & Borgstrom, L. (1997). Airway deposition and airway effects of antiasthma drugs delivered from metered-dose inhalers. European Respiratory Journal. https://doi.org/10.1183/09031936.97.10092127
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.