Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 260

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Influence of an Endotracheal Tube with Polyurethane Cuff and Subglottic Secretion Drainage on Pneumonia

Lorente, Leonardo, Lecuona, María, Jiménez, Alejandro, Mora, María L., Sierra, Antonio·2007·American Journal of Respiratory and Critical Care Medicine

Abstract

RATIONALE: Subglottic secretion drainage (SSD) appears to be effective in preventing ventilator-associated pneumonia (VAP), primarily by reducing early-onset pneumonia; but it may not prevent late-onset pneumonia. We tested the hypothesis using an endotracheal tube incorporating an ultrathin polyurethane cuff (which reduces channel formation and fluid leakage from the subglottic area), in addition to an SSD lumen, which would reduce the incidence of late-onset VAP. OBJECTIVES: To compare the incidence of VAP, using an endotracheal tube with polyurethane cuff and subglottic secretion drainage (ETT-PUC-SSD) versus a conventional endotracheal tube (ETT-C) with polyvinyl cuff, without subglottic secretion drainage. METHODS: Clinical randomized trial in a 24-bed medical-surgical intensive care unit. Patients expected to require mechanical ventilation for more than 24 hours were randomly assigned to one of two groups: one was ventilated with ETT-PUC-SSD and the other with ETT-C. MEASUREMENTS AND MAIN RESULTS: Tracheal aspirate samples were obtained during endotracheal intubation, then twice per week and finally on extubation. VAP was found in 31 of 140 (22.1%) patients in the ETT-C group and in 11 of 140 (7.9%) in the ETT-PUC-SSD group (P = 0.001). Cox regression analysis showed ETT-C as a risk factor for global VAP (hazard ratio [HR], 3.3; 95% confidence interval [CI], 1.66-6.67; P = 0.001), early-onset VAP (HR, 3.3; 95% CI, 1.19-9.09; P = 0.02), and late-onset VAP (HR, 3.5; 95% CI, 1.34-9.01; P = 0.01). CONCLUSIONS: The use of an endotracheal tube with polyurethane cuff and subglottic secretion drainage helps prevent early- and late-onset VAP. Clinical trial registered with www.clinicaltrials.gov (NCT 00475579).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.200705-761oc

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 260

Metadata

Authors
Lorente, L., Lecuona, M., Jiménez, A., Mora, M. L., & Sierra, A.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2007-12-01
Volume
176
Issue
11
Pages
1079-1083
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2168365921
Cited by
260
References
19
FWCI
14.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Influence of an Endotracheal Tube with Polyurethane Cuff and Subglottic Secretion Drainage on Pneumonia. https://app.cochat.ai/papers/10.1164/rccm.200705-761oc
The paper
Lorente, L., Lecuona, M., Jiménez, A., Mora, M. L., & Sierra, A. (2007). Influence of an Endotracheal Tube with Polyurethane Cuff and Subglottic Secretion Drainage on Pneumonia. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.200705-761oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.