Intermittent Subglottic Secretion Drainage and Ventilator-associated Pneumonia: A Multicenter Trial
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
RATIONALE: Ventilator-associated pneumonia (VAP) causes substantial morbidity and mortality. The influence of subglottic secretion drainage (SSD) in preventing VAP remains controversial. OBJECTIVES: To determine whether SSD reduces the overall incidence of microbiologically confirmed VAP. METHODS: Randomized controlled clinical trial conducted at four French centers. A total of 333 adult patients intubated with a tracheal tube allowing drainage of subglottic secretions and expected to require mechanical ventilation for ≥48 hours was included. Patients were randomly assigned to undergo intermittent SSD (n = 169) or not (n = 164). MEASUREMENTS AND MAIN RESULTS: Primary outcome was the overall incidence of VAP based on quantitative culture of distal pulmonary samplings performed after each clinical suspicion. Other outcomes included incidence of early- and late-onset VAP, duration of mechanical ventilation, and hospital mortality. Microbiologically confirmed VAP occurred in 67 patients, 25 of 169 (14.8%) in the SSD group and 42 of 164 (25.6%) in the control group (P = 0.02), yielding a relative risk reduction of 42.2% (95% confidential interval, 10.4-63.1%). Using the Day 5 threshold, the beneficial effect of SSD in reducing VAP was observed in both early-onset VAP (2 of 169 [1.2%] patients undergoing SSD vs. 10 of 164 [6.1%] control patients; P = 0.02) and late-onset VAP (23 of 126 [18.6%] patients undergoing SSD vs. 32 of 97 [33.0%] control patients; P = 0.01). VAP was clinically suspected at least once in 51 of 169 (30.2%) patients undergoing SSD and 60 of 164 (36.6%) control patients (P = 0.25). No significant between-group differences were observed in duration of mechanical ventilation and hospital mortality. CONCLUSIONS: Subglottic secretion drainage during mechanical ventilation results in a significant reduction in VAP, including late-onset VAP. Clinical trial registered with www.clinicaltrials.gov (NCT00219661).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200405-644st · Cited by 5,877
Ventilator-associated Pneumonia
Chastre, J., & Fagon, J.-Y. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.7.2105078 · Cited by 2,812
(2004) · PsycEXTRA Dataset · doi:10.1037/e548652006-001 · Cited by 1,305 · cited 1×
“and Canadian guidelines in 2003 and 2004 (14, 15).”
BackgroundVentilator-associated Pneumonia Caused by Potentially Drug-resistant Bacteria
TROUILLET, J.-L., CHASTRE, J., VUAGNAT, A., JOLY-GUILLOU, M.-L., COMBAUX, D., DOMBRET, M.-C., & GIBERT, C. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.2.9705064 · Cited by 885 · cited 2×
“Confirmation of pneumonia required a positive quantitative culture of either a protected telescoping catheter sample (25) or bronchoalveolar lavage fluid (26).”
BackgroundPneumonia in intubated patients: role of respiratory airway care.
Rello, J., Soñora, R., Jubert, P., Artigas, A., Rué, M., & Vallés, J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.1.8680665 · Cited by 703 · cited 1×
“In two singlecenter randomized controlled trials (7, 8) and one observational study (9), SSD reduced the incidence of VAP.”
BackgroundLeakage of fluid past the tracheal tube cuff in a benchtop model
Young, P., Rollinson, M., Downward, G., & Henderson, S. J. (1997) · British Journal of Anaesthesia · doi:10.1093/bja/78.5.557 · Cited by 629
Continuous Aspiration of Subglottic Secretions in Preventing Ventilator-Associated Pneumonia
Valles, J., Artigas, A., Rello, J., Bonsoms, N., Fontanals, D., Blanch, L., Fernandez, R., Baigorri, F., & Mestre, J. (1995) · Annals of Internal Medicine · doi:10.7326/0003-4819-122-3-199502010-00004 · Cited by 549 · cited 3×
“Reporting of these potential confounding factors was limited in previously published studies (7, 8, 12).”
BackgroundResultEvidence-Based Clinical Practice Guideline for the Prevention of Ventilator-Associated Pneumonia
Dodek, P., Keenan, S., Cook, D., Heyland, D., Jacka, M., Hand, L., Muscedere, J., Foster, D., Mehta, N., Hall, R., et al. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-141-4-200408170-00011 · Cited by 546
Kollef, M. H. (2008) · JAMA · doi:10.1001/jama.300.7.805 · Cited by 479 · cited 1×
“However, many previous studies of other measures used to prevent VAP, including endotracheal tube with a polyurethane cuff (28), oral decontamination with chlorhexidine (32), or silver-coated endotracheal tubes (33), failed to demonstrate a significant reduction in mortality associated with the reduction in VAP.”
ResultOral Decontamination with Chlorhexidine Reduces the Incidence of Ventilator-associated Pneumonia
Koeman, M., van der Ven, A. J. A. M., Hak, E., Joore, H. C. A., Kaasjager, K., de Smet, A. G. A., Ramsay, G., Dormans, T. P. J., Aarts, L. P. H. J., de Bel, E. E., et al. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200505-820oc · Cited by 414 · cited 1×
“However, many previous studies of other measures used to prevent VAP, including endotracheal tube with a polyurethane cuff (28), oral decontamination with chlorhexidine (32), or silver-coated endotracheal tubes (33), failed to demonstrate a significant reduction in mortality associated with the reduction in VAP.”
Result
Cited by
Ventilator-associated pneumonia in adults: a narrative review
Papazian, L., Klompas, M., & Luyt, C.-E. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-05980-0 · Cited by 1,010
Melsen, W. G., Rovers, M. M., Groenwold, R. H., Bergmans, D. C., Camus, C., Bauer, T. T., Hanisch, E. W., Klarin, B., Koeman, M., Krueger, W. A., et al. (2013) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(13)70081-1 · Cited by 854
Self-citationStrategies to Prevent Ventilator-Associated Pneumonia in Acute Care Hospitals: 2014 Update
Klompas, M., Branson, R., Eichenwald, E. C., Greene, L. R., Howell, M. D., Lee, G., Magill, S. S., Maragakis, L. L., Priebe, G. P., Speck, K., et al. (2014) · Infection Control & Hospital Epidemiology · doi:10.1086/677144 · Cited by 427
Klompas, M., Branson, R., Cawcutt, K., Crist, M., Eichenwald, E. C., Greene, L. R., Lee, G., Maragakis, L. L., Powell, K., Priebe, G. P., et al. (2022) · Infection Control & Hospital Epidemiology · doi:10.1017/ice.2022.88 · Cited by 402
Muscedere, J., Rewa, O., Mckechnie, K., Jiang, X., Laporta, D., & Heyland, D. K. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e318218a4d9 · Cited by 311
Shander, A., Fleisher, L. A., Barie, P. S., Bigatello, L. M., Sladen, R. N., & Watson, C. B. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e31821f0522 · Cited by 272
Subglottic secretion drainage for preventing ventilator associated pneumonia: A meta-analysis
Frost, S. A., Azeem, A., Alexandrou, E., Tam, V., Murphy, J. K., Hunt, L., O’Regan, W., & Hillman, K. M. (2013) · Australian Critical Care · doi:10.1016/j.aucc.2013.03.003 · Cited by 256
Melsen, W. G., Rovers, M. M., Koeman, M., & Bonten, M. J. M. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182281f33 · Cited by 209
Use of Silver in the Prevention and Treatment of Infections: Silver Review
Politano, A. D., Campbell, K. T., Rosenberger, L. H., & Sawyer, R. G. (2013) · Surgical Infections · doi:10.1089/sur.2011.097 · Cited by 204
Strategies to Prevent Ventilator-Associated Pneumonia in Acute Care Hospitals: 2014 Update
Klompas, M., Branson, R., Eichenwald, E. C., Greene, L. R., Howell, M. D., Lee, G., Magill, S. S., L. Maragakis, L., P. Priebe, G., Speck, K., et al. (2014) · Infection Control & Hospital Epidemiology · doi:10.1017/s0899823x00193894 · Cited by 196
Lung Injury and Acute Respiratory Distress Syndrome After Cardiac Surgery
Stephens, R. S., Shah, A. S., & Whitman, G. J. R. (2013) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2012.10.024 · Cited by 181
“Endotracheal tubes that permit intermittent drainage of subglottic secretions may also decrease the rate of VAP [45].”
Background
Metadata
- Authors
- Lacherade, J.-C., De Jonghe, B., Guezennec, P., Debbat, K., Hayon, J., Monsel, A., Fangio, P., Appere de Vecchi, C., Ramaut, C., Outin, H., & Bastuji-Garin, S.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-10-01
- Volume
- 182
- Issue
- 7
- Pages
- 910-917
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2133328161
- Cited by
- 187
- References
- 37
- FWCI
- 15.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.