Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 284

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Routine Use of the Confusion Assessment Method for the Intensive Care Unit: A Multicenter Study

Open access
van Eijk, Maarten M., van den Boogaard, Mark, van Marum, Rob J., Benner, Paul, Eikelenboom, Piet, Honing, Marina L., van der Hoven, Ben, Horn, Janneke, Izaks, Gerbrand J., Kalf, Annette, Karakus, Attila, Klijn, Ine A., Kuiper, Michael A., de Leeuw, Frank-Erik, de Man, Tjarda, van der Mast, Roos C., Osse, Robert-Jan, de Rooij, Sophia E., Spronk, Peter E., van der Voort, Peter H., van Gool, Willem A., Slooter, Arjen J. · 2011 · American Journal of Respiratory and Critical Care Medicine

Abstract

RATIONALE: Delirium is often unrecognized in ICU patients and associated with poor outcome. Screening for ICU delirium is recommended by several medical organizations to improve early diagnosis and treatment. The Confusion Assessment Method for the ICU (CAM-ICU) has high sensitivity and specificity for delirium when administered by research nurses. However, test characteristics of the CAM-ICU as performed in routine practice are unclear. OBJECTIVES: To investigate the diagnostic value of the CAM-ICU in daily practice. METHODS: Teams of three delirium experts including psychiatrists, geriatricians, and neurologists visited 10 ICUs twice. Based on cognitive examination, inspection of medical files, and Diagnostic and Statistic Manual of Mental Disorders, 4th edition, Text Revision criteria for delirium, the expert teams classified patients as awake and not delirious, delirious, or comatose. This served as a gold standard to which the CAM-ICU as performed by the bedside ICU-nurses was compared. Assessors were unaware of each other's conclusions. MEASUREMENTS AND MAIN RESULTS: Fifteen delirium experts assessed 282 patients of whom 101 (36%) were comatose and excluded. In the remaining 181 (64%) patients, the CAM-ICU had a sensitivity of 47% (95% confidence interval [CI], 35%-58%); specificity of 98% (95% CI, 93%-100%); positive predictive value of 95% (95% CI, 80%-99%); and negative predictive value of 72% (95% CI, 64%-79%). The positive likelihood ratio was 24.7 (95% CI, 6.1-100) and the negative likelihood ratio was 0.5 (95% CI, 0.4-0.8). CONCLUSIONS: Specificity of the CAM-ICU as performed in routine practice seems to be high but sensitivity is low. This hampers early detection of delirium by the CAM-ICU.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/rccm.201101-0065oc

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 284

Metadata

Authors
van Eijk, M. M., van den Boogaard, M., van Marum, R. J., Benner, P., Eikelenboom, P., Honing, M. L., van der Hoven, B., Horn, J., Izaks, G. J., Kalf, A., Karakus, A., Klijn, I. A., Kuiper, M. A., de Leeuw, F.-E., de Man, T., van der Mast, R. C., Osse, R.-J., de Rooij, S. E., Spronk, P. E., van der Voort, P. H., van Gool, W. A., & Slooter, A. J.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2011-08-01
Volume
184
Issue
3
Pages
340-344
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2115957615
Cited by
284
References
26
FWCI
19.75
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Routine Use of the Confusion Assessment Method for the Intensive Care Unit: A Multicenter Study. https://app.cochat.ai/papers/10.1164/rccm.201101-0065oc
The paper
van Eijk, M. M., van den Boogaard, M., van Marum, R. J., Benner, P., Eikelenboom, P., Honing, M. L., van der Hoven, B., Horn, J., Izaks, G. J., Kalf, A., Karakus, A., Klijn, I. A., Kuiper, M. A., de Leeuw, F.-E., de Man, T., van der Mast, R. C., Osse, R.-J., de Rooij, S. E., Spronk, P. E., . . . Slooter, A. J. (2011). Routine Use of the Confusion Assessment Method for the Intensive Care Unit: A Multicenter Study. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.201101-0065oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.