Routine Use of the Confusion Assessment Method for the Intensive Care Unit: A Multicenter Study
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
RATIONALE: Delirium is often unrecognized in ICU patients and associated with poor outcome. Screening for ICU delirium is recommended by several medical organizations to improve early diagnosis and treatment. The Confusion Assessment Method for the ICU (CAM-ICU) has high sensitivity and specificity for delirium when administered by research nurses. However, test characteristics of the CAM-ICU as performed in routine practice are unclear. OBJECTIVES: To investigate the diagnostic value of the CAM-ICU in daily practice. METHODS: Teams of three delirium experts including psychiatrists, geriatricians, and neurologists visited 10 ICUs twice. Based on cognitive examination, inspection of medical files, and Diagnostic and Statistic Manual of Mental Disorders, 4th edition, Text Revision criteria for delirium, the expert teams classified patients as awake and not delirious, delirious, or comatose. This served as a gold standard to which the CAM-ICU as performed by the bedside ICU-nurses was compared. Assessors were unaware of each other's conclusions. MEASUREMENTS AND MAIN RESULTS: Fifteen delirium experts assessed 282 patients of whom 101 (36%) were comatose and excluded. In the remaining 181 (64%) patients, the CAM-ICU had a sensitivity of 47% (95% confidence interval [CI], 35%-58%); specificity of 98% (95% CI, 93%-100%); positive predictive value of 95% (95% CI, 80%-99%); and negative predictive value of 72% (95% CI, 64%-79%). The positive likelihood ratio was 24.7 (95% CI, 6.1-100) and the negative likelihood ratio was 0.5 (95% CI, 0.4-0.8). CONCLUSIONS: Specificity of the CAM-ICU as performed in routine practice seems to be high but sensitivity is low. This hampers early detection of delirium by the CAM-ICU.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnostic and Statistical Manual of Mental Disorders
Williams, J. B. W., & First, M. (2013) · Encyclopedia of Social Work · doi:10.1093/acrefore/9780199975839.013.104 · Cited by 109,519
Ely, E. W., Inouye, S. K., Bernard, G. R., Gordon, S., Francis, J., May, L., Truman, B., Speroff, T., Gautam, S., Margolin, R., et al. (2001) · JAMA · doi:10.1001/jama.286.21.2703 · Cited by 3,210
Delirium as a Predictor of Mortality in Mechanically Ventilated Patients in the Intensive Care Unit
Ely, E. W. (2004) · JAMA · doi:10.1001/jama.291.14.1753 · Cited by 3,073
Ely, E. W., Margolin, R., Francis, J., May, L., Truman, B., Dittus, R., Speroff, T., Gautam, S., Bernard, G. R., & Inouye, S. K. (2001) · Critical Care Medicine · doi:10.1097/00003246-200107000-00012 · Cited by 2,422
Witlox, J., Eurelings, L. S. M., de Jonghe, J. F. M., Kalisvaart, K. J., Eikelenboom, P., & van Gool, W. A. (2010) · JAMA · doi:10.1001/jama.2010.1013 · Cited by 1,960
Self-citationJacobi, J., Fraser, G. L., Coursin, D. B., Riker, R. R., Fontaine, D., Wittbrodt, E. T., Chalfin, D. B., Masica, M. F., Bjerke, H. S., Coplin, W. M., et al. (2002) · Critical Care Medicine · doi:10.1097/00003246-200201000-00020 · Cited by 1,895
Intensive Care Delirium Screening Checklist: evaluation of a new screening tool
Bergeron, N., Dubois, M.-J., Dumont, M., Dial, S., & Skrobik, Y. (2001) · Intensive Care Medicine · doi:10.1007/s001340100909 · Cited by 1,487
The impact of delirium in the intensive care unit on hospital length of stay
Ely, E., Gautam, S., Margolin, R., Francis, J., May, L., Speroff, T., Truman, B., Dittus, R., Bernard, G., & Inouye, S. (2001) · Intensive Care Medicine · doi:10.1007/s00134-001-1132-2 · Cited by 1,038
Incidence, risk factors and consequences of ICU delirium
Ouimet, S., Kavanagh, B. P., Gottfried, S. B., & Skrobik, Y. (2007) · Intensive Care Medicine · doi:10.1007/s00134-006-0399-8 · Cited by 972
Costs associated with delirium in mechanically ventilated patients*
Milbrandt, E. B., Deppen, S., Harrison, P. L., Shintani, A. K., Speroff, T., Stiles, R. A., Truman, B., Bernard, G. R., Dittus, R. S., & Ely, E. W. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000119429.16055.92 · Cited by 839
Cited by
Barr, J., Fraser, G. L., Puntillo, K., Ely, E. W., Gélinas, C., Dasta, J. F., Davidson, J. E., Devlin, J. W., Kress, J. P., Joffe, A. M., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182783b72 · Cited by 3,765
Sepsis-associated encephalopathy
Gofton, T. E., & Young, G. B. (2012) · Nature Reviews Neurology · doi:10.1038/nrneurol.2012.183 · Cited by 821
Su, X., Meng, Z.-T., Wu, X.-H., Cui, F., Li, H.-L., Wang, D.-X., Zhu, X., Zhu, S.-N., Maze, M., & Ma, D. (2016) · The Lancet · doi:10.1016/s0140-6736(16)30580-3 · Cited by 793
Gusmao-Flores, D., Salluh, J. I. F., Chalhub, R. Á., & Quarantini, L. C. (2012) · Critical Care · doi:10.1186/cc11407 · Cited by 574
A Systematic Review of Risk Factors for Delirium in the ICU*
Zaal, I. J., Devlin, J. W., Peelen, L. M., & Slooter, A. J. C. (2015) · Critical Care Medicine · doi:10.1097/ccm.0000000000000625 · Cited by 545
Self-citationBoogaard, M. V. D., Pickkers, P., Slooter, A. J. C., Kuiper, M. A., Spronk, P. E., Voort, P. H. J. V. D., Hoeven, J. G. V. D., Donders, R., Achterberg, T. V., & Schoonhoven, L. (2012) · BMJ · doi:10.1136/bmj.e420 · Cited by 447
Self-citationDelirium in critical illness: clinical manifestations, outcomes, and management
Stollings, J. L., Kotfis, K., Chanques, G., Pun, B. T., Pandharipande, P. P., & Ely, E. W. (2021) · Intensive Care Medicine · doi:10.1007/s00134-021-06503-1 · Cited by 446
van den Boogaard, M., Schoonhoven, L., Evers, A. W. M., van der Hoeven, J. G., van Achterberg, T., & Pickkers, P. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e31822e9fc9 · Cited by 361
The Sedation Practice in Intensive Care Evaluation (SPICE) Study Group investigators, Shehabi, Y., Chan, L., Kadiman, S., Alias, A., Ismail, W. N., Tan, M. A. T. I., Khoo, T. M., Ali, S. B., Saman, M. A., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-013-2830-2 · Cited by 355
Writing Group for the PReVENT Investigators, Simonis, F. D., Serpa Neto, A., Binnekade, J. M., Braber, A., Bruin, K. C. M., Determann, R. M., Goekoop, G.-J., Heidt, J., Horn, J., et al. (2018) · JAMA · doi:10.1001/jama.2018.14280 · Cited by 279
Self-citationDelirium in the ICU: an overview
Cavallazzi, R., Saad, M., & Marik, P. E. (2012) · Annals of Intensive Care · doi:10.1186/2110-5820-2-49 · Cited by 275
Benzodiazepine-associated delirium in critically ill adults
Zaal, I. J., Devlin, J. W., Hazelbag, M., Klein Klouwenberg, P. M. C., van der Kooi, A. W., Ong, D. S. Y., Cremer, O. L., Groenwold, R. H., & Slooter, A. J. C. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-4063-z · Cited by 246
Self-citationSepsis Associated Encephalopathy
Chaudhry, N., & Duggal, A. K. (2014) · Advances in Medicine · doi:10.1155/2014/762320 · Cited by 227
“CAMICU however has only about 41–47% sensitivity when used by regular ICU nurses, although the specificity was excellent (98%) [76, 77].”
Multinational development and validation of an early prediction model for delirium in ICU patients
Wassenaar, A., van den Boogaard, M., van Achterberg, T., Slooter, A. J. C., Kuiper, M. A., Hoogendoorn, M. E., Simons, K. S., Maseda, E., Pinto, N., Jones, C., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3777-2 · Cited by 219
Self-citationEmergence from general anaesthesia and evolution of delirium signs in the post-anaesthesia care unit
Card, E., Tomes, C., Lee, C., Wood, J., Nelson, D., Graves, A., Shintani, A., Ely, E. W., Hughes, C., & Pandharipande, P. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aeu442 · Cited by 211
Sedation and Analgesia in the Mechanically Ventilated Patient
Patel, S. B., & Kress, J. P. (2012) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201102-0273ci · Cited by 204
“However, van Eijk and colleagues demonstrated that although the CAM-ICU remains highly specific, the sensitivity decreases to almost half when used in a real-world setting (134).”
BackgroundWolters, A. E., van Dijk, D., Pasma, W., Cremer, O. L., Looije, M. F., de Lange, D. W., Veldhuijzen, D. S., & Slooter, A. J. (2014) · Critical Care · doi:10.1186/cc13929 · Cited by 198
“Secondly, the sensitivity of the CAM-ICU in daily practice may be low [7].”
BackgroundMethodSelf-citationWhitlock, E. L., Torres, B. A., Lin, N., Helsten, D. L., Nadelson, M. R., Mashour, G. A., & Avidan, M. S. (2014) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000028 · Cited by 192
Sharshar, T., Citerio, G., Andrews, P. J. D., Chieregato, A., Latronico, N., Menon, D. K., Puybasset, L., Sandroni, C., & Stevens, R. D. (2014) · Intensive Care Medicine · doi:10.1007/s00134-014-3214-y · Cited by 174
“and reliability of the two instruments when compared to a diagnostic gold standard (DSM) is mixed [4, 14, 56], as is their comparative accuracy [13, 58, 59].”
BackgroundChen, T.-J., Chung, Y.-W., Chang, H.-C. (., Chen, P.-Y., Wu, C.-R., Hsieh, S.-H., & Chiu, H.-Y. (2021) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2020.103782 · Cited by 164
Confusion assessment method: a systematic review and meta-analysis of diagnostic accuracy
Shi, Q., Warren, Saposnik, & MacDermid (2013) · Neuropsychiatric Disease and Treatment · doi:10.2147/ndt.s49520 · Cited by 160
Implementing Delirium Screening in the ICU: Secrets to Success
Brummel, N. E., Vasilevskis, E. E., Han, J. H., Boehm, L., Pun, B. T., & Ely, E. W. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31829a6f1e · Cited by 158
“It cannot be assumed, however, that this is always the case (50) and due diligence must be the rule and not the exception.”
BackgroundInfluential
Metadata
- Authors
- van Eijk, M. M., van den Boogaard, M., van Marum, R. J., Benner, P., Eikelenboom, P., Honing, M. L., van der Hoven, B., Horn, J., Izaks, G. J., Kalf, A., Karakus, A., Klijn, I. A., Kuiper, M. A., de Leeuw, F.-E., de Man, T., van der Mast, R. C., Osse, R.-J., de Rooij, S. E., Spronk, P. E., van der Voort, P. H., van Gool, W. A., & Slooter, A. J.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-08-01
- Volume
- 184
- Issue
- 3
- Pages
- 340-344
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2115957615
- Cited by
- 284
- References
- 26
- FWCI
- 19.75
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.