Influences of Spinal Anesthesia on Exercise Tolerance in Patients with Chronic Obstructive Pulmonary Disease
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
RATIONALE: Lower limb muscle dysfunction contributes to exercise intolerance in chronic obstructive pulmonary disease (COPD). We hypothesized that signaling from lower limb muscle group III/IV sensory afferents to the central motor command could be involved in premature cycling exercise termination in COPD. OBJECTIVES: To evaluate the effects of spinal anesthesia, which presumably inhibited central feedback from the lower limb muscle group III/IV sensory afferents on exercise tolerance and cardiorespiratory response during constant work-rate cycling exercise in patients with COPD. METHODS: In a crossover and double-blind randomized design, eight patients with COPD (FEV(1), 67 ± 8% predicted) completed a constant work-rate cycling exercise after sham (NaCl, interspinous L(3)-L(4)) or active (fentanyl 25 μg, intrathecal L(3)-L(4)) spinal anesthesia. MEASUREMENTS AND MAIN RESULTS: When compared with placebo, endurance time was significantly prolonged after spinal anesthesia with fentanyl (639 ± 87 s vs. 423 ± 38 s [mean ± SEM]; P = 0.01). Ventilation and respiratory rate were reduced at isotime points under the fentanyl condition, whereas ventilatory efficiency and dead space ventilation were improved. Patients exhibited less dynamic hyperinflation at isotime points with spinal anesthesia. Consequently, the rise in dyspnea was significantly flatter during the fentanyl condition than with placebo. CONCLUSIONS: Spinal anesthesia enhanced cycling exercise tolerance in patients with COPD, mostly by reducing ventilatory response and dyspnea during exercise; these effects were possibly mediated through the inhibition of group III/IV lower limb sensory muscle afferents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lung volumes and forced ventilatory flows
Quanjer, P. H., Tammeling, G. J., Cotes, J. E., Pedersen, O. F., Peslin, R., & Yernault, J.-C. (1993) · European Respiratory Journal · doi:10.1183/09041950.005s1693 · Cited by 5,318
Spinal and Supraspinal Factors in Human Muscle Fatigue
Gandevia, S. C. (2001) · Physiological Reviews · doi:10.1152/physrev.2001.81.4.1725 · Cited by 3,645
Development and first validation of the COPD Assessment Test
Jones, P. W., Harding, G., Berry, P., Wiklund, I., Chen, W.-H., & Kline Leidy, N. (2009) · European Respiratory Journal · doi:10.1183/09031936.00102509 · Cited by 3,198
Dynamic Hyperinflation and Exercise Intolerance in Chronic Obstructive Pulmonary Disease
O'DONNELL, D. E., REVILL, S. M., & WEBB, K. A. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.5.2012122 · Cited by 1,076
Casaburi, R., Patessio, A., Ioli, F., Zanaboni, S., Donner, C. F., & Wasserman, K. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/143.1.9 · Cited by 906
Effects of tiotropium on lung hyperinflation, dyspnoea and exercise tolerance in COPD
O'Donnell, D. E., Flüge, T., Gerken, F., Hamilton, A., Webb, K., Aguilaniu, B., Make, B., & Magnussen, H. (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00116004 · Cited by 859
Oga, T., Nishimura, K., Tsukino, M., Sato, S., & Hajiro, T. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200206-583oc · Cited by 594
Side effects of intrathecal and epidural opioids
Chaney, M. A. (1995) · Canadian Journal of Anaesthesia · doi:10.1007/bf03011037 · Cited by 562
Piepoli, M., Clark, A. L., Volterrani, M., Adamopoulos, S., Sleight, P., & Coats, A. J. S. (1996) · Circulation · doi:10.1161/01.cir.93.5.940 · Cited by 545
Effect of metabolic products of muscular contraction on discharge of group III and IV afferents
Rotto, D. M., & Kaufman, M. P. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.64.6.2306 · Cited by 524
Cited by
Maltais, F., Decramer, M., Casaburi, R., Barreiro, E., Burelle, Y., Debigaré, R., Dekhuijzen, P. N. R., Franssen, F., Gayan-Ramirez, G., Gea, J., et al. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201402-0373st · Cited by 1,090
Self-citationCritical Power: An Important Fatigue Threshold in Exercise Physiology
POOLE, D. C., BURNLEY, M., VANHATALO, A., ROSSITER, H. B., & JONES, A. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000939 · Cited by 535
Contact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426
Perception of effort in Exercise Science: Definition, measurement and perspectives
Pageaux, B. (2016) · European Journal of Sport Science · doi:10.1080/17461391.2016.1188992 · Cited by 366
The ‘sensory tolerance limit’: A hypothetical construct determining exercise performance?
Hureau, T. J., Romer, L. M., & Amann, M. (2018) · European Journal of Sport Science · doi:10.1080/17461391.2016.1252428 · Cited by 226
“Later studies confirmed this finding and, combined, suggest that participants surpass the critical threshold of peripheral fatigue when group III/IV muscle afferent feedback is pharmacologically attenuated (Amann et al., 2009, 2011; Blain et al., 2016; Gagnon et al., 2012; Sidhu et al., 2014).”
InfluentialInspiratory muscle training reduces diaphragm activation and dyspnea during exercise in COPD
Langer, D., Ciavaglia, C., Faisal, A., Webb, K. A., Neder, J. A., Gosselink, R., Dacha, S., Topalovic, M., Ivanova, A., & O’Donnell, D. E. (2018) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01078.2017 · Cited by 215
“, increases in expiratory and accessory muscle activation, afferent inputs from muscle mechanoreceptors, or metabolic acidosis and increased ergoreceptor activation (16)].”
BackgroundAutonomic responses to exercise: Group III/IV muscle afferents and fatigue
Amann, M., Sidhu, S. K., Weavil, J. C., Mangum, T. S., & Venturelli, M. (2015) · Autonomic Neuroscience · doi:10.1016/j.autneu.2014.10.018 · Cited by 213
“cardiac output) and peripheral (leg blood flow) hemodynamic responses during exercise (4, 5, 7-9, 25).”
BackgroundHuman Vital Signs Detection Methods and Potential Using Radars: A Review
Kebe, M., Gadhafi, R., Mohammad, B., Sanduleanu, M., Saleh, H., & Al-Qutayri, M. (2020) · Sensors · doi:10.3390/s20051454 · Cited by 205
“In addition, exercise-induced dyspnea and chronic obstructive pulmonary disease (COPD) are proven to have strong correlation with BR [10,11].”
Exercise ventilatory inefficiency in mild to end-stage COPD
Neder, J. A., Arbex, F. F., Alencar, M. C. N., O’Donnell, C. D. J., Cory, J., Webb, K. A., & O’Donnell, D. E. (2015) · European Respiratory Journal · doi:10.1183/09031936.00135514 · Cited by 143
Does the Respiratory System Limit Exercise in Mild Chronic Obstructive Pulmonary Disease?
Chin, R. C., Guenette, J. A., Cheng, S., Raghavan, N., Amornputtisathaporn, N., Cortés-Télles, A., Webb, K. A., & O’Donnell, D. E. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201211-1970oc · Cited by 123
Gelabert-Rebato, M., Wiebe, J. C., Martin-Rincon, M., Gericke, N., Perez-Valera, M., Curtelin, D., Galvan-Alvarez, V., Lopez-Rios, L., Morales-Alamo, D., & Calbet, J. A. L. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00740 · Cited by 33
Oliveira, M. F., Zelt, J. T. J., Jones, J. H., Hirai, D. M., O'Donnell, D. E., Verges, S., & Neder, J. A. (2015) · Frontiers in Physiology · doi:10.3389/fphys.2014.00514 · Cited by 20
Metadata
- Authors
- Gagnon, P., Bussières, J. S., Ribeiro, F., Gagnon, S. L., Saey, D., Gagné, N., Provencher, S., & Maltais, F.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-10-01
- Volume
- 186
- Issue
- 7
- Pages
- 606-615
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2134950977
- Cited by
- 160
- References
- 40
- FWCI
- 10.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.